文献速递主动脉疾病内脏/肾动脉与血管畸形

部分展开技术在T-branch腔内修复狭窄或严重成角内脏旁主动脉的复杂主动脉及胸腹主动脉动脉瘤中的应用

T-branch by partial deployment technique in the endovascular repair of complex aortic and thoracoabdominal aneurysms with narrow or severe angulated para-visceral aorta.
PubMed 文献 · J Vasc Surg · 2025-01-10

作者认为该技术在此类解剖条件下似乎安全有效,并提示可能扩大紧急情况下外分支的解剖可行性标准。

要点

  • 128条靶动脉中111条(87%)在远端捕获主动脉支架下完成插管/支架置入,靶动脉不稳定率2%(3/128)。
  • 1年免于靶动脉不稳定为91%,30天死亡2例(6%),随访中位14个月。

核心结论

  • T-branch联合部分展开技术在处理狭窄或严重成角内脏旁主动脉的复杂主动脉瘤/胸腹主动脉瘤中似乎安全有效,技术成功率和中期靶动脉不稳定结果令人满意,提示可能扩大紧急情况下外分支的解剖可行性标准。

研究设计与样本

  • 分析2021至2023年所有连续接受T-branch(Cook Medical)联合部分展开技术紧急腔内修复复杂主动脉瘤和胸腹主动脉瘤的患者,共33例。

主要发现

  • 33例中,失败腔内修复术后I型内漏6例(18%),近肾/肾旁动脉瘤9例(28%),夹层后胸腹主动脉瘤6例(18%),退行性胸腹主动脉瘤12例(36%)。
  • 内脏旁主动脉 lumen 直径中位23 mm(四分位距19-27 mm),10例(30%)存在严重成角。
  • 128条靶动脉中111条(87%)在远端捕获主动脉支架下完成插管/支架置入;盆腔/下肢缺血时间中位120分钟(四分位距90-150分钟)。
  • 技术成功所有患者均实现;1例(3%)发生脊髓缺血,无卒中病例;30天内靶动脉不稳定1/128(0.8%),再干预1/33(3%),死亡2例(6%)。
  • 随访中位14个月(四分位距6-22个月);6个月时发生双侧肾动脉闭塞1例(3%);无肠系膜上动脉或腹腔干事件,总体靶动脉不稳定率2%(3/128)。

关键数值与推荐

  • 狭窄内脏旁主动脉定义为NPA<25 mm,严重成角定义为APA>60°。

临床怎么用

  • 作者认为,T-branch联合部分展开技术在狭窄或严重成角内脏旁主动脉的复杂主动脉瘤/胸腹主动脉瘤紧急腔内修复中似乎安全有效,并提示可能扩大紧急情况下外分支的解剖可行性标准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA <25 mm) or severely angulated (APA >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT. METHODS: All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook Medical) and PDT from 2021 to 2023 were analyzed. Technical success (TS), 30-day mortality, and TA instability within 30 days and 1 year, as well as reinterventions, were assessed as primary endpoints. Time of intraoperative pelvic/lower limb ischemia, spinal cord ischemia (SCI), and perioperative stroke were assessed as secondary endpoints. RESULTS: Thirty-three cases were analyzed. There were six type I endoleaks (18%) in failed endovascular aortic repair, nine juxta/para-renal aneurysms (28%), six post-dissection TAAAs (18%), and 12 degenerative TAAAs (36%), respectively. The median para-visceral aortic lumen diameter was 23 mm (interquartile range [IQR], 19-27 mm), and 10 cases (30%) had APA. Of 128 TAs, 111 (87%) were cannulated/stented with distally captured aortic graft. The median time of pelvic/lower limb ischemia was 120 minutes (IQR, 90-150 minutes). TS was achieved in all patients. One patient (3%) suffered SCI, and there were no cases of stroke. An asymptomatic renal artery occlusion was detected at postoperative imaging, which was recanalized by thrombus-aspiration/relining. This was the only case of TA instability (1/128; 0.8%) and reintervention (1/33; 3%) within 30 days. Two patients (6%) died within 30 days. Median follow-up was 14 months (IQR, 6-22 months). One case (3%) of bilateral renal artery occlusion occurred at 6 months. No superior mesenteric artery or celiac trunk events occurred, with an overall TA instability rate of 2% (3/128). Eighteen patients (55%) completed the radiologic follow-up at 1 year with no new cases of TA instability. Freedom from TA instability was 91% at 1 year. CONCLUSIONS: T-branch by PDT seems to be safe and effective in the management of c-AAAs/TAAAs with NPA or APA. Results were satisfactory in terms of TS and mid-term TA instability, suggesting a possible enlargement of the anatomical feasibility criteria for outer branches in urgent cases.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Gallitto E, Faggioli G, Lodato M, et al. T-branch by partial deployment technique in the endovascular repair of complex aortic and thoracoabdominal aneurysms with narrow or severe angulated para-visceral aorta. J Vasc Surg. 2025. PMID: 39800118. doi:10.1016/j.jvs.2025.01.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。