文献速递静脉血栓栓塞

下腔静脉的影像学特征及其滤器置入后反应的 单中心回顾性研究

Radiographic Characterization of Inferior Vena Cava and Its Reaction Following Filter Placement: A Single-Center Retrospective Study.
PubMed 文献 · J Endovasc Ther · 2025-02-21

单中心回顾性研究纳入2018年9月至2023年6月置入纺锤形滤器前后均行CTV的70例患者,分析下腔静脉直径与形态变化及并发症。置入后下腔静脉趋于类圆形,短轴扩张大于长轴,滤器周围血栓多见于短轴前后壁。

要点

  • 70例中1型下腔静脉52例(74.3%),2型11例(15.7%),3型4例(5.7%),4型3例(4.3%),无5型。
  • 置入后下腔静脉形态趋于类圆形,Lin一致性相关系数CCC为0.870,方位显著改变。
  • 1、3、4型患者短轴平均直径增加近1.5倍,短轴扩大率大于长轴。

核心结论

  • 置入纺锤形滤器后下腔静脉形态趋于类圆形,短轴直径变化大于长轴,滤器相关血栓多发生于短轴方向。

研究设计与样本

  • 单中心回顾性研究,纳入2018年9月至2023年6月置入纺锤形滤器前后均行下腔静脉CT静脉造影的合格患者70例。
  • 分析基线数据、滤器置入前后下腔静脉直径与方位、下腔静脉扩大率及相关并发症。

主要发现

  • 70例中1型下腔静脉52例(74.3%),2型11例(15.7%),3型4例(5.7%),4型3例(4.3%),无5型。
  • 置入后下腔静脉形态趋于类圆形,Lin一致性相关系数CCC为0.870,方位显著改变。
  • 1、3、4型患者短轴平均直径增加近1.5倍(95%CI=-7.77至-5.83,p<0.001),长轴仅轻度扩张至初始大小(p>0.05)。
  • 短轴直径的下腔静脉扩大率大于长轴(95%CI=40.31至65.12,p<0.001)。
  • 滤器周围区域血栓22例(31.4%),其中前壁或后壁14例(20.0%),侧壁5例(7.1%),滤器中央3例(4.3%);前后壁血栓发生率高于侧壁(20.0% vs 7.1%,p=0.014)。

临床怎么用

  • 作者指出,围术期优化下腔静脉尺寸和置入后严密监测对改善患者结局至关重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To classify the radiographic characterization of the inferior vena cava (IVC) diameter, as well as to quantitatively describe the dimensional alternations in response to variations in filter placement, using cross-sectional computer tomographic venography (CTV) imaging. METHODS: A single-center retrospective study was conducted on eligible patients who underwent CTV of IVC both before and after the placement of spindle-shaped filters, from September 2018 to June 2023. Baseline data, IVC diameter and orientation pre- and post-filter placement, IVC enlargement rate, and related complications were analyzed. RESULTS: A total of 70 eligible patients were included, 52 (74.3%) with type 1 IVC, 11 (15.7%) with type 2, 4 (5.7%) with type 3, 3 (4.3%) with type 4, and none with type 5. An accompanying morphological alteration turned IVC into a quasi-round shape with Lin CCC of 0.870, and orientation was significantly altered after filter placement. In patients with type 1, 3, and 4 IVCs, the mean diameter of the IVC increased almost 1.5-fold in the minor axis (95% confidence intervals [CIs]=-7.77 to -5.83, p<0.001), while only a slight expansion of the major axis to its initial size (p>0.05). Greater IVC enlargement rate was seen in the diameter of the minor axis than in the major axis (95% CI=40.31 to 65.12, p<0.001). Notably, regional clots around the filter were found in 22 (31.4%) patients. Among them, 14 (20.0%) were located on the anterior or posterior walls of caval minor axis, 5 (7.1%) in the lateral walls, and 3 (4.3%) in the central part of the IVC filter. Patients exhibited a higher incidence of clots on anterior and posterior walls compared to lateral wall (20.0% vs 7.1%, p=0.014). CONCLUSION: The morphology of IVC shifted toward an approximated as circles after filter placement, with greater diameter changes seen in the minor axis compared to the major axis, where filter-related thrombosis most occurs.Clinical ImpactThe findings of this study offer insights into the biomechanical interaction between the inferior vena cava (IVC) and spindle-shaped filters, highlighting the anisotropic dimensional changes triggered by filter placement. The pronounced expansion along the minor axis, where filter-related thrombosis was more frequently observed, underscores a previously underrecognized risk factor for post-implantation complications. These results indicate that perioperative optimization of IVC dimensions and vigilant post-placement monitoring are crucial for improving patient outcomes.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Gong M, Jiang R, Xu S, et al. Radiographic Characterization of Inferior Vena Cava and Its Reaction Following Filter Placement: A Single-Center Retrospective Study. J Endovasc Ther. 2025. PMID: 39981907. doi:10.1177/15266028251319137

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。