使用短尖端远端组件及无交叉概念预防开窗腔内主动脉修复术中靶血管桥接支架受压

Fenestrated Endovascular Repair Using Short Tipped Distal Components with No Cross Concept to Prevent Crushing of Target Vessel Bridging Stents.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2024-06-12

回顾性分析2016年10月至2022年7月单中心70例使用肾动脉开窗的FEVAR患者,比较无交叉短尖端组与标准尖端组各35例。无交叉组技术成功率100% vs 标准组83%(p=.010),术中开窗相关辅助操作占比1.5% vs 8.2%(p=.013),中位随访32个月。

要点

  • 无交叉短尖端组技术成功率100%,标准组83%(p=.010)。
  • 无交叉组开窗相关术中辅助操作占1.5%,标准组占8.2%(p=.013)。
  • 中位随访32个月(四分位距22–62个月),需更大样本和更长随访确认。

核心结论

  • 在FEVAR中采用短尖端远端分叉组件及髂动脉延伸的无交叉概念,显著减少术中开窗相关不良事件并提高技术成功率。
  • 作者指出需更大样本量和更长随访的进一步研究来确认这些发现。

研究设计与样本

  • 回顾性分析2016年10月至2022年7月在一家三级转诊中心接受FEVAR的所有患者。
  • 纳入标准为使用肾动脉开窗,慢性夹层患者被纳入。
  • 共70例患者,无交叉组35例与标准组35例,各组病例均为连续纳入。
  • 所有病例术中均使用锥形束CT,并回顾术后CT血管造影和再干预情况。

主要发现

  • 70例中64例(91%)为近肾动脉瘤,两组人口学、心血管危险因素和动脉瘤特征无差异。
  • 无交叉组技术成功率为100%(全部病例),标准组为83%(29例),p=.010。
  • 无交叉组术中辅助操作占开窗的1.5%,标准组占8.2%,p=.013。
  • 总体中位随访32个月(四分位距22–62个月)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare and evaluate early and midterm outcomes of a novel no cross approach with short tip vs. standard tip introducer systems for all distal components to prevent target vessel bridging stent kink or collapse during fenestrated endovascular aortic repair (FEVAR). METHODS: A retrospective analysis was conducted on all patients who underwent FEVAR at a tertiary referral centre between October 2016 and July 2022. The inclusion criterion was the use of renal artery fenestrations. Patients who had chronic dissections were included. Endpoints were analysed in two groups comprising the no cross group and the standard group, with all cases being consecutive in their respective groups. Cone beam computed tomography was used intra-operatively in all cases, and post-operative computed tomography angiograms and re-interventions were reviewed. Primary endpoints included technical success, intra-operative adjunctive procedures, adverse events related to the fenestration, and re-interventions, while secondary endpoints were secondary interventions and overall mortality rate. RESULTS: Seventy patients (35 in each group) were enrolled in the study, with 64 (91%) having juxtarenal aneurysms. There were no differences in demographics, cardiovascular risk factors, or aneurysm characteristics between the two groups. The no cross group demonstrated a significantly higher technical success rate (100% in all cases) compared with the standard group (29 cases, 83%; p = .010). Additionally, there were statistically significantly fewer intra-operative adjunctive procedures required in the no cross group (1.5% of fenestrations) compared with the standard group (8.2% of fenestrations) (p = .013). The overall median follow up was 32 months (interquartile range 22, 62 months). CONCLUSION: Implementation of a novel no cross concept during FEVAR, using a short dilator introducer tip on the distal bifurcated component and iliac extensions, significantly reduced intra-operative fenestration related adverse events and enhanced technical success. Further studies with larger patient populations and longer follow up are needed to confirm these findings.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Karelis A, Mohammed Y, Oderich GS, et al. Fenestrated Endovascular Repair Using Short Tipped Distal Components with No Cross Concept to Prevent Crushing of Target Vessel Bridging Stents. Eur J Vasc Endovasc Surg. 2024. PMID: 38876370. doi:10.1016/j.ejvs.2024.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。