文献速递主动脉疾病内脏/肾动脉与血管畸形

开窗构型对开窗分支腔内主动脉修复术中肾动脉结局的影响

Effect of fenestration configuration on renal artery outcomes during fenestrated-branched endovascular aortic repair.
PubMed 文献 · J Vasc Surg · 2024-06-11

这项回顾性多中心分析纳入796例接受开窗分支腔内主动脉修复术(F/BEVAR)并至少对一条肾动脉使用小开窗的复杂主动脉瘤患者,比较8×6 mm与6×6 mm肾动脉开窗的结局。8×6 mm开窗在30天、1年和5年通畅率更高,而6×6 mm开窗5年免于二次干预率更高、IIIc型内漏更少;开窗间隙≥5 mm对免于靶血管不稳定、免于IIIc型内漏和5年通畅率有负面影响。

要点

  • 8×6 mm肾动脉开窗30天、1年、5年一期通畅率均高于6×6 mm开窗。
  • 6×6 mm开窗5年免于二次干预率更高,主要因IIIc型内漏发生率更低。
  • 肾动脉水平开窗间隙≥5 mm与更差的免于靶血管不稳定、免于IIIc型内漏及5年通畅率相关。

核心结论

  • 肾动脉开窗构型影响结局:8×6 mm小开窗在30天、1年和5年通畅率更好,而6×6 mm小开窗与更低的二次干预率相关,主要因IIIc型内漏发生率更低。
  • 肾动脉水平开窗间隙≥5 mm独立于开窗尺寸或血管直径,显著影响免于靶血管不稳定、免于IIIc型内漏和5年通畅率。

研究设计与样本

  • 回顾性多中心分析,纳入796例接受F/BEVAR并至少对一条肾动脉使用小开窗的复杂主动脉瘤患者,男性占71.7%,平均年龄73.3 ± 8.1岁,平均随访30.0 ± 20.6个月。
  • 共分析1474个肾动脉小开窗,分为1组(8×6 mm,占47.6%)和2组(6×6 mm,占52.4%),在30天、1年和5年节点分析肾动脉一期通畅率、靶血管不稳定(TVI)、免于二次干预(SI)、IIIc型内漏发生率。
  • 开窗间隙(FG)距离作为效应修饰因素分析,并处理了患者层面的聚类。

主要发现

  • 30天节点:1组 vs 2组一期通畅率99.9% vs 98.0%(P < .001),免于TVI 99.6% vs 97.1%(P < .001),免于SI 99.8% vs 98.4%(P = .022),急性肾损伤发生率92.6% vs 92.7%(P = .953)。
  • 1年和5年一期通畅率1组高于2组:1年98.8% vs 96.9%(P = .010),5年97.8% vs 95.7%(P = .021)。
  • 5年免于SI在2组更高:1组93.1% vs 2组96.4%(P = .007);5年IIIc型内漏风险在1组更高:1组4.9% vs 2组2%(P = .005);Ic型内漏两组相近:1组1.3% vs 2组1.6%(P = .689)。
  • 5年肾功能恶化:2组17.8% vs 1组7.6%(P < .001)。
  • FG ≥5 mm对5年累积免于TVI有负面影响:1组FG ≥5 mm为0.714 vs FG <5 mm为0.857(P < .001),2组FG ≥5 mm为0.761 vs FG <5 mm为0.929(P < .001);对5年累积免于IIIc型内漏:1组FG ≥5 mm为0.759 vs FG <5 mm为0.921(P = .034),2组FG ≥5 mm为0.853 vs FG <5 mm为0.979(P < .001);对2组5年累积通畅率:FG ≥5 mm为0.905 vs FG <5 mm为0.938(P = .036),1组FG ≥5 mm为0.963 vs FG <5 mm为0.948(P = .572)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this study was to evaluate the effect of fenestration configuration and fenestration gap on renal artery outcomes during fenestrated-branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective multicenter analysis was performed, including patients with complex aortic aneurysms treated with F/BEVAR that incorporated at least one small fenestration to a renal artery. The renal fenestrations were divided into groups 1 (8 × 6 mm) and 2 (6 × 6 mm). Primary patency, target vessel instability (TVI), freedom from secondary interventions (SIs), occurrence of type IIIc endoleak, all related to the renal arteries, were analyzed at 30-day, 1-year, and 5-year landmarks. The fenestration gap (FG) distance was analyzed as a modifier, and clustering was addressed at the patient level. RESULTS: A total of 796 patients were included in this study, 71.7% male, with a mean age of 73.3 ± 8.1 years. The mean follow-up was 30.0 ± 20.6 months. Of the 1474 small renal fenestrations analyzed, 47.6% were 8 × 6 mm, and 52.4% were 6 × 6 mm. At the 30-day landmark, primary patency (99.9% vs 98.0%; P value < .001 for groups 1 and 2, respectively), freedom from TVI (99.6% vs 97.1%; P value < .001 for groups 1 and 2, respectively), and freedom from SI (99.8% vs 98.4%; P value = .022 for groups 1 and 2, respectively) were higher in 8 × 6 compared with 6 × 6 fenestrations, and the incidence of acute kidney injury was similar across the groups (92.6% vs 92.7%; P value = .953 for groups 1 and 2 respectively). The primary patency at 1 and 5 years was higher in 8 × 6 fenestrations (1-year: 98.8% vs 96.9%; 5-year: 97.8% vs 95.7%, for groups 1 and 2, respectively, P values = .010 and .021 for 1 and 5 year comparisons, respectively). The freedom from SIs was significantly higher among 6 × 6 fenestrations at 5 years (93.1% vs 96.4%, for groups 1 and 2, respectively, P value = .007). The groups were equally as likely to experience a type Ic endoleak (1.3% and 1.6% for 8 × 6 and 6 × 6mm fenestrations, respectively, P = .689). The 6 × 6 fenestrations were associated with higher risk of kidney function deterioration (17.8%) when compared with 8 × 6 fenestrations (7.6%) at 5 years (P < .001). The risk of type IIIc endoleak was significantly higher among 8 × 6 fenestrations at 5 years (4.9% and 2% for 8 × 6 and 6 × 6 mm fenestrations, respectively; P = .005). A FG ≥5 mm negatively impacted the cumulative 5-year freedom from TVI (group 1: FG ≥5 mm = 0.714, FG <5 mm = 0.857; P < .001; group 2: FG ≥5 mm = 0.761, FG <5 mm = 0.929; P < .001) and the cumulative 5-year freedom from type IIIc endoleak (group 1: FG ≥5 mm = 0.759, FG <5 mm = 0.921; P = .034; group 2: FG ≥5 mm = 0.853, FG <5 mm = 0.979; P < .001) in both groups and the cumulative 5-year patency in group 2 (group 1: FG ≥5 mm = 0.963, FG <5 mm = 0.948; P = .572; group 2: FG ≥5 mm = 0.905, FG <5 mm = 0.938; P = .036). CONCLUSIONS: Fenestration configuration for the renal arteries impacts outcomes. The 8 × 6 small fenestrations have better patency at 30 days, 1 year, and 5 years, whereas 6 × 6 small fenestrations are associated with lower rates of SIs, primarily due to a lower incidence of type IIIc endoleaks. FG ≥5 mm at the level of the renal arteries significantly impacts the freedom from TVI, freedom from type IIIc endoleak, and 5-year patency independently of the fenestration size or vessel diameter.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Gomes VC, Parodi FE, Browder SE, et al. Effect of fenestration configuration on renal artery outcomes during fenestrated-branched endovascular aortic repair. J Vasc Surg. 2024. PMID: 38871067. doi:10.1016/j.jvs.2024.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。