本系统综述依据PRISMA指南检索1998年至今多个数据库,纳入11篇原始研究共1069例患者,评估运动诱发电位、体感诱发电位及近红外光谱等神经监测方式在胸主动脉腔内修复和分支/开窗腔内修复术中降低脊髓缺血风险的效果。运动诱发电位联合体感诱发电位最常用,检测脊髓缺血风险的敏感性93%、特异性96%。脊髓缺血发生率为3.8%至17.3%,永久性缺损为2.7%至5.8%,院内死亡率为0.4%至8%。

要点

  • 运动诱发电位联合体感诱发电位检测脊髓缺血风险的敏感性93%、特异性96%。
  • 脊髓缺血发生率为3.8%至17.3%,永久性缺损为2.7%至5.8%,院内死亡率为0.4%至8%。
  • 神经监测变化与实际脊髓缺血结局之间存在不一致,需谨慎解读。

核心结论

  • 运动诱发电位和体感诱发电位神经监测似乎能有效检测胸主动脉腔内修复和分支/开窗腔内修复术中的围术期脊髓缺血风险。
  • 神经监测变化与实际脊髓缺血结局之间存在不一致,提示需谨慎解读。
  • 脊髓缺血发生率仍存在变异,已识别的危险因素可能指导临床决策,尤其在高风险手术中。
  • 未来研究应聚焦前瞻性研究和随机对照试验以验证这些发现并改进脊髓缺血预防策略。

研究设计与样本

  • 遵循PRISMA指南的系统综述,检索PubMed、MEDLINE via Ovid、Embase、Scopus和Cochrane CENTRAL数据库,时间范围为1998年至今。
  • 纳入标准为探讨胸主动脉腔内修复和分支/开窗腔内修复术中神经监测的原始研究文章。
  • 从1450篇文献中纳入11篇,涵盖1069例患者的数据。
  • 使用纽卡斯尔-渥太华量表评估研究质量。

主要发现

  • 神经监测方式包括运动诱发电位、体感诱发电位和近红外光谱。
  • 运动诱发电位联合体感诱发电位最常用,检测脊髓缺血风险的敏感性为93%、特异性为96%。
  • 脊髓缺血发生率为3.8%至17.3%,永久性缺损发生在2.7%至5.8%的病例中。
  • 院内死亡率为0.4%至8%。
  • 已识别的脊髓缺血危险因素包括手术时长和主动脉覆盖范围。

关键数值与推荐

  • 运动诱发电位联合体感诱发电位检测脊髓缺血风险的敏感性93%、特异性96%。
  • 脊髓缺血发生率为3.8%至17.3%,永久性缺损为2.7%至5.8%,院内死亡率为0.4%至8%。

临床怎么用

  • 作者认为,运动诱发电位和体感诱发电位神经监测似乎能有效检测胸主动脉腔内修复和分支/开窗腔内修复术中的围术期脊髓缺血风险。
  • 作者认为,神经监测变化与实际脊髓缺血结局之间的不一致提示需谨慎解读。
  • 作者认为,已识别的危险因素可能指导临床决策,尤其在高风险手术中。

局限性

  • 神经监测变化与实际脊髓缺血结局之间存在不一致,提示需谨慎解读。
  • 脊髓缺血发生率仍存在变异。
  • 未来研究应聚焦前瞻性研究和随机对照试验以验证这些发现并改进脊髓缺血预防策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Spinal cord ischemia (SCI) is a potentially devastating complication of thoracic endovascular aortic repair (TEVAR) and fenestrated-branched endovascular aortic repair (F-BEVAR). The aim of this systematic review was to evaluate the efficacy of neuromonitoring modalities to mitigate the risk of SCI during TEVAR and F-BEVAR procedures. METHODS: Following the PRISMA guidelines, we conducted a detailed literature search of databases including PubMed, MEDLINE via Ovid, Embase, Scopus, and Cochrane CENTRAL, from 1998 to the present. Inclusion criteria were original research articles examining neuromonitoring during TEVAR and F-BEVAR. The primary outcome was the incidence of SCI, while the secondary outcome included early mortality. The quality of studies was assessed using the Newcastle-Ottawa Scale. RESULTS: From 1,450 identified articles, 11 met inclusion criteria, encompassing data from 1,069 patients. Neuromonitoring modalities included motor-evoked potentials (MEPs), somatosensory evoked potentials (SSEPs), and near-infrared spectroscopy. The combination of MEPs and SSEPs was most commonly used, with 93% sensitivity and 96% specificity for detecting SCI risks. SCI incidence ranged from 3.8 to 17.3%, with permanent deficits occurring in 2.7-5.8% of cases. In-hospital mortality ranged from 0.4 to 8%. Risk factors for SCI were identified, including operation duration and extent of aortic coverage. CONCLUSIONS: Neuromonitoring with MEPs and SSEPs appears to be effective in detecting perioperative SCI risk during TEVAR and F-BEVAR. However, discrepancies between neuromonitoring changes and actual SCI outcomes suggest the need for cautious interpretation. While the incidence of SCI remains variable, identified risk factors may guide clinical decisions, particularly in high-risk procedures. Future research should focus on prospective studies and randomized controlled trials to validate these findings and improve SCI prevention strategies in TEVAR and F-BEVAR.