在慢性肢体威胁性缺血及膝下血管闭塞患者中采用超大球囊血管成形术补偿血管造影的低估
本研究为回顾性单中心研究,纳入84例膝下动脉闭塞病变行球囊血管成形术患者,比较按血管造影1:1选径(造影参考组,43例)与选大0.5 mm球囊(超大组,41例)的疗效。超大组12个月一期通畅率82.9%高于造影参考组62.8%(p=0.039),1年靶病变血运重建率4.9%低于造影参考组20.9%(p=0.029),截肢率两组差异无统计学意义(16.3% vs 9.8%,p=0.382)。
要点
- 超大组12个月一期通畅率82.9%,造影参考组62.8%(p=0.039)。
- 超大组1年靶病变血运重建率4.9%,造影参考组20.9%(p=0.029)。
- 1年截肢率超大组16.3% vs 造影参考组9.8%,差异无统计学意义(p=0.382)。
核心结论
- 在无血管内超声(IVUS)辅助、依据常规血管造影的膝下动脉球囊血管成形术中,将球囊直径选大一号可提高通畅率并降低靶病变血运重建率,而两组截肢率在统计学上相似。
研究设计与样本
- 回顾性单中心研究,共纳入84例膝下动脉闭塞病变行球囊血管成形术患者,分为超大组(41例)与造影参考组(43例)。
- 超大组球囊直径较血管造影1:1选径大0.5 mm;造影参考组按血管造影图像1:1选径。
- 主要终点为目标血管再闭塞,次要终点为大截肢和小截肢。
主要发现
- 12个月一期通畅率造影参考组62.8% vs 超大组82.9%(p=0.039)。
- 1年随访截肢率造影参考组9.8% vs 超大组16.3%(p=0.382)。
- 1年随访靶病变血运重建率超大组4.9% vs 造影参考组20.9%(p=0.029)。
临床怎么用
- 作者认为,在无IVUS条件下行膝下动脉球囊血管成形术时,可依据常规血管造影将球囊直径选大一号,以补偿血管造影的低估。
- 作者指出该策略可为临床医生提供一种实用、经济有效的解决方案,以优化膝下介入的长期结果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Our study aims to determine optimal sizing of below-the-knee (BTK) artery angioplasty without intravascular ultrasound (IVUS), compensating for conventional angiography underestimation by selecting a balloon size one size larger than the 1-to-1 angiographic sizing. MATERIALS AND METHODS: Our study is a retrospective, single-center study. Patients were separated into 2 groups as over and angiographic reference group which the over group is larger balloon diameter selection (0.5-mm larger balloon diameter selection), and angiographic reference group is 1-to-1 balloon diameter selection by angiographic images. Primary end point was the target vessel reocclusion, whereas major and minor amputation was the secondary end point. RESULTS: Eighty-four patients with occluded BTK lesions treated with balloon angioplasty (Opt=43, Over=41). Primary patency was 62.8% at 12 months in angiographic reference group and 82.9% in over group (p=0.039). Amputation rate at 1-year follow-up was 9.8% in angiographic reference group and 16.3% in over group (p=0.382). TLR rate is 4.9% in over group versus 20.9% in angiographic reference group (20.9%) at 1-year follow-up (p=0.029). CONCLUSION: Our study demonstrates that oversizing the balloon diameter by one size larger in BTK artery angioplasty, guided by conventional angiography, results in a higher patency rate and a lower target lesion revascularization (TLR) rate, while amputation rate remains statistically similar between the 2 groups.Clinical ImpactOur study highlights the importance of compensating for conventional angiography's underestimation in BTK artery angioplasty by using a balloon size one size larger than the 1-to-1 angiographic sizing. Our findings demonstrate that oversizing the balloon leads to significantly higher patency rates and lower TLR rates, with no increase in amputation risk. This approach provides a practical, cost-effective solution for clinicians performing angioplasty without IVUS, allowing for better vessel treatment and outcomes in patients with chronic limb-threatening ischemia. Clinicians can implement this strategy to optimize long-term results in BTK interventions.
引用
- Teymen B, Emin Öner M, Erdağ Y, et al. Compensating for Angiographic Underestimation With Oversized Balloon Angioplasty in Patients With Chronic Limb-Threatening Ischemia and Occluded Below-the-Knee Vessels. J Endovasc Ther. 2024. PMID: 39342445. doi:10.1177/15266028241283534
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。