文献速递慢性静脉疾病

二维DSA与三维DSA评估髂静脉狭窄的有效性:一项多中心前瞻性研究

Effectiveness of 2D-DSA and 3D-DSA in the Evaluation of Iliac Vein Stenosis: A Multicenter Prospective Study.
PubMed 文献 · J Endovasc Ther · 2025-03-17

本研究以多排CT静脉造影(MDCTV)为参考标准,比较二维DSA与三维DSA测量髂静脉狭窄的敏感性。103例CEAP 3级及以上慢性静脉功能不全患者来自三个中心,均同时接受2D-DSA和3D-DSA检查。3D-DSA在狭窄程度50%-70%组及中央型、外侧型狭窄中准确性优于2D-DSA,且造影剂用量和曝光时间显著减少。

要点

  • 在狭窄50%-70%组,3D-DSA敏感性90.48%高于2D-DSA的78.69%,准确性差异有统计学意义(p=0.019)。
  • 中央型狭窄中3D-DSA准确性93.88%显著高于2D-DSA的77.55%(p=0.021)。
  • 3D-DSA检查时造影剂用量和曝光时间显著减少(p<0.05),对肾功能无明显影响。

核心结论

  • 无论髂静脉狭窄程度或类型如何,3D-DSA对狭窄诊断和评估的敏感性均优于2D-DSA,在非中央型狭窄中尤为明显。
  • 作者认为3D-DSA可在诊断和治疗中替代CTV,提供新的诊疗策略。

研究设计与样本

  • 多中心前瞻性研究,纳入2020年1月至2023年1月三个中心共103例CEAP 3级及以上慢性静脉功能不全患者,均经腹部血管超声和MDCTV阳性后入院。
  • 所有患者住院期间同时接受2D-DSA和3D-DSA检查,图像评估采用双盲严谨流程。
  • 按CTV狭窄程度分为A组(50%-70%)和B组(>70%),按髂静脉受压形态分为中央型、外侧型和部分阻塞型,基于上述分类对各诊断方法进行有效性分析。

主要发现

  • 以MDCTV为参考标准,A组2D-DSA敏感性78.69%、3D-DSA敏感性90.48%;B组2D-DSA敏感性93.44%、3D-DSA敏感性97.62%。
  • A组3D-DSA准确性显著高于2D-DSA(p=0.019),B组差异无统计学意义(p=0.360)。
  • 中央型、外侧型、部分阻塞型2D-DSA准确性分别为77.55%、69.70%、95.24%;3D-DSA准确性分别为93.88%、93.94%、100%。
  • 中央型组3D-DSA准确性显著高于2D-DSA(p=0.021);外侧型组两种方法准确性差异无统计学意义(p=0.011);部分阻塞型组差异无统计学意义(p=1.000)。
  • 3D-DSA造影过程中造影剂用量和曝光时间均显著减少(p<0.05),对肾功能无明显影响。

临床怎么用

  • 作者认为3D-DSA可在诊断和治疗中替代CTV,提供新的诊疗策略。
  • 对于临床医生,3D-DSA在临床实践中提供更全面详细的评估,有助于更精准地诊断和治疗该病。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the sensitivity of measuring iliac vein stenosis using two-dimensional digital subtraction angiography (2D-DSA) and three-dimensional digital subtraction angiography (3D-DSA), with multidetector computed tomography venography (MDCTV) as the reference standard. METHODS: Between January 2020 and January 2023, a total of 103 patients suffered from chronic venous insufficiency symptoms categorized as CEAP Level 3 or above were included from three centers. These patients were admitted to our hospital after abdominal vascular ultrasound and MDCTV positivity. During hospitalization, all patients underwent both 2D-DSA and 3D-DSA procedures simultaneously. Ensure double-blind and rigorous evaluation process when evaluating images. All patients were categorized into two groups based on the degree of CTV stenosis: Group A (50%-70%) and Group B (>70%). Considering the morphology of iliac vein compression, all patients were categorized into three groups: central, lateral, and partial obstruction. Subsequently, the effectiveness analysis was performed for each diagnostic method based on the aforementioned classification. RESULTS: With MDCTV as the reference standard, in Group A, the sensitivity of 2D-DSA and 3D-DSA is 78.69% and 90.48%, respectively. In Group B, the sensitivity of 2D-DSA and 3D-DSA is 93.44% and 97.62%, respectively. In Group A, the accuracy of 3D-DSA is significantly higher than that of 2D-DSA (p = 0.019). However, there is no statistically significant difference in Group B (p = 0.360). The accuracy rates for central, lateral, and partial obstruction using 2D-DSA are, respectively, 77.55%, 69.70%, and 95.24%. The accuracy rates for central, lateral, and partial obstruction using 3D-DSA are, respectively, 93.88%, 93.94%, and 100%. In central group, the accuracy of 3D-DSA is significantly higher than that of 2D-DSA (p = 0.021). In lateral group, no significant difference was observed between the accuracy obtained by both methods (p = 0.011). Similarly, no significant difference was found in partial obstruction group (p = 1.000). During the angiography procedure using 3D-DSA, a significant reduction was observed in both contrast agent quantity and exposure time (p < 0.05) without any apparent effects on renal function. CONCLUSION: Regardless of the degree or type of iliac vein stenosis, 3D-DSA exhibits superior sensitivity compared to 2D-DSA for the diagnosis and evaluation of stenosis. Particularly in instances of noncentral stenosis, 3D-DSA outperforms 2D-DSA.Clinical ImpactThis will provide new insights for the clinical diagnosis and treatment of iliac vein compression syndrome (IVCS), significantly enhancing the diagnostic accuracy of IVCS. For clinicians, three-dimensional digital subtraction angiography (3D-DSA)offers a more comprehensive and detailed assessment in clinical practice, leading to more precise diagnosis and treatment of the disease. The efficacy of two-dimensional digital subtraction angiography (2D-DSA) in treating IVCS is significantly compromised without the guidance from computed tomography venography (CTV). We consider that 3D-DSA can replace CTV in both diagnosis and treatment, providing a new diagnostic and therapeutic strategy.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Luan J, Li Y, Zhang R, et al. Effectiveness of 2D-DSA and 3D-DSA in the Evaluation of Iliac Vein Stenosis: A Multicenter Prospective Study. J Endovasc Ther. 2025. PMID: 40094268. doi:10.1177/15266028251326768

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。