升主动脉包裹联合TEVAR的杂交主动脉弓动脉瘤修复
回顾性分析2013至2024年12例高危主动脉弓动脉瘤患者,接受升主动脉包裹、上主动脉分支去分支化及0区TEVAR。术前升主动脉平均直径47.7 mm,包裹后35.6 mm。30天无卒中,1例死于心脏骤停。作者认为该技术可能是高危患者的一种选择。
要点
- 升主动脉包裹后平均直径由47.7 mm降至35.6 mm,平均密封长度68.5 mm。
- 12例中34支上主动脉分支成功去分支化,完成造影无1型或3型内漏。
- 30天内无卒中,1例死于心脏骤停;平均随访28个月,1例死于不明原因。
核心结论
- 升主动脉包裹联合上主动脉分支去分支化及0区TEVAR,对于开放升主动脉置换高危且近端密封区不适合完全腔内修复的患者,可能是较好的选择。
研究设计与样本
- 回顾性分析本中心2013至2024年主动脉数据库,选取接受升主动脉包裹和TEVAR的高危主动脉弓动脉瘤患者12例,术前、术后及末次CTA分析。
主要发现
- 12例中9例为大型弓部动脉粥样硬化性动脉瘤,3例为随访升主动脉包裹(最初因急性A型夹层行包裹)期间发现夹层性弓部动脉瘤,包裹与TEVAR平均间隔51.5个月。
- 平均年龄72.9岁;3/12例同期行升主动脉包裹和TEVAR(其中2例破裂),其余9例分期进行。
- 包裹前升主动脉平均直径47.7(41.3-57)mm,包裹后35.6(31.9-43)mm;包裹提供平均密封长度68.5(38.4-97.4)mm。
- 共34支上主动脉分支成功去分支化;完成造影无1型或3型内漏;30天内无卒中,1例Horton病患者术后第7天死于心脏骤停。
- 3例需早期再干预(2例再次开胸);平均随访28(1-75)个月,1例出现左椎动脉窃血现象需颈动脉-锁骨下动脉旁路,另1例死于不明原因。
临床怎么用
- 作者认为,该技术可作为开放升主动脉置换高危且近端密封区不适合完全腔内修复的脆弱患者的一种治疗选择。
- 该技术不需要体外循环支持,也不需要主动脉阻断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Management of patients with large aortic arch aneurysms who are considered high risk for frozen elephant trunk technique have been challenging, especially when they have a dilated ascending aorta (AA) that precludes total endovascular branched repair (arch BEVAR). A viable option in our armamentarium is wrapping of the AA (AW), and zone 0 Ishimaru TEVAR. METHODS: Retrospective analysis of our aortic database from 2013 to 2024 to select high-risk patients with aortic arch aneurysm that had an AW and TEVAR. We performed CTA analysis before and after wrapping and TEVAR, and last available CTA. The primary end points were 30-day mortality and stroke. RESULTS: A total of 12 patients had AA wrap and TEVAR, with supra-aortic vessels (SAVs) debranching (open or endovascular). In 9 patients, the indication for treatment was a large arch atherosclerotic aneurysm, and in 3 patients a dissecting arch aneurysm depicted during follow-up of AW initially performed for acute type A dissection (51.5 months on average between the wrap and the TEVAR). Average age was 72.9 years. Ascending aorta wrap and TEVAR were performed concomitantly in 3/12 patients, including 2 patients with rupture. It was staged in the other 9 patients. The average diameter of the AA pre-wrap was 47.7 (41.3-57), and post-wrap 35.6 (31.9-43) mm. The wrap provided an average seal length of 68.5 (38.4-97.4) mm. A total of 34 SAV were successfully debranched. No type 1 or 3 endoleaks were depicted on completion angiogram. Within the first 30 days, no strokes were diagnosed, and 1 patient with Horton disease died of cardiac arrest on postoperative day 7. Three patients required early reinterventions, including redosternotomy in 2 patients. Mean follow-up (FU) was 28 months (1-75). During FU, 1 patient developed a left vertebral artery steal phenomenon requiring a carotid subclavian bypass, and another patient died of an unknown cause. CONCLUSION: Ascending aorta wrap technique with debranching of the SAVs and zone 0 TEVAR might be a good option in patients at high risk for open replacement of the AA and with unfavorable proximal seal zone for a total endovascular repair.Clinical ImpactIn the current study, we describe the treatment of aortic arch aneurysms in patients considered at high risk for open replacement of the aortic arch and also not candidate for complete endovascular arch repair (arch BEVAR). Ascending aorta wrap with surgical or endovascular debranching of SAVs and zone 0 TEVAR was performed in 12 patients with favorable outcomes. It should thus be considered a treatment option in this subset of fragile patients with unfavorable proximal seal zone for total endovascular repair. This technique does not require cardiopulmonary bypass (CPB) support, neither aortic cross-clamping.
引用
- Shazly OE, Porez F, Ramadan R, et al. Hybrid Arch Aneurysm Repair With Ascending Aortic Wrap and TEVAR. J Endovasc Ther. 2025. PMID: 39811954. doi:10.1177/15266028241312572
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。