文献速递主动脉疾病

自动化囊腔体积测量在血管腔内主动脉修复术后监测中的获益

The benefit of automated sac volume measurements in postoperative endovascular aortic repair surveillance.
PubMed 文献 · J Vasc Surg · 2024-11-08

这项回顾性研究在两家三级转诊中心纳入89例标准或开窗血管腔内主动脉修复(EVAR)术后患者,利用基于深度学习的自动体积和直径测量比较术前与术后至少2年的囊腔行为。体积评估较直径识别出更多囊腔增长和更少囊腔稳定(P=.003和P<.001),但体积评估的囊腔缩小增加(57% vs 46%)未达统计学显著。作者认为若被更大研究证实,EVAR术后应常规进行囊腔体积评估。

要点

  • 体积评估较直径识别出更多囊腔增长(33% vs 11%,P=.003)和更少囊腔稳定(10% vs 43%,P<.001)。
  • 体积评估的囊腔缩小增加(57% vs 46%)未达统计学显著。
  • 18例直径稳定但体积增长的患者中13例(72%)存在内漏。

核心结论

  • 体积评估的囊腔行为较直径识别出更多囊腔缩小或增长、更少囊腔稳定;若被更大研究证实,EVAR术后应常规进行囊腔体积评估。

研究设计与样本

  • 回顾性研究,纳入两家三级转诊中心接受标准或开窗EVAR治疗的腹主动脉瘤患者,共89例(标准EVAR 46例,开窗EVAR 43例),纳入有术前及术后至少2年计算机断层血管造影的患者。

主要发现

  • 41例(46%)囊腔直径缩小,38例(43%)直径稳定,10例(11%)直径增长;51例(57%)体积缩小,9例(10%)体积稳定,29例(33%)体积增长。
  • 体积评估较直径评估,囊腔增长患者显著更多(P=.003),囊腔稳定患者显著更少(P<.001)。
  • 体积评估的囊腔缩小增加(57% vs 46%)未达统计学显著。
  • 18例(20%)直径稳定且体积增长的患者中,13例(72%)存在内漏(2型9例,1型2例,3型1例,来源不明1例)。

临床怎么用

  • 作者认为若被更大研究证实,EVAR术后应常规进行囊腔体积评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Abdominal aortic aneurysm (AAA) shrinkage is considered a marker for success following endovascular aortic repair (EVAR). Although maximum diameter is widely used to assess sac behavior, research indicates that changes in AAA morphology do not always affect the maximum diameter. The aim of this study was to investigate if automated AAA sac volume measurements after EVAR can add more nuanced information on sac behavior compared with maximum diameter evaluation alone. METHODS: A retrospective review of all patients treated for AAA with a standard or fenestrated EVAR at two tertiary referral centers was performed. Patients with a preoperative and postoperative computed tomography angiography ≥2 years after treatment were included. Data were collected using medical charts, radiological institutional databases, and a deep learning based method called Augmented Reality for Vascular Aneurysm. Volume and diameter assessments were automatically performed on computed tomography angiography using Augmented Reality for Vascular Aneurysm. Preoperative sac volumes and diameters were compared with those obtained at least two years after repair. Information on endoleaks (ELs) was collected. Continuous data were tested using the t test, and categorical data were tested using the χ2 or Fishers test, depending on sample size. RESULTS: A total of 89 patients (standard EVAR n = 46; fenestrated EVAR n = 43) were included in this study. Of the 89 patients, 41 (46%) had sac diameter shrinkage, 38 (43%) had stable sac diameters, and 10 (11%) had diameter sac growth during follow-up. The distribution of sac volume behavior was different among these patients: 51 (57%) had volume shrinkage, 9 (10%) had stable volumes, and 29 (33%) had volume growth. Significantly more patients had sac growth and fewer had sac stability, when assessed with volume compared with diameter (P = .003 and P < .001, respectively). The increase in patients with volume-assessed sac shrinkage (57% vs 46%) was not statistically significant. Of the 18 patients (20%) with stable sac diameters and simultaneous volume growth, 13 (72%) had ELs (type 2 ELs, n = 9; type 1 ELs, n = 2, type 3EL, n = 1, and EL of undefined origin, n = 1). CONCLUSIONS: This study found that volume-assessed sac behavior identifies more sac shrinkage or growth, and less sac stability than diameter does. If confirmed by larger studies, sac volume assessment should be performed routinely after endovascular repair.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Broda M, Rossillon A, Le Houérou T, et al. The benefit of automated sac volume measurements in postoperative endovascular aortic repair surveillance. J Vasc Surg. 2024. PMID: 39522568. doi:10.1016/j.jvs.2024.10.070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。