使用改良3D打印模型在医师改良腔内移植物中精确开窗治疗累及内脏分支的主动脉夹层
回顾性分析3家医院48例累及内脏分支的胸腹主动脉夹层患者,采用改良3D打印模型辅助医师改良开窗分支腔内修复术(PM-FBEVAR)。技术成功率为患者91.67%、靶血管97.8%,中位随访24个月死亡率为0%。作者认为该技术安全且早期和中期随访结果有前景。
要点
- 改良3D打印模型可辅助PM-FBEVAR术前规划和术中开窗定位。
- 48例患者技术成功率91.67%,靶血管成功率97.8%。
- 围术期主要不良事件包括急性肾损伤3例(6.25%)和短暂性截瘫1例(2.08%)。
核心结论
- 在3D打印辅助下,可实现累及内脏分支的胸腹主动脉夹层快速准确的术中开窗。
- 改良3D打印辅助的PM-FBEVAR在早期和中期随访中似乎是安全且有前景的治疗选择。
研究设计与样本
- 回顾性分析2018年12月至2023年5月3家医院48例(35例男性;平均年龄62.9±11.57岁)累及内脏分支的胸腹主动脉夹层患者的临床数据。
- 所有患者均接受改良3D打印模型辅助的PM-FBEVAR。
- 改良3D打印模型根据医师改良腔内移植物植入后预估的主动脉形态设计,采用聚己内酯复合光敏树脂和立体光刻技术制作,用于术前规划和指导支架移植物修改以辅助开窗定位。
- 随访在所有患者中完成。
主要发现
- 技术成功率为患者44/48(91.67%)、靶血管178/182(97.8%)。
- 平均手术时间371.94±63.47分钟,其中移植物定制平均54.69±9.42分钟,血管内操作平均211.92±55.44分钟。
- 围术期主要不良事件包括急性肾损伤3例(6.25%)和短暂性截瘫1例(2.08%),无永久性神经症状。
- 中位随访24个月(四分位距12-30个月),死亡率为0%。
- 随访期间发现7例内漏:1例Ic型内漏经再干预处理;1例IIIc型内漏自行消失,另1例IIIc型内漏缩小;4例II型内漏均保持稳定。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study aims to summarize the experience and outcomes of using 3D printing technology to assist physician-modified fenestrated-branched endovascular aortic repair (PM-FBEVAR) in the treatment of thoracoabdominal aortic dissection involving visceral branches. MATERIALS AND METHODS: From December 2018 to May 2023, clinical data of 48 consecutive patients (35 males; mean age, 62.9±11.57 years) from 3 hospitals with thoracoabdominal aortic dissection involving visceral branches were retrospectively analyzed. All patients underwent PM-FBEVAR assisted by modified 3D-printed models. The modified 3D-printed models were designed according to estimated aortic morphology after physician-modified endografts were implanted. These models were fabricated using polycaprolactone composite photosensitive resin and stereolithography technology. They were utilized for preoperative planning and guiding the modification of stent grafts to assist in the positioning of the fenestrations. Outcomes including technical success, 30-day mortality, major adverse events (paraplegia, respiratory failure, major stroke, myocardial infarction, acute kidney injury, bowel ischemia, and lower limb ischemia), target vessel-related outcomes (branch occlusion or stenosis, target vessel instability, endoleak), reintervention, and survival were analyzed. Follow-up was completed in all patients. RESULTS: Technical success was achieved in 44 of 48 (91.67%) in patients and 178 of 182 (97.8%) in target vessels. The average operation time was 371.94±63.47 minutes, including a mean of 54.69±9.42 minutes for endograft customization and a mean of 211.92±55.44 minutes for endovascular operation. Perioperative major adverse events include 3 cases (6.25%) of acute renal injury and 1 case (2.08%) of transient paraplegia with no permanent neurological symptoms. The median follow-up was 24 (interquartile range, 12-30) months, and mortality was 0%. Seven endoleaks were detected during follow-up. One type Ic endoleak was managed with a reintervention procedure. One type IIIc endoleak spontaneously disappeared and the other type IIIc endoleak reduced. All 4 type II endoleaks remained stable during follow-up. CONCLUSION: Rapid and accurate intraoperative fenestrations were achieved with the assistance of 3D printing for thoracoabdominal aortic dissection involving visceral branches. The modified 3D printing assisted PM-FBEVAR appears to be a safe and promising treatment option during early and mid-term follow-up.Clinical ImpactThis study highlights the use of modified 3D printed models to enhance the precision of fenestrations in physician-modified endografts for treating thoracoabdominal aortic dissection involving visceral branches. The innovation lies in creating patient-specific 3D models based on pre- and post-implantation anatomy, allowing clinicians to optimize fenestration positioning. This approach has the potential to reduce procedural complexity and improve accuracy, leading to better clinical outcomes. For clinicians, it offers a valuable tool for preoperative planning and intraoperative guidance, potentially streamlining the treatment of complex aortic dissections.
引用
- Jiang Y, Pu H, Lei J, et al. The Use of Modified 3D-Printed Models for Precise Fenestrations in Physician-Modified Endografts to Treat Aortic Dissections Involving Visceral Branches. J Endovasc Ther. 2024. PMID: 39606896. doi:10.1177/15266028241292463
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。