文献速递外周动脉疾病

术中传输时间血流作为肝素结合膨体聚四氟乙烯移植物腹股沟下血运重建术后失效的预测因素

Intraoperative Transit-Time Flow as a Predictor of Failure after Infrainguinal Revascularization with Heparin-Bonded Expanded Polytetrafluoroethylene Graft.
PubMed 文献 · Ann Vasc Surg · 2024-05-29

前瞻性注册研究纳入68例使用肝素结合膨体聚四氟乙烯(He-ePTFE)行腹股沟下血运重建的患者,术中测定传输时间血流(TTF)。平均随访18±13个月,7例(10.9%)发生移植物闭塞;TTF≤80 ml/min为移植物闭塞的预测阈值,胫动脉远端吻合与TTF≤80 ml/min为独立预测因素。

要点

  • TTF阈值80 ml/min预测移植物闭塞的敏感度为81.8%、特异度为80.7%
  • TTF≤80 ml/min者6、12、24个月免于移植物闭塞率低于TTF>80 ml/min者
  • 胫动脉远端吻合与TTF≤80 ml/min为移植物闭塞的独立预测因素

核心结论

  • 作者认为TTF可能作为腹股沟下血运重建管理中有价值的工具,TTF≤80 ml/min应被视为移植物闭塞的预测因素,提示考虑追加术中操作以增强动脉血流。
  • 作者建议对需要直接胫动脉血运重建的患者应谨慎,因为其为独立于TTF水平的失效预测因素。
  • 作者指出需要更大样本队列和更长随访时间以证实这些发现。

研究设计与样本

  • 前瞻性注册研究,2020年启动,在3家转诊医院纳入因严重肢体缺血或严重跛行使用He-ePTFE行腹股沟下血运重建的患者,共68例。
  • 全部手术按标准化方案使用HT353 Optima Meter(Transonic Systems Inc.,美国纽约州伊萨卡)测定TTF,研究经机构伦理委员会批准。
  • 采用受试者工作特征曲线分析建立血流阈值预测模型并比较变量。
  • 解剖与临床评估按Rutherford分级、全球肢体解剖分期系统及伤口、缺血、足部感染分类报告。
  • 主要结局为TTF与移植物闭塞的相关性;次要结局包括生存、移植物闭塞的其他预测因素、免于主要不良心血管事件及免于主要截肢。

主要发现

  • 68例中55.8%为Rutherford 5-6级,45.6%为全球肢体解剖分期系统3期,73.5%为伤口、缺血、足部感染3-4级。
  • 远端吻合位于胫动脉水平者占23.5%,移植物平均直径为6.4 mm。
  • 基础与术后TTF分别为27.8±15.6 ml/min与109.0±53.0 ml/min。
  • 平均随访18±13个月后,7例(10.9%)出现移植物闭塞,5例(7.8%)需主要截肢。
  • TTF阈值=80 ml/min的敏感度为81.8%(95%CI 48.2-97.7)、特异度为80.7%(95%CI 68.1-90.0),被选为移植物闭塞的截断值。

关键数值与推荐

  • TTF>80 ml/min组与TTF≤80 ml/min组在6、12、24个月的免于移植物闭塞率分别为95.7%(SE=0.030)vs 65.5%(SE=0.115)、95.7%(SE=0.030)vs 58.9%(SE=0.120)、90.9%(SE=0.054)vs 51.6%(SE=0.126),P=0.0003。
  • 一期通畅率、二期通畅率与保肢率未见统计学差异。
  • 多因素分析中,胫血管远端吻合(比值比8.50)与TTF≤80 ml/min(比值比9.39)为移植物闭塞的独立预测因素。

临床怎么用

  • 作者认为TTF≤80 ml/min应被视为移植物闭塞的预测因素,提示考虑追加术中操作以增强动脉血流。
  • 作者建议对需要直接胫动脉血运重建的患者应谨慎,因为其为独立于TTF水平的失效预测因素。
  • 原文未据此给出其他推荐。

局限性

  • 作者指出需要更大样本队列和更长随访时间以证实这些发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The heparin-bonded expanded polytetrafluoroethylene (He-ePTFE) conduit is an option for patients requiring infrainguinal revascularization (iIR), but the risk of failure may be unpredictable, especially in cases with poor run-off. Intraoperative transit-time flow (TTF) provides an automated and quantitative analysis of flow and may serve as an adjunct evaluation during surgical revascularization. The aim of this study was to assess TTF in patients undergoing iIR with He-PTFE at 3 referral hospitals and to establish a predictive flow threshold for graft occlusion. METHODS: A prospective registry initiated in 2020 enrolled patients undergoing iIR using He-PTFE for critical limb ischemia or severe claudication, and TTF measurement was analyzed. Preoperative assessments of anatomical and clinical characteristics were available for all patients. The HT353 Optima Meter (Transonic Systems Inc., Ithaca, NY, USA) was used in all procedures according to a standardized protocol. The institutional ethics committee approved the study. A predictive model using receiver operating characteristic curve analysis was utilized to establish the threshold of flow, and variables were compared. Anatomical and clinical evaluation were reported according to Rutherford grade, Global Limb Anatomic System and Wound, Ischemia, and foot Infection classification. The main outcome considered was the correlation between TTF and graft occlusion. Secondary outcomes included survival, other predictors of graft occlusion, freedom from major adverse cardiovascular events, and freedom from major amputation. RESULTS: Among 68 patients, 55.8% had Rutherford 5-6, 45.6% had Global Limb Anatomic System 3 and 73.5% had Wound, Ischemia, and foot Infection 3-4. Distal anastomosis was at tibial level in 23.5% and mean diameter of conduit was 6.4 mm. Basal and postoperative TTF were 27.8 ± 15.6 ml/min and 109.0 ± 53.0 ml/min, respectively. After a mean follow-up of 18 ± 13 months, 7 (10.9%) patients presented graft occlusion and 5 (7.8%) required major amputation. TTF threshold = 80 ml/min revealed a sensitivity and specificity of 81.8% (95% confidence interval 48.2-97.7) and 80.7% (95% confidence interval 68.1-90.0) respectively, and it was selected as cut-off for graft occlusion. Freedom from graft occlusion in patients with TTF >80 ml/min vs. TTF ≤80 ml/min at 6, 12, and 24 months was 95.7% (standard error (SE) = 0.030) vs. 65.5% (SE = 0.115), 95.7% (SE = 0.030) vs. 58.9% (SE = 0.120) and 90.9% (SE = 0.054) vs. 51.6% (SE = 0.126), P = 0.0003. No statistical difference in primary patency, secondary patency and limb salvage was observed. At multivariate analysis, distal anastomosis at tibial vessel (odds ratio 8.50) and TTF ≤80 ml/min (odds ratio 9.39) were independent predictors of graft occlusion. CONCLUSIONS: These results suggest that TTF may serve as a valuable tool in the management of iIR. A TTF measurement of ≤80 ml/min should be regarded as a predictor of graft occlusion, prompting consideration of additional intraoperative maneuvers to enhance arterial flow. Caution should be exercised in patients requiring direct tibial artery revascularization, as it represents a predictor of failure independent of TTF levels. Larger cohorts of patients and longer follow-up periods are necessary to confirm these findings.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Mezzetto L, D'Oria M, Mastrorilli D, et al. Intraoperative Transit-Time Flow as a Predictor of Failure after Infrainguinal Revascularization with Heparin-Bonded Expanded Polytetrafluoroethylene Graft. Ann Vasc Surg. 2024. PMID: 38821469. doi:10.1016/j.avsg.2024.04.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。