文献速递主动脉疾病内脏/肾动脉与血管畸形

使用电化导丝技术在分支桥接支架内创建原位开窗

Use of the Electrified Wire Technique for In Situ Fenestration Creation Within a Branch Bridging Stent.
PubMed 文献 · J Endovasc Ther · 2025-03-13

本文报告一例73岁男性胸腹主动脉瘤患者,在分支腔内修复术中因桥接支架脱载导致腹腔干被意外覆盖,遂采用电化导丝技术在覆盖腹腔干/肠系膜上动脉共干的桥接支架内创建原位开窗以保留腹腔干通畅,6个月CT血管造影确认靶血管通畅。作者认为该技术可作为早期靶血管侧支意外覆盖时原位开窗的补救措施。

要点

  • 电化导丝技术可用于分支腔内修复术中桥接支架意外覆盖靶血管后的原位开窗补救。
  • 本例在腹腔干/肠系膜上动脉共干(解剖变异)的桥接支架内创建原位开窗,并以裸金属支架行腹腔干血运重建。
  • 术后6个月CT血管造影确认靶血管通畅。

核心结论

  • 作者认为电化导丝技术可用于早期靶血管侧支意外覆盖时创建原位开窗的补救。

研究设计与样本

  • 本文为技术报告,报告1例73岁男性胸腹主动脉瘤患者的病例。

主要发现

  • 患者既往因B型主动脉夹层接受胸主动脉腔内修复及PETTICOAT技术治疗,此次表现为68 mm的V型胸腹主动脉瘤。
  • 患者存在肠系膜上动脉与腹腔干共干的解剖变异,在既往开放手术尝试失败后,选择三分支定制装置(2个肾分支和1个用于肠系膜上动脉/腹腔干共干的分支)。
  • 支架移植物释放及靶血管插管顺利,直至因桥接支架脱载发生腹腔干意外覆盖。
  • 使用电化导丝技术在覆盖腹腔干/肠系膜上动脉共干的桥接支架内创建原位开窗以保留腹腔干通畅,并以裸金属支架行腹腔干血运重建。
  • 肾动脉按计划插管并桥接,术后6个月CT血管造影确认靶血管通畅。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To present the use of the electrified wire technique as bailout for target vessel (TV) branch preservation after unintended coverage by a bridging stent during branched endovascular repair (bEVAR). TECHNIQUE: A 73-year-old male, previously treated with thoracic endovascular aortic repair and Provisional Extension to Induce Complete Attachment Technique (PETTICOAT) for type B aortic dissection, presented with a 68 mm type V thoracoabdominal aortic aneurysm. The patient presented an anatomic variation with a common trunk for the superior mesenteric artery (SMA) and celiac artery (CA). After a previously failed open surgical attempt, a triple-branch custom-made device (2 renal branches and 1 for the SMA/CA trunk) was chosen. Endograft deployment and TV catheterization were uneventful, until an unintended coverage of the CA occurred, due to bridging stent unmount. Using the electrified wire technique, an in situ fenestration was created into the CA/SMA trunk covered bridging stent to preserve CA patency. A bare metal stent was used for CA revascularization. Renal arteries were catheterized and bridged as planned. The 6-month computed tomography angiography confirmed TV patency. CONCLUSION: The electrified wire technique may be used as bailout for in situ fenestration creation in unintended coverage of early TV side-branches.Clinical ImpactAnatomic variations may increase the technical complexity of branched endovascular aortic repair while technical pitfalls related to target vessel preservation may demand the application of bailout techniques. In this case, the electrified wire technique was used to create an in situ fenestration within the bridging stent of a celiac artery (CA) and superior mesenteric artery common trunk (anatomic variation), after bridging stent unmount during advancement and CA unintended coverage.

来源:J Endovasc Ther,查看原文。版权归原作者所有。