复杂血管腔内主动脉修复中腹腔干与肠系膜上动脉分支目标血管意外交换
单中心回顾性分析2014至2023年397例接受分支血管腔内主动脉修复的胸腹主动脉瘤患者,其中18例(4.5%)因肠系膜上动脉分支意外开口于腹腔干开口而交换目标血管。36条肠系膜目标血管中34条(94%)成功插管,随访期间交换分支无狭窄或闭塞;30天内3例死亡,中位随访3个月另3例死亡,死亡及2次非计划再干预均与目标血管交换无关。作者认为该技术可行,可在特定病例中考虑。
要点
- 18例(4.5%)患者因肠系膜上动脉分支意外开口于腹腔干开口而交换目标血管。
- 36条肠系膜目标血管中34条(94%)成功插管,包括全部18条肠系膜上动脉和18条中的16条腹腔干。
- 随访期间交换的肠系膜目标血管未发现分支狭窄或闭塞。
核心结论
- 使用成品或定制支架进行分支血管腔内主动脉修复时,交换腹腔干与肠系膜上动脉分支的目标血管可行,目标血管通畅性好且无目标血管相关再干预。
- 作者认为,当经预定分支直接插管被认为更耗时或不可行时,特定病例可考虑此替代技术。
研究设计与样本
- 单中心回顾性分析,纳入2014至2023年接受分支血管腔内主动脉修复的胸腹主动脉瘤患者,使用成品或定制支架,存在腹腔干与肠系膜上动脉分支目标血管意外交换。
- 397例接受分支血管腔内主动脉修复的胸腹主动脉瘤患者中,18例(4.5%)接受了腹腔干与肠系膜上动脉分支目标血管交换。
- 18例中9例(50%)使用T-branch,其余使用定制支架;12例择期、3例有症状、3例破裂。
主要发现
- 18例患者共36条肠系膜目标血管,34条(94%)成功插管,包括全部18条肠系膜上动脉和18条中的16条腹腔干。
- 随访期间交换的肠系膜目标血管未发现分支狭窄或闭塞。
- 30天随访期间3例死亡,中位随访3(四分位距1-15)个月期间另3例死亡。
- 无死亡或2次非计划再干预由肠系膜目标血管交换引起。
- 中位住院时间14(四分位距9-22)天,其中重症监护室中位4(四分位距2-11)天。
临床怎么用
- 作者认为,当经预定分支直接插管被认为更耗时或不可行时,特定病例可考虑交换腹腔干与肠系膜上动脉分支目标血管的替代技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible.Clinical ImpactThis is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.
引用
- Enzmann FK, Grandi A, Panuccio G, et al. Unintended Exchange of Target Vessels for Celiac Trunk and Superior Mesenteric Artery Branches in Complex Endovascular Aortic Repair. J Endovasc Ther. 2024. PMID: 38708984. doi:10.1177/15266028241251985
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。