开发基于临床与超声参数的列线图模型预测股浅动脉支架置入术后再狭窄
该回顾性研究纳入2018年1月1日至2022年1月1日在本院接受股浅动脉自膨式裸镍钛支架治疗的381例患者,随机分为训练队列266例和验证队列115例。通过logistic回归筛选出性别、靶斑块回声、术前动脉流出道评分、术前腘动脉流速、病变长度和残余直径等再狭窄危险因素并构建列线图,内部验证AUC为0.82(95%CI:0.77-0.87),外部验证AUC为0.70(95%CI:0.60-0.79),校准曲线和决策曲线显示模型具有良好的校准能力和临床实用性。
要点
- 性别、靶斑块回声、术前动脉流出道评分、术前腘动脉流速、病变长度和残余直径为股浅动脉支架术后再狭窄的危险因素。
- 列线图模型内部验证AUC为0.82(95%CI:0.77-0.87),外部验证AUC为0.70(95%CI:0.60-0.79)。
- 校准曲线显示模型校准良好,决策曲线分析显示具有临床实用性。
核心结论
- 该新型列线图预测股浅动脉支架置入术后再狭窄表现出优秀的区分能力、校准能力和临床实用性。
研究设计与样本
- 回顾性研究,纳入2018年1月1日至2022年1月1日在本院接受股浅动脉自膨式裸镍钛支架治疗的381例患者,随机分为训练队列266例和验证队列115例。
主要发现
- 多因素logistic回归显示性别、靶斑块回声、术前动脉流出道评分、术前腘动脉流速、病变长度和残余直径是再狭窄(>50%)的危险因素。
- 内部验证AUC为0.82(95%CI:0.77-0.87),外部验证AUC为0.70(95%CI:0.60-0.79)。
- 校准曲线显示模型校准良好,决策曲线分析显示模型具有临床实用性。
关键数值与推荐
- 再狭窄定义为股浅动脉12个月时狭窄>50%。
- 列线图模型基于性别、靶斑块回声、术前动脉流出道评分、术前腘动脉流速、病变长度和残余直径构建。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Prediction of in-stent restenosis (ISR) is clinically important for patients with peripheral artery disease (PAD) in superficial femoral artery (SFA) who have been treated with stenting. The aim of this study was to construct and validate a predictive model for ISR after SFA stenting based on a series of clinical and ultrasonic parameters. METHODS: This retrospective study included 381 patients who were treated with self-expanding bare nitinol stents in their SFA at our hospital between January 1, 2018, and January 1, 2022. These patients were randomly allocated to a training cohort (266 patients) or a validation cohort (115). Clinical and ultrasonic parameters related to ISR (>50%) in the SFA at 12 months were derived by univariable and multivariable logistic regression analyses to create a nomogram model predictive of risk of ISR. Receiver operating characteristic (ROC) curve analyses were used to assess the recognition ability of the model. A calibration curve was used to evaluate the model's calibration ability, and decision curve analysis was used to validate the nomogram's clinical utility. RESULTS: Logistic regression analyses showed that sex, echogenicity of the target plaque, preoperative arterial runoff score, preoperative popliteal artery flow rate, lesion length, and residual diameter were risk factors for ISR; these parameters were used to construct the nomogram model. Internal and external validation showed that the areas under the ROC curves were 0.82 (95% CI: 0.77-0.87) and 0.70 (95% CI: 0.60-0.79), respectively, suggesting good recognition ability of the model. Additionally, calibration curves for the predictive model indicated good calibration, and the decision curve analysis demonstrated clinical utility of the model. CONCLUSION: This novel nomogram that predicts ISR after SFA stenting demonstrated excellent discriminatory power, calibration capacity, and clinical usefulness.
引用
- Wang Y, Gao M, Zhao X, et al. Development of a Clinical and Ultrasonic Parameter-Based Nomogram Model to Predict Restenosis after Superficial Femoral Artery Stenting. Ann Vasc Surg. 2025. PMID: 39855385. doi:10.1016/j.avsg.2024.12.068
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。