文献速递主动脉疾病

密封区失败降低血管内动脉瘤修复的长期耐久性

Sealing Zone Failure Decreases the Long Term Durability of Endovascular Aneurysm Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2024-09-07

该回顾性结构化审查分析了399例连续接受标准分叉型EVAR患者的术前和术后CT,中位随访5.3年。完全和部分密封丧失分别发生于85例(21.3%)和78例(19.5%),13例EVAR后破裂均先有CT示完全或部分密封丧失。结论认为密封丧失常见且与EVAR后破裂相关。

要点

  • 中位随访5.3年,完全密封丧失85例(21.3%),部分密封丧失78例(19.5%)。
  • 13例EVAR后破裂均先有CT示完全(n=7)或部分(n=6)密封丧失。
  • 初始平均密封区长度在推荐范围内但随时间减少,主要因血管扩张。

核心结论

  • EVAR后密封丧失常见且与EVAR后破裂相关。

研究设计与样本

  • 回顾性结构化审查,纳入399例连续接受标准分叉型EVAR患者的术前和术后CT扫描。

主要发现

  • 中位随访5.3年,完全密封丧失85例(21.3%),部分密封丧失78例(19.5%)。
  • 1个月CT时近端密封长度:完全密封丧失组15.5±10.5 mm(95%CI 12.6-18.5 mm),部分密封丧失组14.3±6.9 mm(95%CI 12.2-16.4 mm),密封保持组23.2±7.4 mm(95%CI 22.3-24.0 mm),p<.001。
  • 髂密封长度:完全密封丧失组22.4±12.1 mm(95%CI 18.9-25.8 mm),部分密封丧失组21.8±10.0 mm(95%CI 19.6-24.0 mm),密封保持组34.7±12.4 mm(95%CI 33.8-35.7 mm)。
  • 研究期间发生13例EVAR后破裂,均先有CT示完全(n=7)或部分(n=6)密封丧失。
  • 动脉瘤囊扩张见于完全密封丧失组40%、部分密封丧失组18%、密封保持组6.6%的患者。

临床怎么用

  • 作者认为增加推荐密封区长度并关注监测中的密封区可能减少EVAR后破裂和动脉瘤相关死亡。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular aneurysm repair (EVAR) has a higher long term aneurysm related mortality rate compared with open surgery, mainly due to aneurysm rupture. Loss of stent graft to vessel apposition at the EVAR sealing zones is a potential cause of post-EVAR rupture. This study aimed to investigate sealing zone failure and its relationship with post-EVAR rupture. METHODS: This was a retrospective structured review of pre- and post-operative computed tomography (CT) scans of 399 consecutive patients treated with standard bifurcated EVAR. The primary outcome was total loss of seal at last post-operative CT. Secondary outcomes were partial loss of seal, standard follow up detection, post-EVAR rupture, aneurysm sac development, and endoleaks. RESULTS: During a median follow up of 5.3 years, total and partial loss of seal occurred in 85 (21.3%) and 78 (19.5%) patients, respectively. Initial mean sealing zone lengths were within current recommendations but decreased over time, mainly due to vessel dilatation. Mean proximal sealing length at the one month CT was 15.5 ± 10.5 mm (95% confidence interval [CI] 12.6 - 18.5 mm) in the group with total loss of seal, 14.3 ± 6.9 mm (95% CI 12.2 - 16.4 mm) with partial loss of seal, and 23.2 ± 7.4 mm (95% CI 22.3 - 24.0 mm) with preserved seal through follow up (p < .001). Mean iliac sealing lengths were 22.4 ± 12.1 mm (95% CI 18.9 - 25.8 mm) if total loss and 21.8 ± 10.0 mm (95% CI 19.6 - 24.0 mm) if partial loss of seal vs. 34.7 ± 12.4 mm (95% CI 33.8 - 35.7 mm) if preserved seal. Larger vessel diameters were associated with loss of seal in both the proximal and distal sealing zones. During the study period, 13 post-EVAR ruptures occurred, all preceded by CT findings of total (n = 7) or partial (n = 6) loss of seal. Aneurysm sac expansion was seen in 40% of patients with total loss of seal, 18% with partial loss of seal, and 6.6% with preserved seal. CONCLUSION: Loss of seal after EVAR is frequent and associated with post-EVAR rupture. Increased recommended sealing zones lengths and focus on sealing zones in surveillance may reduce post-EVAR ruptures and aneurysm related death.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Sandström C, Andersson MB, Bogdanovic M, et al. Sealing Zone Failure Decreases the Long Term Durability of Endovascular Aneurysm Repair. Eur J Vasc Endovasc Surg. 2024. PMID: 39251037. doi:10.1016/j.ejvs.2024.09.007