足部加速时间识别外周动脉疾病的诊断试验准确性
这项多中心横断面研究在4个中心连续纳入临床疑似外周动脉疾病(PAD)的受试者,以彩色多普勒超声为参考标准,评估足部加速时间(PAT)识别PAD的诊断准确性。共纳入188名受试者(227条肢体),PAT各测量值的曲线下面积为0.71至0.77,取肢体最差PAT值时AUC为0.79(0.74-0.85)。作者认为PAT具有可接受的诊断准确性,诊断阈值可能需修订为>85 ms。
要点
- 在临床疑似PAD人群中,取肢体最差PAT值的AUC为0.79(0.74-0.85),高于各单支足部动脉的PAT测量值。
- PAT用于识别PAD的阳性预测值为0.81(0.57-0.89),阴性预测值为0.66(0.57-0.75)。
- 作者认为PAT诊断PAD的阈值可能需修订为>85 ms,以优化该检查识别PAD的性能。
核心结论
- 在临床疑似PAD人群中,PAT作为识别PAD的评估工具具有可接受的诊断试验准确性。
- 全部5项PAT测量值与趾压及趾臂指数(TBI)的准确性相似,但取肢体最差PAT值时诊断准确性在所有PAT测量值中最高。
- 作者认为PAT诊断PAD的阈值可能需修订为>85 ms,以优化该检查识别PAD的性能。
研究设计与样本
- 多中心横断面研究,旨在估计诊断试验准确性;在4个中心通过连续抽样招募临床疑似PAD的受试者。
- 由一名血管超声技师测量彩色多普勒超声(参考标准)与趾臂指数(TBI),由另一名对全部其他测量设盲的血管超声技师在同一肢体上测量PAT。
- PAD定义为从远端主动脉至足部任一血管狭窄>50%。
- 共纳入188名受试者(227条肢体),平均年龄71岁(标准差10,范围43-93),女性56名(29.8%),其中133条肢体(70.7%)存在PAD(59%),61名(32.4%)为间歇性跛行患者。
主要发现
- PAT的曲线下面积:足底外侧动脉0.72(0.65-0.79),足底内侧动脉0.72(0.65-0.79),足背跖动脉0.77(0.70-0.84),弓状动脉0.71(0.64-0.78),足底深动脉0.73(0.67-0.80)。
- 取肢体最差PAT值识别PAD的AUC为0.79(0.74-0.85),阳性预测值为0.81(0.57-0.89),阴性预测值为0.66(0.57-0.75)。
- 趾臂指数(TBI)的AUC为0.78(0.71-0.85),踝臂指数(ABI)的AUC为0.70(0.62-0.77)。
关键数值与推荐
- 对全部PAT值估计了敏感性、特异性、阳性预测值、阴性预测值及阳性与阴性似然比,并生成受试者工作特征曲线。
- 作者认为PAT诊断PAD的阈值可能需修订为>85 ms,以优化该检查识别PAD的性能。
临床怎么用
- 作者认为PAT作为识别临床疑似PAD人群PAD的评估工具具有可接受的诊断试验准确性。
- 作者认为全部5项PAT测量值与趾压及TBI的准确性相似,取肢体最差PAT值时诊断准确性最高。
- 作者认为PAT诊断PAD的阈值可能需修订为>85 ms,以优化该检查识别PAD的性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Pedal acceleration time (PAT) is a novel method of using diagnostic ultrasound to evaluate the haemodynamic characteristics of pedal arteries and has potential as an adjunctive vascular testing method. The primary objective of this study was to assess the diagnostic accuracy of PAT in identifying peripheral artery disease (PAD) in a population with clinically suspected PAD. METHODS: This was a multicentre cross sectional study to estimate the diagnostic test accuracy. Participants with clinically suspected PAD were recruited via consecutive sampling at four centres. Colour duplex ultrasound (reference standard) and toe brachial index (TBI) were measured by a vascular sonographer. A second vascular sonographer, blinded to all other measures, conducted the PAT measurements on the same limb. PAD was defined as a > 50% stenosis in any vessel from the distal aorta to the foot. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios were estimated for all PAT values. Receiver operating characteristic curves were also generated. RESULTS: One hundred and eighty-eight participants (227 limbs) were recruited, with a mean age of 71 years (standard deviation 10, range 43 - 93) with 56 women (29.8%) including 133 (70.7) limbs having PAD (59%) and 61 (32.4%) claudicants. Area under the curve for PAT: lateral plantar artery 0.72 (0.65 - 0.79), medial plantar artery 0.72 (0.65 - 0.79), dorsal metatarsal artery 0.77 (0.70 - 0.84), arcuate artery 0.71 (0.64 - 0.78), and deep plantar artery 0.73 (0.67 - 0.80). Utilising the worst case PAT measure for the limb for identifying PAD had an AUC of 0.79 (0.74 - 0.85) and positive and negative predictive values of 0.81 (0.57 - 0.89) and 0.66 (0.57 - 0.75), respectively. Area under the curve for the toe brachial index was 0.78 (0.71 - 0.85) and that of ankle brachial index was 0.70 (0.62 - 0.77). CONCLUSION: PAT had an acceptable diagnostic test accuracy as an assessment tool to identify PAD in a population with clinically suspected PAD. All five measures yielded similar accuracy to toe pressure and TBI; however, using the worst case PAT value yielded the highest diagnostic test accuracy of all PAT measures. The PAT diagnostic threshold for the presence of PAD may be revised to > 85 ms to optimise the performance of the test for the identification of PAD.
引用
- Sommerset J, Teso D, Mills JL, et al. Diagnostic Test Accuracy of Pedal Acceleration Time to Identify Peripheral Artery Disease. Eur J Vasc Endovasc Surg. 2025. PMID: 40086614. doi:10.1016/j.ejvs.2025.03.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。