文献速递主动脉疾病外周动脉疾病

腹主动脉瘤东亚患者髂动脉分支装置解剖适用性

Anatomical Suitability of Iliac Branch Devices for East Asian Patients with Abdominal Aortic Aneurysm.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2024-09-20

本研究为单中心回顾性横断面研究,纳入2008至2023年诊断的1144例腹主动脉瘤患者,评估东亚患者髂动脉特征及四种髂动脉分支装置(IBD)按最新说明书(IFU)的解剖适用率。45.5%合并髂总动脉瘤,26.6%需重建髂内动脉;Cook ZBIS、Gore IBE、E-Liac IBD和G-Iliac IBD的解剖适用率分别为18.9%、21.8%、11.9%和22.6%,E-Liac IBD显著低于其他三种装置(p < .001)。53.4%的患者不符合任何IBD的解剖标准。

要点

  • 东亚腹主动脉瘤患者中45.5%合并髂总动脉瘤,26.6%需行髂内动脉重建。
  • 四种IBD解剖适用率18.9%~22.6%,E-Liac IBD显著较低(p < .001)。
  • 53.4%患者不符合任何IBD解剖标准,仅2.7%符合全部四种装置。

核心结论

  • 相当比例东亚腹主动脉瘤患者合并髂总动脉瘤,需大量髂内动脉重建;IBD在东亚人群中解剖适用率低,53.4%患者不符合任何IBD的解剖标准。

研究设计与样本

  • 单中心、回顾性、横断面研究,纳入2008年至2023年诊断的腹主动脉瘤患者,测量髂动脉形态参数,按四种IBD(Cook ZBIS、Gore IBE、E-Liac IBD、G-Iliac IBD)最新说明书评估适用性。

主要发现

  • 共观察1144例腹主动脉瘤,45.5%(n = 521)合并髂总动脉瘤。
  • 共304例患者(26.6%)和371条髂动脉需行髂内动脉重建。
  • Cook ZBIS、Gore IBE、E-Liac IBD和G-Iliac IBD的解剖适用率分别为18.9%、21.8%、11.9%和22.6%。
  • E-Liac IBD解剖适用率显著低于其他三种装置(p < .001)。
  • 主要排除标准:Cook ZBIS为髂总动脉长度< 50 mm(n = 211,56.9%);Gore IBE为髂内动脉直径< 6.5 mm或> 13.5 mm(n = 177,47.7%);E-Liac IBD和G-Iliac IBD为髂总动脉分叉直径< 18 mm(n = 244,65.8%)。

关键数值与推荐

  • Cook ZBIS解剖适用率18.9%,主要排除标准为髂总动脉长度< 50 mm(n = 211,56.9%)。
  • Gore IBE解剖适用率21.8%,主要排除标准为髂内动脉直径< 6.5 mm或> 13.5 mm(n = 177,47.7%)。
  • E-Liac IBD解剖适用率11.9%,主要排除标准为髂总动脉分叉直径< 18 mm(n = 244,65.8%)。
  • G-Iliac IBD解剖适用率22.6%,主要排除标准为髂总动脉分叉直径< 18 mm(n = 244,65.8%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study aimed to identify the iliac artery characteristics of East Asian patients with abdominal aortic aneurysms (AAAs) and to evaluate anatomical suitability rates with current iliac branch devices (IBDs). METHODS: This was a single centre, retrospective, cross sectional study. Patients diagnosed with AAA between 2008 and 2023 were enrolled. The morphological parameters of the iliac arteries were measured, and their eligibility for four IBDs (Cook ZBIS, Gore IBE, E-Liac IBD, and G-Iliac IBD) was evaluated according to the manufacturer's latest instructions for use (IFU). RESULTS: Among 1 144 AAAs observed in the study, 45.5% (n = 521) presented with concurrent common iliac artery aneurysm (CIAA). In total, 304 patients (26.6%) and 371 iliac arteries necessitated internal iliac artery (IIA) reconstruction. The anatomical suitability rates for the Cook ZBIS, Gore IBE, E-Liac IBD, and G-Iliac IBD were 18.9%, 21.8%, 11.9%, and 22.6%, respectively. The E-Liac IBD exhibited a significantly lower anatomical suitability rate compared with the other three devices (p < .001). The primary IBD exclusion criteria were: a common iliac artery (CIA) length of < 50 mm for Cook ZBIS (n = 211, 56.9%); an IIA diameter of < 6.5 mm or > 13.5 mm for Gore IBE (n = 177, 47.7%); and a CIA bifurcation diameter of < 18 mm both for E-Liac IBD and G-Iliac IBD (n = 244, 65.8%). A total of 198 patients (53.4%) failed to meet the anatomical criteria for any device, while 112 (30.2%) qualified for just one device, 26 (7.0%) for two devices, 25 (6.7%) for three devices, and 10 (2.7%) for all four devices. CONCLUSION: A significant proportion of East Asian patients with AAA present with concurrent CIAA, necessitating substantial IIA reconstruction. IBD techniques show low anatomical suitability rates among the East Asian population, with 53.4% of patients failing to meet anatomical criteria for any IBD based on the manufacturer's IFU.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Wu M, Ren L, Wang H, et al. Anatomical Suitability of Iliac Branch Devices for East Asian Patients with Abdominal Aortic Aneurysm. Eur J Vasc Endovasc Surg. 2024. PMID: 39307231. doi:10.1016/j.ejvs.2024.09.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。