复杂腹主动脉瘤修复中腹腔干动脉纳入采用双宽扇贝形开窗与开窗术的患者结局比较
单中心回顾性分析2013至2020年131例接受开窗分支腔内修复的复杂腹主动脉瘤患者,68例(52%)腹腔干采用双宽扇贝形开窗,63例(48%)采用开窗术。双宽扇贝形开窗组中位腔内手术时间和透视时间更短,两组技术成功率、30天死亡率、主要不良事件、囊腔回缩及腹腔干靶血管不稳定均无显著差异。
要点
- 双宽扇贝形开窗组中位腔内手术时间118分钟,短于开窗组141分钟(P = .006)。
- 双宽扇贝形开窗组中位透视时间64分钟,短于开窗组70分钟(P = .032)。
- 两组技术成功率96% vs 100%(P = .096),30天死亡率0% vs 1.6%(P = .297),均无显著差异。
核心结论
- 在根据内脏段封闭区长度和主动脉退变风险精确选择器械的前提下,双宽扇贝形开窗与开窗术用于腹腔干动脉纳入的围手术期和长期结局相当,技术成功、靶血管不稳定或囊腔回缩均无显著差异。
- 器械设计应根据患者解剖和封闭区决定,因为结局相当。
研究设计与样本
- 本研究为单中心回顾性综述,纳入2013至2020年前瞻性研究性器械豁免试验中接受开窗分支腔内修复的复杂腹主动脉瘤患者。
- 共131例患者,其中男性97例(74%);双宽扇贝形开窗组68例(52%),开窗组63例(48%)。
主要发现
- 两组患者平均年龄均为75.0 ± 7.4岁,人口学特征、心血管危险因素及平均主动脉直径(P = .382)相似。
- 双宽扇贝形开窗组中位腔内手术时间118分钟(四分位距98-154分钟),开窗组141分钟(122-170分钟),P = .006;中位透视时间双宽扇贝形开窗组64分钟(四分位距51-78分钟),开窗组70分钟(61-83分钟),P = .032;对比剂体积无差异(P = .204)。
- 技术成功率双宽扇贝形开窗组96%,开窗组100%(P = .096);双宽扇贝形开窗组有3例患者出现腹腔干动脉部分或完全覆盖。
- 中位主动脉覆盖长度(腹腔干以上)开窗组5.5 cm(四分位距4.5-6.4 cm),双宽扇贝形开窗组3.8 cm(3.5-4.2 cm),P < .001。
- 30天死亡率双宽扇贝形开窗组0%,开窗组1.6%(P = .297);主要不良事件双宽扇贝形开窗组17.6%,开窗组17.5%(P = .978);中位随访42个月(Q1,Q3,25,50),无I A型内漏、主动脉破裂或开放转换;囊腔回缩双宽扇贝形开窗组60%,开窗组67%(P = .449),生存率(P = .859)及腹腔干靶血管不稳定(P = .320)均无差异。
临床怎么用
- 作者认为,基于内脏段封闭区长度和主动脉退变风险精确选择器械时,双宽扇贝形开窗与开窗术结局相当,器械设计应由患者解剖和封闭区决定。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Celiac artery (CA) incorporation during fenestrated-branched aortic aneurysm repair (FB-EVAR) for complex abdominal aortic aneurysms (cAAAs) is typically performed with fenestrations. Double-wide scallops (DWS) can be used when appropriate. We aimed to assess outcomes of patients treated with DWSs for the CA during FB-EVAR for cAAAs. METHODS: This is a single-center retrospective review of patients enrolled in a prospective investigational device exemption trial undergoing FB-EVAR for cAAA from 2013 to 2020. The use of DWS or fenestrations for the management of the CA was selected to optimize seal. Patients with longer lengths of normal caliber aorta between the renal and celiac arteries, and without thoracic aortic ectasia or multifocal thoracic aortic aneurysms, were considered for DWS, whereas those with shorter visceral segment seal zones or thoracic aortic disease were preferentially treated with fenestrations for the CA. End points were morbidity, mortality, technical success, freedom from type IA endoleak, and target vessel instability (TVI). RESULTS: FB-EVAR with CA DWS or fenestration was performed in 131 patients, including 97 males (74%). DWSs were used in 68 patients (52%) and fenestrations in 63 (48%). The mean patient age was 75.0 ± 7.4 years in both groups. Demographics, cardiovascular risk factors, and mean aortic diameter (P = .382) were similar between groups. The median number of incorporated vessels was similar (4; P = .373) between groups. The median endovascular operative time (DWS = 118 minutes [interquartilr range (IQR), 98-154 minutes]; fenestration = 141 minutes [122-170 minutes]; P = .006) and fluoroscopy time (DWS = 64 minutes [IQR, 51-78 minutes]; fenestration = 70 minutes [IQR, 61-83 minutes]; P = .032) were shorter with DWS, with no difference in contrast volume (P = .204). Technical success was 96% with DWS and 100% with fenestrations (P = .096). Three patients with DWS had partial or complete CA coverage. Median aortic coverage (above CA) was higher with fenestrations (fenestration = 5.5 cm [IQR, 4.5-6.4 cm]; DWS = 3.8 cm [IQR, 3.5-4.2 cm]; P < .001). There was no difference in 30-day mortality (DWS = 0%, fenestration = 1.6%; P = .297) or major adverse events (DWS = 17.6% vs fenestration = 17.5%; P = .978). The median follow-up was 42 months [Q1, Q3, 25, 50]. There were no type IA endoleaks, aortic ruptures, or open conversions. There was no difference in sac regression (DWS = 60%, fenestration = 67%; P = .449), survival (P = .859), or CA TVI (P = .320). CONCLUSIONS: FB-EVAR with DWS and fenestrations show comparable perioperative and long-term outcomes without significant differences in technical success, TVI, or sac regression when used with precise device selection based on visceral segment seal zone lengths and risk for aortic degeneration. Device design should be determined by patient anatomy and seal zone given comparable outcomes.
引用
- Cirillo-Penn NC, MacArthur TA, Tenorio ER, et al. Outcomes of patients treated with double-wide scallop vs fenestrations for celiac artery incorporation during repair of complex abdominal aortic aneurysms. J Vasc Surg. 2025. PMID: 39884565. doi:10.1016/j.jvs.2025.01.194
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。