新型双向双袖套内分支用于复杂血管腔内主动脉修复的多中心经验
本研究回顾性分析了三个三级主动脉中心2022年3月至2023年6月连续13例接受开窗分支血管腔内主动脉修复(F/BEVAR)并使用至少一个双向双袖套内分支的患者,共置入15个内分支(30个袖套),其中23个袖套被使用。中位随访7个月,靶血管置入全部成功,无靶血管不稳定或再干预,两例死亡与内分支无关。
要点
- 双向双袖套内分支用于肾动脉和肠系膜动脉的纳入,技术成功率高。
- 中位随访7个月无靶血管不稳定或再干预,无分支相关并发症。
- 两例死亡与双向分支无关;长期结果仍缺乏。
核心结论
- 双向双袖套内分支的初步经验结果 promising,技术成功率高且短期无分支相关并发症,但长期结果仍缺乏。
研究设计与样本
- 回顾性综述,纳入三个三级主动脉中心2022年3月至2023年6月连续接受F/BEVAR并整合至少一个双向双袖套内分支的患者,共13例(10例男性;中位年龄72[68,77]岁)。
主要发现
- 共使用15个双向双袖套内分支(30个袖套),其中23个袖套被使用,7个袖套有意用血管塞封堵。
- 所有双向分支的靶血管置入均成功;1例技术失败与经单向尾侧内分支尝试插管左肾动脉未成功有关。
- 中位随访7个月,无靶血管不稳定或再干预,2例患者死于与双向分支无关的原因。
关键数值与推荐
- 双向双袖套内分支的适应证包括:颅侧血管朝向或双肾动脉各4例,共同腹腔肠系膜干3例,早期肾动脉分叉、肾动脉起源于假腔需灵活路径插管、以及 surplus configuration 各1例。
局限性
- 长期结果仍缺乏。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.
引用
- Berczeli M, Kölbel T, Tsilimparis N, et al. Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair. Eur J Vasc Endovasc Surg. 2024. PMID: 38705454. doi:10.1016/j.ejvs.2024.04.040
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。