文献速递主动脉疾病

用户友好型形态学分级系统(PATENT)的开发与验证:预测高危非复杂性B型主动脉夹层胸主动脉腔内修复术后主动脉重塑

Development and Validation of a User Friendly Morphology Grading System (PATENT) Predicting Aortic Remodelling After Thoracic Endovascular Aortic Repair in High Risk Uncomplicated Type B Aortic Dissection.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2024-07-05

本研究基于2D计算机断层血管造影图像开发PATENT形态学分级系统,用于预测高危非复杂性B型主动脉夹层患者胸主动脉腔内修复术后不良主动脉重塑。单中心回顾性队列纳入351例患者,99例(28%)发生不良重塑,2年免于不良重塑率为71%(95%CI 65-77%)。系统将患者分为低、中、高危三组,风险评分与不良重塑显著相关(HR 1.21;95%CI 1.14-1.29;p<.001),Harrell C指数0.68(95%CI 0.63-0.75)。

要点

  • PATENT分级系统仅基于2D CTA图像,包含6个独立预测因子,内部验证区分度Harrell C指数0.68。
  • 风险评分每增加1分,不良重塑风险HR 1.21(95%CI 1.14-1.29;p<.001)。
  • 中危组不良重塑HR 2.82(95%CI 1.57-5.01;p=.001),高危组HR 4.39(95%CI 2.58-7.48;p<.001)。

核心结论

  • PATENT分级系统具有良好的区分度和校准度,可能作为临床友好工具帮助TBAD患者TEVAR术后风险分层。

研究设计与样本

  • 单中心回顾性队列研究,连续纳入诊断为高危非复杂性TBAD的患者,共351例。
  • 不良主动脉重塑定义为假腔或主动脉总直径增加,或真腔直径减小。
  • 采用多变量Cox回归模型识别危险因素并建立2年免于不良重塑的预测模型,进一步开发三分类分级系统(低、中、高危组)并进行内部验证。

主要发现

  • 351例患者中99例(28%)发生不良主动脉重塑,中位年龄52岁(四分位距45,62岁),女性56例(16%)。
  • 2年免于不良重塑率为71%(95%CI 65-77%)。
  • 多变量Cox回归分析显示,专利假腔、迷走右锁骨下动脉、锥度比、腹部周径范围、腹腔干或肾动脉受累、四腔道夹层(三个假腔)为独立预测因子,纳入PATENT分级系统。
  • 风险评分与不良重塑显著相关(HR 1.21;95%CI 1.14-1.29;p<.001)。
  • 中危组不良重塑率更高(HR 2.82;95%CI 1.57-5.01;p=.001),高危组更高(HR 4.39;95%CI 2.58-7.48;p<.001)。

关键数值与推荐

  • PATENT分级系统包含六个预测因子:专利假腔、迷走右锁骨下动脉、锥度比、腹部周径范围、腹腔干或肾动脉受累、四腔道夹层(三个假腔)。
  • 风险评分与不良重塑的HR为1.21(95%CI 1.14-1.29;p<.001)。
  • 中危组与不良重塑的HR为2.82(95%CI 1.57-5.01;p=.001),高危组HR为4.39(95%CI 2.58-7.48;p<.001)。
  • Harrell C指数为0.68(95%CI 0.63-0.75)。

临床怎么用

  • 作者认为PATENT分级系统可能作为临床友好工具,帮助TBAD患者TEVAR术后风险分层。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study aimed to create a morphology grading system, solely based on 2D images from computed tomography angiography, to predict negative aortic remodelling (NAR) for patients with high risk uncomplicated type B aortic dissection (TBAD) after thoracic endovascular aortic repair (TEVAR). METHODS: This single centre retrospective cohort study extracted and analysed consecutive patients diagnosed with high risk uncomplicated TBAD. Negative aortic remodelling was defined as an increase in the false lumen or total aortic diameter, or decrease in the true lumen diameter. The multivariable Cox regression model identified risk factors and a prediction model was created for two year freedom from NAR. A three category grading system, in which patients were classified into low, medium, and high risk groups, was further developed and internally validated. RESULTS: Of 351 patients included, 99 (28%) developed NAR. The median age was 52 years (interquartile range 45, 62 years) and 56 (16%) were female. The rate of two year freedom from NAR was 71% (95% CI 65 - 77%). After the multivariable Cox regression analysis, Patent false lumen, Aberrant right subclavian artery, Taper ratio, abdominal circumferential Extent, coeliac artery or reNal artery involved, and four channel dissection (Three false lumens) remained independent predictors and were included in the PATENT grading system. The risk score was statistically significantly associated with NAR (HR 1.21; 95% CI 1.14 - 1.29; p < .001). The medium and high risk groups demonstrated a higher rate of NAR (medium risk, HR 2.82; 95% CI 1.57 - 5.01; p = .001; high risk, HR 4.39; 95% CI 2.58 - 7.48; p < .001). The grading system was characterised by robust discrimination with Harrell's C index of 0.68 (95% CI 0.63 - 0.75). CONCLUSION: The PATENT grading system was characterised by good discrimination and calibration, which may serve as a clinician friendly tool to aid risk stratification for TBAD patients after TEVAR.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Shen Y, Wang J, Zhao J, et al. Development and Validation of a User Friendly Morphology Grading System (PATENT) Predicting Aortic Remodelling After Thoracic Endovascular Aortic Repair in High Risk Uncomplicated Type B Aortic Dissection. Eur J Vasc Endovasc Surg. 2024. PMID: 38972631. doi:10.1016/j.ejvs.2024.07.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。