文献速递主动脉疾病

开放破裂腹主动脉瘤修复中腔内主动脉球囊控制与开放主动脉阻断的比较

Endovascular Aortic Balloon control versus open Aortic cross Clamp in open ruptured abdominal Aortic aneurysm repair.
PubMed 文献 · Ann Vasc Surg · 2024-07-17

本回顾性队列研究纳入2001至2018年单中心174例接受开放手术修复的肾下型破裂腹主动脉瘤成人患者,其中21例采用腔内主动脉球囊控制、137例采用开放主动脉阻断,主要结局为30天死亡率。腔内球囊控制与较低死亡率呈非显著相关(校正OR=0.75,95%CI 0.24至2.38,P=0.63);局部麻醉下置入球囊显示死亡率改善趋势(校正OR=0.34,95%CI 0.06至1.77,P=0.19),全身麻醉下置入球囊与更差死亡率呈非显著相关(校正OR=2.50,95%CI 0.35至9.13,P=0.46)。作者认为在适当选择的患者中可考虑将腔内主动脉球囊控制作为开放主动脉阻断的替代方法。

要点

  • 腔内球囊控制与开放阻断的30天死亡率无显著差异(校正OR=0.75,95%CI 0.24至2.38,P=0.63)。
  • 局部麻醉下置入球囊显示死亡率改善趋势(校正OR=0.34,95%CI 0.06至1.77,P=0.19)。
  • 作者认为在适当选择的患者中可考虑将腔内球囊控制作为开放主动脉阻断的替代方法。

核心结论

  • 在开放手术修复破裂腹主动脉瘤患者中,使用腔内主动脉球囊控制与开放主动脉阻断相比,死亡率无显著差异;作者认为在适当选择的患者中可考虑将其作为开放主动脉阻断的替代方法。

研究设计与样本

  • 2001至2018年在单一三级医疗中心开展的回顾性队列 review,纳入所有接受开放手术修复肾下型破裂腹主动脉瘤的成人患者,共174例,其中21例接受腔内主动脉球囊控制、137例接受开放主动脉阻断;主要结局为30天死亡率;采用两变量多因素 logistic 回归对术前血压和年龄进行校正。

主要发现

  • 腔内主动脉球囊控制与较低死亡率呈非显著相关(校正OR=0.75,95%CI 0.24至2.38,P=0.63)。
  • 局部麻醉下置入球囊显示死亡率改善趋势(校正OR=0.34,95%CI 0.06至1.77,P=0.19)。
  • 全身麻醉下置入球囊与更差死亡率呈非显著相关(校正OR=2.50,95%CI 0.35至9.13,P=0.46)。

临床怎么用

  • 作者认为,在适当选择的接受开放手术修复的破裂腹主动脉瘤患者中,可考虑将腔内主动脉球囊控制作为开放主动脉阻断的替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To determine 30-day mortality of endovascular aortic balloon control compared with open aortic cross clamp in open surgical repair (OSR) of ruptured abdominal aortic aneurysms (rAAAs). METHODS: A retrospective cohort review was performed of all adult patients who underwent OSR of an infrarenal rAAA between 2001 and 2018 at a single tertiary care center. A total of 174 patients were identified, of which 21 patients received endovascular aortic balloon control and 137 patients received an open aortic cross clamp. Primary outcome was 30-day mortality. Two-variable multivariate logistic regression was adjusted for preoperative blood pressure and age. RESULTS: Endovascular aortic balloon control was nonsignificantly associated with lower mortality (adjusted odds ratio [OR] = 0.75 (95% confidence interval [CI] 0.24 to 2.38), P = 0.63), and when placed under local anesthesia showed a trend toward improved mortality (adjusted OR = 0.34 (95%CI 0.06 to 1.77), P = 0.19). Balloon placement under general anesthesia was nonsignificantly associated with worse mortality (adjusted OR = 2.50 (95%CI 0.35 to 9.13), P = 0.46). CONCLUSIONS: There is no significant difference in mortality with the use of endovascular aortic balloon control in rAAA patients undergoing OSR, and it may be considered as an alternative approach to open aortic cross clamp in properly selected patients.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Jones M, Rockley MC, Moore RD, et al. Endovascular Aortic Balloon control versus open Aortic cross Clamp in open ruptured abdominal Aortic aneurysm repair. Ann Vasc Surg. 2024. PMID: 39029893. doi:10.1016/j.avsg.2024.06.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。