文献速递主动脉疾病

医师改良反向髂分支装置在紧急分支腔内主动脉修复术中预防脊髓缺血

Physician-Modified Reversed Iliac Branch Device to Prevent Spinal Cord Ischemia in an Urgent Branched Endovascular Aortic Repair.
PubMed 文献 · J Endovasc Ther · 2024-07-26

本文报告一例68岁无症状近肾主动脉瘤快速增大患者,在紧急分支腔内主动脉修复术中,因术中发现粗大腰动脉且脑脊液引流放置失败,采用医师改良反向加载髂分支装置(IBD)连接腰动脉以保留脊髓侧支灌注。术后CT血管造影确认血管通畅,无神经系统症状。作者认为反向加载IBD用于节段动脉保留看似可行且安全。

要点

  • 紧急分支腔内主动脉修复术中,术中发现粗大腰动脉可能对脊髓侧支网络灌注有重要意义。
  • 脑脊液引流放置失败后,采用医师改良反向加载IBD连接腰动脉(8 mm分支至4 mm腰动脉)。
  • 术后CT血管造影确认血管通畅,无神经系统症状发生。

核心结论

  • 作者认为,使用反向加载的髂分支装置保留节段动脉看似可行且安全。

研究设计与样本

  • 本文为技术报告,报告一例68岁男性无症状近肾主动脉瘤快速增大患者的紧急分支腔内主动脉修复术。

主要发现

  • 术中发现粗大腰动脉且脑脊液引流放置失败,手术分期并于5天后使用医师改良髂分支装置完成。
  • 装置被缩短并反向加载以获得朝向头侧的 branch,使用球囊扩张覆膜支架连接反向 branch(8 mm)与腰动脉(4 mm)。
  • 出院前CT血管造影确认血管通畅,未发生神经系统症状。

临床怎么用

  • 作者认为,紧急情况下复杂主动脉重建中,该自适应介入技术也可为保留其他解剖上重要的血管(如副肾动脉)提供策略。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Repair of pararenal aneurysms poses a challenge, especially in an urgent setting. Despite the minimally invasive nature of the fenestrated/branched endovascular aortic repair, the technique may require extensive coverage of the aorta, increasing the risk of spinal cord ischemia. TECHNIQUE: A 68-year-old man was admitted with a rapid enlargement of an asymptomatic juxtarenal aortic aneurysm. A minimally invasive treatment with an off-the-shelf branched endovascular graft was planned. Before completing the aneurysm exclusion, an angiography highlighted a large lumbar artery, potentially significant for the perfusion of the spinal cord collateral network. Owing to this finding and an unsuccessful placement of the cerebrospinal fluid drainage, the procedure was staged and completed 5 days later using a physician-modified iliac branch device (IBD) for the segmental artery. The device was shortened and reversely loaded to obtain a cranially-oriented branch. A balloon-expandable covered stent was used to connect the retrograde branch (8 mm) to the lumbar artery (4 mm). Pre-discharge computed tomography (CT)-angiography confirmed the vessel patency. No neurological symptoms occurred. CONCLUSION: The use of a reversely-loaded IBD for segmental artery preservation appears feasible and safe.Clinical ImpactIntraoperative modification of an iliac branch device during an urgent branched endovascular aortic repair enabled preservation of a potentially critical segmental artery, thus reducing the risk of spinal cord ischemia. This adaptive interventional technique may also offer a strategy for preserving other anatomically significant vessels, such as accessory renal arteries, during complex aortic reconstructions in urgent settings.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Malik K, Kölbel T, Grandi A, et al. Physician-Modified Reversed Iliac Branch Device to Prevent Spinal Cord Ischemia in an Urgent Branched Endovascular Aortic Repair. J Endovasc Ther. 2024. PMID: 39058090. doi:10.1177/15266028241266143

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。