文献速递主动脉疾病内脏/肾动脉与血管畸形

Gore Viabahn球囊扩张式覆膜支架作为复杂主动脉腔内手术桥接支架3年结果:开窗分支表现更优

The Gore Viabahn balloon-expandable stent graft as a bridging stent in complex endovascular aortic procedures at 3 years performs better in fenestrations.
PubMed 文献 · J Vasc Surg · 2024-08-13

本研究前瞻性收集并回顾性分析2018年7月至2022年9月连续接受开窗/分支腔内主动脉修复并以VBX支架作为靶内脏血管桥接支架的63例患者,评估中期疗效。36个月免于TVV不稳定为92.1%±3%,免于TVV相关再干预为90.6%±3.1%,开窗组显著优于分支组(96.8% vs 69.4%,P<.001)。作者认为VBX是可靠的桥接支架,但开窗配置在减少再干预方面更优。

要点

  • 36个月免于靶内脏血管不稳定为92.1%±3%,开窗与分支配置间无差异。
  • 36个月免于TVV相关再干预为90.6%±3.1%,开窗组96.8%显著优于分支组69.4%(P<.001)。
  • 多因素分析显示开窗配置是TVV相关再干预的保护因素(HR 0.079,95%CI 0.016-0.403)。

核心结论

  • VBX支架作为开窗和分支腔内主动脉手术的桥接支架是可靠的。
  • 即刻结果令人满意,但3年内开窗配置在再干预需求方面更优。
  • 手术成功很大程度上依赖于对该支架独特特性的透彻理解。

研究设计与样本

  • 前瞻性收集2018年7月至2022年9月连续接受开窗和分支腔内主动脉修复并以VBX支架作为桥接支架的患者数据,随后进行回顾性分析。
  • 共63例患者,其中动脉粥样硬化性动脉瘤47例(74.6%),夹层后动脉瘤7例(11.1%),吻合口假性动脉瘤或既往EVAR后IA型内漏9例(14.3%)。
  • 主动脉修复共纳入243根内脏血管中的231根(95.1%)。
  • 术中额外需要13枚VBX支架,TVV相关技术成功率为94.4%。
  • 平均随访26.1±16.4个月。

主要发现

  • 36个月估计总生存率为73%±7.5%。
  • 36个月免于IC/IIIC型内漏和TVV一期通畅率分别为90.6%±3.9%和99%±0.7%。
  • 36个月免于TVV不稳定为92.1%±3%,开窗与分支配置间无差异。
  • 36个月免于TVV相关再干预为90.6%±3.1%,开窗组96.8% vs 分支组69.4%(P<.001),显著利于开窗。
  • 多因素分析证实开窗配置是TVV相关再干预的保护因素(HR 0.079;95%CI 0.016-0.403)。

临床怎么用

  • 作者认为VBX支架可作为开窗和分支腔内主动脉手术的可靠桥接支架。
  • 作者指出3年内开窗配置在免于再干预方面优于分支配置。
  • 作者强调手术成功很大程度上依赖于对该支架独特特性的透彻理解。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Complex endovascular procedures are now recognized as the gold standard treatments for extensive aortic diseases. Bridging stents (covered stents used to couple the aortic graft to the visceral vessels) play a pivotal role, yet there is currently no dedicated device available on the market. The aim of the study was to evaluate the midterm performance of the Gore Viabahn balloon-expandable (VBX) stent graft as a bridging stent for target visceral vessels (TVVs). METHODS: Data from all consecutive patients who underwent a fenestrated and branched endovascular aortic repair and received the VBX stent graft as a bridging stent between July 2018 and September 2022 were prospectively collected and subsequently analyzed retrospectively. Primary end points included freedom from TVV instability and freedom from TVV-related reinterventions, both overall and in comparison between branched and fenestrated graft configurations. Secondary end points were overall survival, procedure and TVV-related (in an intent-to-treat basis) technical success, freedom from type IC/IIIC endoleak, and freedom from TVV patency loss. RESULTS: Sixty-three patients were treated with a fenestrated and branched endovascular aortic repair using the VBX stent graft as a bridging stent, of whom 47 (74.6%) presented an atherosclerotic aneurysm, 7 (11.1%) a post-dissecative aneurysm, and 9 (14.3%) an anastomotic pseudoaneursym or a type IA endoleak in a previous endovascular aortic repair. Included in the aortic repair were 231 of 243 (95.1%) total visceral vessels. The intraoperative requirement of 13 additional VBX stent grafts determined a TVV-related technical success of 94.4%. The mean follow-up was 26.1 ± 16.4 months. The estimated overall survival at 36 months was 73% ± 7.5%. The estimated rates at 36 months for freedom from type IC/IIIC endoleaks and TVV primary patency were 90.6% ± 3.9% and 99% ± 0.7%, respectively. The estimated rate at 36 months for freedom from TVV instability was 92.1% ± 3% and did not differ between branched and fenestrated configurations, whereas freedom from TVV-related reinterventions was 90.6% ± 3.1% and significantly in favor of fenestrations (69.4% vs 96.8%, P < .001). Multivariate analyses confirmed fenestrated configuration as a protective factor against TVV-related reinterventions (hazard ratio: 0.079; 95% confidence interval: 0.016-0.403). CONCLUSIONS: The VBX stent graft proves to be a reliable bridging stent for complex aortic procedures involving both fenestrated and branched endografts. Although immediate results are deemed satisfactory, they favor fenestrations regarding the need of reinterventions through 3 years. The success of the procedure heavily relies on a thorough understanding of the unique characteristics of this stent.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Di Domenico R, Esposito D, Speziali S, et al. The Gore Viabahn balloon-expandable stent graft as a bridging stent in complex endovascular aortic procedures at 3 years performs better in fenestrations. J Vasc Surg. 2024. PMID: 39142449. doi:10.1016/j.jvs.2024.08.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。