标准锁骨下分支腔内移植物在既往Zone 2胸主动脉腔内修复术后的解剖适用性
单中心回顾性临床前适用性研究纳入1999至2023年517例中102例Zone 2着陆的胸主动脉腔内修复术患者中的92例,评估Gore胸主动脉分支腔内假体按制造商使用说明的解剖适用性。70例(76.1%)适用,扩展适用性分析增至77例(83.6%);主动脉着陆区直径(OR=0.83,95%CI 0.75-0.93,p=0.001)、着陆区长度(OR=1.32,95%CI 1.14-1.53,p<0.001)及锁骨下动脉长度(OR=1.18,95%CI 1.07-1.31,p=0.001)与适用性几率显著相关。
要点
- 70例(76.1%)符合制造商使用说明的解剖适用标准,扩展适用性分析增至77例(83.6%)。
- 87%的适用患者可使用5种主动脉组件治疗,4种侧支构型适配89.2%的适用病例。
- 椎前左锁骨下动脉长度短和近端主动脉着陆区短是最常见解剖排除原因。
核心结论
- Gore胸主动脉分支腔内假体对超过四分之三的病例解剖适用。
- 有限数量的支架移植物构型可适配相当数量患者,为这款即用型器械的广泛应用铺平道路。
研究设计与样本
- 单中心、回顾性、临床前适用性研究,1999至2023年连续治疗517例,其中102例着陆于Zone 2,最终纳入92例患者。
- 适用性依据制造商使用说明定义,并评估扩展适用性(纳入因左锁骨下动脉测量初始排除的患者)。
主要发现
- 70例(76.1%)适用,扩展适用性分析增至77例(83.6%)。
- 87%的适用患者可使用5种主动脉组件治疗,4种侧支构型适配89.2%的适用病例。
- 椎前左锁骨下动脉长度短和近端主动脉着陆区短是最常见解剖排除原因。
- 主动脉着陆区直径(OR=0.83,95%CI 0.75-0.93,p=0.001)、着陆区长度(OR=1.32,95%CI 1.14-1.53,p<0.001)及锁骨下动脉长度(OR=1.18,95%CI 1.07-1.31,p=0.001)与适用性几率显著相关。
关键数值与推荐
- 适用性判定依据制造商使用说明。
- 扩展适用性分析纳入因左锁骨下动脉测量初始排除的患者。
临床怎么用
- 有限的支架移植物构型可适配相当部分队列,可帮助临床医生制定与该器械相关的腔内移植物库存。
- 为这款即用型器械的广泛应用铺平道路。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Purpose: To evaluate the anatomical suitability of the Gore Thoracic Branch Endoprosthesis in patients treated with thoracic endovascular aortic repair in landing zone 2. Materials and methods: A total of 517 cases were consecutively treated between 1999 and 2023, of which 102 were deployed in landing zone 2. A total of 92 patients were included in a single-center, retrospective, preclinical suitability study. The suitability for the investigational device was defined according to the manufacturer's instructions for use. Extended suitability was also evaluated, including patients initially excluded for left subclavian artery measurements. Secondary outcomes were suitable and non-suitable patient comparisons, analysis of exclusion causes, and anatomical characteristics associated with suitability. A logistic regression model evaluated associations between baseline anatomical characteristics and non-suitability. Results: Seventy patients (76.1%) were suitable for implantation, which increased to 77 (83.6%) when analyzing extended suitability. Eighty-seven percent of suitable patients could have been treated with 5 aortic components, and 4 side branch configurations fitted 89.2% of suitable cases. A short prevertebral left subclavian artery length and a short proximal aortic landing zone were the most common causes of anatomical exclusion. The aortic landing zone diameter (odds ratio [OR]=0.83, 95% confidence interval [CI]=0.75-0.93, p=0.001) and length (OR=1.32, 95% CI=1.14-1.53, p<0.001) along with subclavian length (OR=1.18, 95% CI=1.07-1.31, p=0.001) were significantly associated with the odds of suitability. Conclusions: The Gore Thoracic Branch Endoprosthesis was anatomically suitable for more than 3 quarters of cases. A limited number of stent-graft configurations could fit the cohort in a remarkable number of patients, paving the way for wide application of this off-the-shelf device.Clinical ImpactThe present paper highlighted a significant feasibility rate for the Gore Thoracic Branch Endoprothesis among patients previously treated with TEVAR and proximal landing in zone. The limited number of stent-graft configurations that could have been implanted in a considerable portion of our cohort could help clinicians to develop a proper endovascular inventory related to this device, paving the way for its wide application.
引用
- Leone N, Andreoli F, Bartolotti LAM, et al. Anatomical Suitability of a Standard Subclavian Branched Endograft in Previous Zone 2 Thoracic Endovascular Aortic Repair. J Endovasc Ther. 2025. PMID: 39957253. doi:10.1177/15266028251316153
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。