冷冻象鼻手术治疗急性A型主动脉夹层:依据血管外科学会/胸外科医师学会报告标准的远端主动脉重塑分析
回顾性分析41例接受冷冻象鼻手术治疗急性A型主动脉夹层的患者,依据SVS/STS标准评估远端主动脉重塑。Ishimaru 1-4区出现显著正向重塑,但内脏动脉或肾下主动脉无显著变化,总体假腔血栓形成率95.1%。院内死亡7.3%,远期死亡9.7%,中位随访11个月再干预率17.1%。
要点
- 冷冻象鼻术后Ishimaru 1-4区主动脉正向重塑显著,内脏动脉及肾下段无显著变化。
- 总体假腔血栓形成率为95.1%(39例)。
- 主动脉扩张率:1-4区4.9%,5-6区8.3%,7区15%。
核心结论
- 冷冻象鼻手术治疗急性A型主动脉夹层后,依据SVS/STS标准远端胸主动脉出现正向重塑,但对远端主动脉的正面效应限于胸段,未及内脏动脉。
研究设计与样本
- 回顾性分析过去8年因急性A型主动脉夹层接受冷冻象鼻手术患者的临床资料和影像,纳入41例(54.6%),均具备术前及术后至少30天的CT血管造影用于对比。
主要发现
- Ishimaru 1-4区报告显著正向主动脉重塑,但内脏动脉或肾下主动脉无显著正向重塑(P < 0.001)。
- 总体假腔血栓形成率为95.1%(n = 39)。
- 主动脉扩张率:1-4区4.9%,5-6区8.3%,7区15%。
- 院内死亡率为7.3%(n = 3),远期死亡率为9.7%(n = 4)。
- 中位随访11个月(范围1-141),再干预率为17.1%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To investigate impact of frozen elephant trunk (FET) on long-term distal aortic remodeling in acute A aortic dissection (AAD) according to the latest recommended standards from the Society for Vascular Surgery (SVS)/Society of Thoracic Surgeons (STS). METHODS: Clinical data and imaging of patients who underwent FET to treat acute AAD over the last 8 years were retrospectively reviewed. Patients were included if a pre and postoperative computed angio tomographies at least 30 days from surgery was available for comparison. Contrasted postprocessed imaging were analyzed with Aquarius iNtuition (TeraRecon Inc., Foster City, CA, USA) to analyze long-term positive aortic remodeling, false lumen thrombosis, and aortic expansion according to the SVS or STS recommendations. Secondary endpoints were the rate of in-hospital and long-term mortality, spinal cord ischemia (SCI), and aortic-related reinterventions. RESULTS: Out of 75 patients who underwent FET for type A AAD, n = 41 (54.6%) were included. Significant positive aortic remodeling was reported in Ishimaru zone 1-4 but not in visceral or infrarenal aorta (P < 0.001), and the overall rate of false lumen thrombosis was 95.1% (n = 39). Aortic expansion rates were as follows: 4.9% in zones 1-4, 8.3% in zones 5-6, and 15% in zone 7. The rates of in-hospital mortality and long-term mortality were 7.3% (n = 3) and 9.7% (n = 4), respectively. At a median follow-up of 11 months (range 1-141, reintervention rate was 17.1%. CONCLUSIONS: We report positive aortic remodeling of the distal thoracic aorta in patients who underwent FET for acute AAD according to the SVS or STS reporting standards. The positive effect on the distal aorta is limited to the thoracic segments but not in the visceral aorta.
引用
- Borghese O, Sajiram S, Lee M, et al. Frozen Elephant Trunk Procedure for Acute Type a Aortic Dissection: Analysis of Distal Aortic Remodeling According to the Society for Vascular Surgery (SVS)/Society of Thoracic Surgeons (STS) Reporting Standard. Ann Vasc Surg. 2024. PMID: 39009131. doi:10.1016/j.avsg.2024.06.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。