中弓状韧带致腹腔干动脉压迫对开窗/分支腔内修复术中靶血管通畅性、长期生存及装置完整性的影响
单中心回顾性研究纳入2013至2023年接受开窗/分支腔内主动脉修复并需整合腹腔干动脉的180例复杂主动脉瘤患者,按术前CT血管造影分为中弓状韧带压迫阳性(MAL+,78例)与阴性(MAL-)两组。MAL+组手术复杂度更高、30天死亡率更高(5.1% vs 2.0%),但技术成功率均为100%,长期装置完整性和腹腔干动脉通畅性两组相似。
要点
- MAL+患者更常需裸金属支架辅助(P = .004),估计失血量、手术时间、对比剂用量和透视剂量均更高(P < .001)。
- 30天死亡率为3.3%,MAL+组为5.1%,高于MAL-组的2.0%。
- 中位随访770天时装置完整性均保留,腹腔干动脉事件10例(5.6%),仅2例需再干预。
核心结论
- 中弓状韧带压迫腹腔干动脉是开窗/分支装置植入过程中手术复杂度增加的预测因素,但技术成功率、长期装置完整性和腹腔干动脉通畅性与MAL-解剖患者相似。
研究设计与样本
- 单中心回顾性研究,纳入2013至2023年接受开窗/分支腔内主动脉瘤修复并需整合腹腔干动脉的复杂主动脉瘤患者180例(肾旁128例,胸腹52例)。
- 按术前CT血管造影分为MAL+组(78例,43%)和MAL-组,MAL+组包括A级33例、B级32例、C级13例。
- MAL分级:A级为腹腔干动脉狭窄≤50%且长度≤3 mm;B级为狭窄50%至80%且长度3至8 mm;C级为狭窄>80%且长度>8 mm。
主要发现
- 患者中男性占73%,中位年龄76岁(四分位距69-81岁),动脉瘤中位大小62 mm(四分位距57-69 mm),腹腔干动脉狭窄中位长度7.0 mm(四分位距5.0-10.0 mm)。
- 腹腔干动脉通过开窗整合177例(98%);4例MAL+患者因复杂度增加导致腹腔干动脉桥接支架置入失败,但完成造影显示腹腔干动脉灌注且无内漏,技术成功率为100%。
- MAL+患者更可能需要裸金属支架辅助(P = .004),且估计失血量、中位手术室时间、对比剂用量、透视剂量和时间均更高(P < .001)。
- 30天死亡率为3.3%,MAL+组为5.1%,MAL-组为2.0%。
- 中位随访770天(四分位距198-1525天)时,所有患者装置完整性均保留,腹腔干动脉事件10例(5.6%),包括扭结7例、血栓形成1例和内漏2例,仅2例需再干预;MAL+患者长期生存总体较低。
关键数值与推荐
- 技术成功定义为开窗/分支装置成功植入、腹腔干动脉灌注且无内漏,本研究中为100%。
- MAL分级标准:A级狭窄≤50%且长度≤3 mm,B级狭窄50%至80%且长度3至8 mm,C级狭窄>80%且长度>8 mm。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the impact of celiac artery (CA) compression by median arcuate ligament (MAL) on technical metrics and long-term CA patency in patients with complex aortic aneurysms undergoing fenestrated/branched endograft repairs (F/B-EVARs). METHODS: Single-center, retrospective review of patients undergoing fenestrated/branched endovascular aortic aneurysm repairs and requiring incorporation of the CA between 2013 and 2023. Patients were divided into two groups-those with (MAL+) and without (MAL-) CA compression-based on preoperative computed tomography angiography findings. MAL was classified in three grades (A, B, and C) based on the degree and length of stenosis. Patients with MAL grade A had ≤50% CA stenosis measuring ≤3 mm in length. Those with grade B had 50% to 80% CA stenosis measuring 3 to 8 mm long, whereas those with grade C had >80% stenosis measuring >8 mm in length. End points included device integrity, CA patency and technical success-defined as successful implantation of the fenestrated/branched device with perfusion of CA and no endoleak. RESULTS: One hundred and eighty patients with complex aortic aneurysms (pararenal, 128; thoracoabdominal, 52) required incorporation of the CA during fenestrated/branched endovascular aortic aneurysm repair. Majority (73%) were male, with a median age of 76 years (interquartile range [IQR], 69-81 years) and aneurysm size of 62 mm (IQR, 57-69 mm). Seventy-eight patients (43%) had MAL+ anatomy, including 33 patients with MAL grade A, 32 with grade B, and 13 with grade C compression. The median length of CA stenosis was 7.0 mm (IQR, 5.0-10.0 mm). CA was incorporated using fenestrations in 177 (98%) patients. Increased complexity led to failure in CA bridging stent placement in four MAL+ patients, but completion angiography showed CA perfusion and no endoleak, accounting for a technical success of 100%. MAL+ patients were more likely to require bare metal stenting in addition to covered stents (P = .004). Estimated blood loss, median operating room time, contrast volume, fluoroscopy dose and time were higher (P < .001) in MAL+ group. Thirty-day mortality was 3.3%, higher (5.1%) in MAL+ patients compared with MAL- patients (2.0 %). At a median follow-up of 770 days (IQR, 198-1525 days), endograft integrity was observed in all patients and CA events-kinking (n = 7), thrombosis (n = 1) and endoleak (n = 2) -occurred in 10 patients (5.6%). However, only two patients required reinterventions. MAL+ patients had overall lower long-term survival. CONCLUSIONS: CA compression by MAL is a predictor of increased procedural complexity during fenestrated/branched device implantation. However, technical success, long-term device integrity and CA patency are similar to that of patients with MAL- anatomy.
引用
- Manunga J, Cravero E, Goldman J, et al. Examining the impact of median arcuate ligament-induced celiac artery compression on target vessel patency, long-term survival and device integrity in fenestrated and branched endovascular repairs. J Vasc Surg. 2024. PMID: 38723909. doi:10.1016/j.jvs.2024.04.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。