文献速递主动脉疾病

升主动脉假体巨大假性动脉瘤的血管腔内修复:新型Gore®主动脉延长器的超适应证使用

Endovascular Repair of a Huge False Aneurysm From an Ascending Aortic Prosthesis: Off-Label Use of the New Gore® Aortic Extender.
PubMed 文献 · J Endovasc Ther · 2025-04-18

本文报告一例升主动脉假体巨大假性动脉瘤的血管腔内修复。患者10年前因急性A型主动脉夹层行Bentall手术,随访发现11 cm假性动脉瘤,源于Bentall假体上大隐静脉桥血管裂开。因患者明显不适合再次开放手术,超适应证使用Gore®主动脉延长器进行血管腔内治疗。

要点

  • 升主动脉假体巨大假性动脉瘤患者因不适合再手术,可考虑超适应证使用Gore®主动脉延长器行血管腔内修复。
  • Gore®主动脉延长器尺寸适合升主动脉,可作为专用升主动脉腔内移植物未上市时的选择。
  • 开放手术风险过高时,超适应证使用此类腔内装置是有用选择。

核心结论

  • 开放手术风险过高时,超适应证使用Gore®主动脉延长器修复升主动脉假体巨大假性动脉瘤是可行且有技术考量的选择。

研究设计与样本

  • 病例报告,描述1例升主动脉假体巨大假性动脉瘤患者超适应证使用Gore®主动脉延长器行血管腔内修复的可行性与技术考量。

主要发现

  • 患者10年前因急性A型主动脉夹层行Bentall手术,术中因左主干重建后梗阻另行冠状动脉旁路移植。
  • 随访发现11 cm巨大假性动脉瘤,源于Bentall假体上大隐静脉桥血管裂开。
  • 患者明显不适合再次开放手术,遂超适应证使用Gore®主动脉延长器行血管腔内治疗,该延长器为即用型且似完美适合该患者。

临床怎么用

  • 专用升主动脉腔内移植物未即用上市时,开放手术风险过高者可超适应证使用此类腔内装置(作者认为)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

In this case report, we describe the feasibility and technical considerations of an off-label use of the new Gore® Aortic Extender (W.L. Gore & Associates), which is part of the Gore® TAG® Thoracic Branch Endoprosthesis (W.L. Gore & Associates), to repair a huge false aneurysm originating from an ascending aortic prosthesis. The patient's medical history reported an acute type A aortic dissection 10 years ago, for which he was treated with a Bentall procedure. This was complicated by obstruction of the left main coronary after it was reconstructed and thus a coronary artery bypass was also performed. During follow-up, a huge false aneurysm of 11 cm was found, caused by a dehiscent saphenous vein graft on the Bentall prosthesis. Since the patient was clearly not fit for redo surgery, we decided to treat this patient endovascularly with the Gore® Aortic Extender (W.L. Gore & Associates). This cuff has recently been introduced and is off-the-shelf available and seemed to fit perfectly in this patient.Clinical impactWith the introduction of the new, Gore® TAG® Thoracic Branch Endoprosthesis (W.L. Gore & Associates), a very short endoprosthesis became available for proximal extension of the Thoracic Branch Endoprosthesis. This graft, the Gore® Aortic Extender (W.L. Gore & Associates) seems to come in favorable sizes for the ascending aorta. As long as dedicated endoprosthesis for the ascending aorta are not off-the-shelf availabe, off-label use of such endovascular devices is an useful option whenever open surgery seems too high risk.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ko K, Geuzebroek G, Geeraedts T, et al. Endovascular Repair of a Huge False Aneurysm From an Ascending Aortic Prosthesis: Off-Label Use of the New Gore® Aortic Extender. J Endovasc Ther. 2025. PMID: 40249220. doi:10.1177/15266028251333688

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。