超声参数预测静脉瓣膜相关狭窄血液透析患者主要通畅率的评估
本研究回顾性纳入2017年1月至2021年12月接受超声引导下经皮腔内血管成形术(PTA)的229例静脉瓣膜相关狭窄(VVRS)患者,测量PTA前后超声参数,采用Cox分析寻找与主要通畅率相关的独立因素。结果显示PTA后所有超声参数均改善;PTA前VVRS直径>1.0 mm、年龄≤57岁、BMI>21.57 kg/m2与较好结局相关;PTA后仅VVRS直径>4.0 mm与良好结局相关;PTA后VVRS直径增益>2.4 mm有较好结局趋势。作者认为PTA前后VVRS直径可作为预测主要通畅率和二次通畅率的标志物,直径增益也可能是潜在标志物。
要点
- PTA前VVRS直径>1.0 mm、年龄≤57岁、BMI>21.57 kg/m2与较好结局相关。
- PTA后仅VVRS直径>4.0 mm与良好结局相关。
- PTA后VVRS直径增益>2.4 mm有较好结局趋势。
核心结论
- 作者认为PTA前后VVRS直径可作为预测AVF伴VVRS患者主要通畅率和二次通畅率的标志物,VVRS直径增益也可能是潜在标志物。
- 作者指出使用简单的超声参数标志物可快速识别再狭窄高风险患者,这些患者应更密切随访以及早发现再狭窄,并有助于预防血栓形成。
- 作者指出这些措施有助于为长期透析保留更多有价值的血管,医生应更关注这些高风险患者的透析相关并发症,如血液透析相关低血压。
研究设计与样本
- 回顾性纳入2017年1月至2021年12月期间接受PTA的229例VVRS患者,回顾性收集临床特征。
- PTA前后均测量超声参数,采用单因素和多因素Cox分析确定与主要通畅率相关的独立因素。
主要发现
- PTA后所有测量的超声参数较PTA前改善。
- PTA前VVRS直径>1.0 mm、年龄≤57岁、BMI>21.57 kg/m2与较好结局相关。
- PTA前桡动脉直径、靠近吻合口的近端桡动脉、肱动脉、肱动脉流量、VVRS长度和峰值速度(PV)、VVRS后直径和PV与主要通畅率无关联。
- PTA后仅VVRS直径>4.0 mm的患者有良好结局。
- PTA后VVRS直径增益>2.4 mm的患者有较好结局趋势。
临床怎么用
- 作者认为PTA前后VVRS直径可作为预测主要通畅率和二次通畅率的标志物,VVRS直径增益也可能是潜在标志物。
- 作者建议使用简单超声参数标志物快速识别再狭窄高风险患者,并更密切随访以及早发现再狭窄。
- 作者指出这些措施有助于预防血栓形成并为长期透析保留更多有价值的血管。
- 作者指出医生应更关注高风险患者的透析相关并发症,如血液透析相关低血压。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Ultrasonography is more frequently used in patients with arteriovenous fistula (AVF) stenosis. The aim of this study is to use sonographic parameters for predicting primary patency in hemodialysis patients with venous valve-related stenosis (VVRS) who are treated by ultrasound-guided percutaneous transluminal angioplasty (PTA). METHODS: A total of 229 VVRS patients who underwent PTA between January 2017 and December 2021 were enrolled. Clinical characteristics were retrospectively collected. Sonographic parameters were measured both before and after PTA. Univariate and multivariate Cox analyses were performed to identify independent factors associated with primary patency rate. RESULTS: All measured sonographic parameters improved after PTA compared to before PTA. Before PTA, the diameter of VVRS > 1.0 mm, age ≤ 57 years, and body mass index (BMI) > 21.57 kg/m2 were associated with better outcomes. While the diameter of radial artery, proximal radial artery close to the anastomosis, brachial artery, the flow volume of brachial artery, the length and peak velocity (PV) of the VVRS, and the diameter and PV after the VVRS had no association with the primary patency rate. After PTA, only patients with a diameter of VVRS > 4.0 mm had favorable outcome. In addition, patients with a gain of diameter of VVRS > 2.4 mm after PTA had a trend of better outcomes. CONCLUSIONS: The diameter of VVRS before and after PTA could be served as markers to predict primary patency rate and second patency rate in AVF patients with VVRS. The gain of diameter of VVRS could also be a potential marker.Clinical ImpactUsing simple markers of sonographic parameters, we could quickly identify patients with a higher risk of restenosis. These patients should be followed more closely in case of restenosis at early. It is also beneficial to the prevention of thrombosis. These measures help to preserve more valuable vascular for a long-term dialysis. Additionally, the physician should pay more attention on the dialysis-related complications in these risky patients, such as hemodialysis-related hypotension.
引用
- Xiong Y, Gao X, Cui L, et al. Assessment of Sonographic Parameters for Predicting Primary Patency Rate in Hemodialysis Patients With Venous Valve-Related Stenosis. J Endovasc Ther. 2024. PMID: 39148349. doi:10.1177/15266028241270680
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。