最大收缩期加速度测量在复杂血管腔内主动脉修复随访中的诊断价值:一种概念的阐释
本文阐述最大收缩期加速度(ACCmax)这一双功能超声参数在复杂血管腔内主动脉修复(cEVAR)及内脏动脉支架术后随访中的潜在诊断价值。ACCmax在狭窄远端测量,可避免支架内评估和金属伪影干扰,单次内脏动脉测量约需5分钟。作者认为ACCmax可作为cEVAR或内脏动脉支架术后超声随访的有用补充,可能减少辐射暴露、肾毒性和医疗费用。
要点
- ACCmax在动脉血流收缩期上升支最大斜率处测量,以m/s²表示,值越高反映测量点近端动脉灌注越好。
- ACCmax在狭窄远端测量,可避免支架内评估和金属伪影散射对通畅性判断的干扰。
- 作者认为ACCmax可作为cEVAR或内脏动脉支架术后双功能超声随访的有用补充,可能减少辐射暴露、肾毒性和医疗费用。
核心结论
- 作者认为ACCmax测量可作为cEVAR或内脏动脉支架术后双功能超声随访的有用补充,可能减少辐射暴露、肾毒性和医疗费用。
研究设计与样本
- 本文为技术阐述类文章,旨在阐释ACCmax在cEVAR及内脏动脉支架术后随访中的潜在诊断效用。
- cEVAR术后提倡长期监测以发现潜在的支架相关并发症,计算机断层血管造影仍是当前全球临床实践中的标准影像方法。
主要发现
- ACCmax在动脉血流收缩期上升支的最大斜率处测量,手动连接2点创建切线后自动计算最大加速度,以m/s²表示。
- ACCmax值越高反映测量点近端动脉灌注越好。
- 单次内脏动脉ACCmax测量约需5分钟。
- 金属不透射线标记可造成金属伪影和散射,妨碍侧支通畅性的评估。
临床怎么用
- 作者认为ACCmax测量可作为cEVAR或内脏动脉支架术后双功能超声随访的有用补充,可能减少辐射暴露、肾毒性和医疗费用。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: After complex endovascular aortic repair (cEVAR), long-term surveillance is advocated to monitor for potential (stent-related) complications. Although various imaging modalities are used, computed tomography angiography remains the standard in current clinical practice worldwide. However, radiopaque markers can cause metal artifacts and scattering, hampering assessment of patency of side branches. The maximal systolic acceleration (ACCmax) is a relatively new duplex ultrasound (DUS) parameter measured distal to a stenosis, avoiding in-stent assessment and scattering. The aim of this article is to illustrate the potential diagnostic utility of the ACCmax after cEVAR and visceral artery stenting in general. TECHNIQUE: The ACCmax is measured at the maximal slope of the upstroke during the systolic phase in arterial flow. By manually connecting 2 points, a tangent line is created in which the maximal acceleration is automatically calculated and expressed in m/s2. A higher value reflects better arterial perfusion proximal to its measurement point. One measurement of a visceral artery takes about 5 minutes. CONCLUSION: ACCmax measurements can be a useful addition during DUS follow-up after cEVAR or visceral artery stenting, possibly decreasing radiation exposure, nephrotoxicity, and health care costs.Clinical ImpactLong-term surveillance after complex endovascular aortic repair (cEVAR) is necessary to monitor for potential (stent-related) complications. Although CTA is the most common modality for imaging, metal artifacts and scattering can hamper the assessment of stent patency. The maximal systolic acceleration (ACCmax) is a duplex ultrasound based parameter that reflects arterial perfusion proximal to its measurement point. Due to its noninvasive nature, it can be a useful addition during follow-up after cEVAR or visceral artery stenting, possibly decreasing radiation exposure, nephrotoxicity and health care costs as well.
引用
- Willems SA, Brouwers JJWM, Hamming JF, et al. Diagnostic Value of Maximal Systolic Acceleration Measurements in the Follow-up of Complex Endovascular Aortic Repair: Illustration of a Concept. J Endovasc Ther. 2024. PMID: 39513491. doi:10.1177/15266028241296490