文献速递静脉血栓栓塞

多学科质量改进项目改善患者随访与滤器取出率

A Multidisciplinary Quality Improvement Project Leads to Improved Patient Follow-up and Filter Retrieval Rate.
PubMed 文献 · Ann Vasc Surg · 2024-12-26

本研究纳入2021年3月至2023年3月在本中心连续放置可取出滤器的患者,分为改进前组(2022年4月前,n=81)和改进后组(2022年4月后,n=77)。改进前组分析失访危险因素,并比较两组滤器取出率。结果显示急性脑出血和转诊科室未要求随访是失访的独立危险因素,质量改进项目提高了随访和滤器取出率。

要点

  • 急性脑出血(OR=5.745;95%CI:1.471-22.434)和转诊科室未要求随访(OR=3.435;95%CI:1.035-11.398)是失访的独立危险因素。
  • 改进后组滤器取出率94.8%高于改进前组69.1%(P<0.001),失访率5.2%低于改进前组30.9%(P<0.001)。
  • 改进前组滤器取出时下腔静脉穿孔发生率9.6%高于改进后组0(P=0.019)。

核心结论

  • 急性脑出血和转诊科室未要求随访是其他科室住院患者失访的独立危险因素。
  • 本中心的质量改进项目改善了其他科室住院患者的随访和下腔静脉滤器取出率。

研究设计与样本

  • 连续纳入2021年3月至2023年3月在本中心接受可取出滤器放置的患者。
  • 分为改进前组(2022年4月前;n=81)和改进后组(2022年4月后;n=77)。
  • 在改进前组中评估失访危险因素,并比较两组滤器取出率。

主要发现

  • 急性脑出血(OR=5.745;95%CI:1.471-22.434)和转诊科室未要求随访(OR=3.435;95%CI:1.035-11.398)是失访的独立危险因素。
  • 改进后组滤器取出率94.8%高于改进前组69.1%(P<0.001)。
  • 改进后组失访率5.2%低于改进前组30.9%(P<0.001)。
  • 改进前组滤器取出时下腔静脉穿孔发生率9.6%高于改进后组0(P=0.019)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To identify risk factors for loss to follow-up after inferior vena cava (IVC) filter placement in inpatients of other departments (IODs) and to determine whether a quality improvement project launched at our institution in April 2022 improved follow-up and filter retrieval rates in these patients. METHODS: Consecutive patients who underwent retrievable filter placement at our institution between March 2021 and March 2023 were included in this study. Patients were divided into preimprovement (before April 2022; n = 81) and postimprovement (after April 2022; n = 77) groups. Risk factors for loss to follow-up were assessed in the preimprovement group, and filter retrieval rates were compared between groups. RESULTS: Acute cerebral hemorrhage (OR = 5.745; 95% CI: 1.471-22.434) and lack of requirement for follow-up by the referring department (OR = 3.435; 95% CI: 1.035-11.398) were identified as independent risk factors for loss to follow-up. The filter retrieval rate was higher in the postimprovement group (94.8%) than in the preimprovement group (69.1%; P < 0.001). The rate of loss to follow-up was lower in the postimprovement group (5.2%) than in the preimprovement group (30.9%; P < 0.001). The preimprovement group had a higher incidence of IVC perforation (9.6%) than the postimprovement group (0; P = 0.019) at the time of filter retrieval. CONCLUSION: Acute cerebral hemorrhage and lack of requirement for follow-up by the referring department are independent risk factors for loss to follow-up among IODs. The quality improvement project at our institution improved follow-up and IVC filter retrieval rates in IODs.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Qin L, Tian F, Wang K, et al. A Multidisciplinary Quality Improvement Project Leads to Improved Patient Follow-up and Filter Retrieval Rate. Ann Vasc Surg. 2024. PMID: 39732325. doi:10.1016/j.avsg.2024.12.056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。