文献速递主动脉疾病外周动脉疾病

腹主动脉-股动脉旁路术后腹主动脉瘤患者残余髂动脉随逆行血流的变化

Changes in the Remaining Iliac Artery According to Retrograde Flow after Aorto-Femoral Bypass in Abdominal Aortic Aneurysms.
PubMed 文献 · Ann Vasc Surg · 2024-06-01

这项回顾性队列研究纳入2007至2022年在釜山国立大学医院接受腹主动脉瘤手术的221例患者中29例行主-股动脉旁路术者,评估残余髂动脉尺寸变化与股动脉吻合口逆行血流保留状态的相关性。结果显示逆行血流消失者术后髂动脉尺寸较术前显著缩小(18.4±18.9 mm vs 13.2±7.9 mm,P=0.04),逆行血流消失是髂动脉缩小的显著因素(OR 2.5,95%CI 1.9-5.3,P=0.02),但逆行血流消失也增加远期死亡率(HR 8.7,95%CI 1.2-63.9,P=0.03)。

要点

  • 逆行血流消失者术后髂动脉尺寸较术前显著缩小(18.4±18.9 mm vs 13.2±7.9 mm,P=0.04)。
  • 逆行血流保留组残余髂总动脉尺寸显著大于消失组(20.0±28.0 mm vs 14.6±8.5 mm,P=0.02)。
  • 逆行血流消失是髂动脉缩小的显著因素(OR 2.5,95%CI 1.9-5.3,P=0.02),但也增加远期死亡率(HR 8.7,95%CI 1.2-63.9,P=0.03)。

核心结论

  • 腹主动脉瘤开放修复行主-股动脉旁路术时,若股动脉吻合口逆行血流未保留,残余髂动脉尺寸缩小,但逆行血流丧失增加远期死亡率。
  • 行主-股动脉旁路术时,需定期影像随访以适当间隔检查残余髂动脉及逆行血流。

研究设计与样本

  • 回顾性队列研究,纳入2007至2022年釜山国立大学医院221例腹主动脉瘤手术患者中29例行主-股动脉旁路术者。
  • 其中21例行主-双股动脉旁路术,8例行主-髂动脉及股动脉旁路术。
  • 研究残余髂动脉术前至术后的尺寸变化及其是否取决于术后逆行血流状态,并分析影响总体死亡率和缺血并发症的因素。

主要发现

  • 手术至末次随访中位时间2069.5天(约5.7年),患者平均年龄78.1岁,男性占75.9%。
  • 术后股动脉吻合口逆行血流消失者,术后髂动脉尺寸较术前显著缩小(18.4±18.9 mm vs 13.2±7.9 mm,P=0.04)。
  • 逆行血流保留组残余髂总动脉尺寸显著大于血流消失组(20.0±28.0 mm vs 14.6±8.5 mm,P=0.02)。
  • 逆行血流消失是术后髂动脉缩小的显著因素(OR 2.5,95%CI 1.9-5.3,P=0.02)。
  • 逆行血流保留者中3例(18.8%)因髂动脉尺寸增大需干预。

关键数值与推荐

  • Cox比例风险回归分析显示,显著影响总体死亡的因素为慢性阻塞性肺疾病(HR 36.8,95%CI 1.6-870.0,P=0.03)、外周动脉闭塞性疾病(HR 12.7,95%CI 1.4-115.8,P=0.02)及逆行血流消失(HR 8.7,95%CI 1.2-63.9,P=0.03)。

临床怎么用

  • 作者建议行主-股动脉旁路术时,应以适当间隔定期影像随访检查残余髂动脉和逆行血流。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Considering a patient's anatomy and vascular conditions, aorto-femoral bypass is a treatment approach for the open repair of abdominal aortic aneurysms. This study aimed at evaluating changes in the remnant iliac artery and their correlation with the preservation state of retrograde flow from femoral anastomosis. METHODS: Of 221 patients who underwent abdominal aortic aneurysm surgery between 2007 and 2022 in Pusan National University Hospital, 29 patients who underwent aorto-femoral bypass were included in this retrospective cohort study. Of these patients, 21 underwent aortobifemoral bypass and 8 underwent aortoiliac-and-femoral bypass. The change in size of the iliac artery from preoperative to postoperative and whether this difference in size depended on the status of postoperative retrograde flow were investigated. Additionally, factors affecting overall mortality and ischemic complications were identified. RESULTS: The median duration from operation to the last follow-up was 2069.5 days (about 5.7 years). The average age of the patients was 78.1 years, and the proportion of males was 75.9%. In cases of disappearance of postoperative retrograde flow from the femoral anastomosis, the postoperative iliac artery size was significantly reduced compared to its preoperative size (18.4 ± 18.9 mm vs. 13.2 ± 7.9 mm, respectively; P = 0.04). The group with maintained retrograde flow had significantly larger residual common iliac artery size than the group with disappearance of flow. (20.0 ± 28.0 mm vs. 14.6 ± 8.5 mm, respectively; P = 0.02). Disappearance of retrograde flow was a significant factor in the iliac artery size reduction after surgery (odds ratio, 2.5; 95% confidence interval, 1.9-5.3; P = 0.02). Three patients with maintained retrograde flow (18.8%) required intervention owing to an increase in the size of the iliac artery. The factors that significantly influenced overall death as analyzed by Cox proportional hazard regression were chronic obstructive pulmonary disease (hazard ratio, 36.8; 95% confidence interval, 1.6-870.0; P = 0.03), peripheral arterial occlusive disease (hazard ratio, 12.7; 95% confidence interval, 1.4-115.8; P = 0.02), and disappearance of retrograde flow (hazard ratio, 8.7; 95% confidence interval, 1.2-63.9; P = 0.03). CONCLUSIONS: Among the open repair methods for abdominal aortic aneurysms, if retrograde flow was not maintained through femoral anastomosis when aorto-femoral bypass was performed, the size of the remaining iliac artery decreased. However, loss of retrograde flow increased long-term mortality. When aorto-femoral bypass is performed, regular imaging follow-up is necessary at appropriate intervals to check the remnant iliac artery and retrograde flow.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Kang G, Bae M, Chung SW, et al. Changes in the Remaining Iliac Artery According to Retrograde Flow after Aorto-Femoral Bypass in Abdominal Aortic Aneurysms. Ann Vasc Surg. 2024. PMID: 38830448. doi:10.1016/j.avsg.2024.03.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。