标准降主动脉腔内修复术的国家诊断参考水平及优化策略
这项回顾性横断面研究通过西班牙11个自治区17个中心的266例胸主动脉腔内修复术(TEVAR)数据,确定了移动X线系统和复合手术室的全国诊断参考水平(DRL)。结果显示复合手术室的KAP和CAK诊断参考水平分别为移动系统的2.48倍和3.98倍。
要点
- TEVAR全国DRL:移动X线系统KAP 113.81 Gy·cm2,复合手术室282.59 Gy·cm2。
- TEVAR全国DRL:移动系统CAK 228.38 mGy,复合手术室910.64 mGy。
- 复合手术室较移动C臂的DRL倍数:KAP为2.48倍,CAK为3.98倍。
核心结论
- 基于了解标准腔内手术辐射剂量的需求,本TEVAR研究显示复合手术室较移动C臂系统的KAP诊断参考水平增加2.48倍,CAK诊断参考水平增加3.98倍。
- 这些结果将有助于优化TEVAR手术中降低辐射剂量的策略。
研究设计与样本
- 分析来自17个西班牙中心的266例TEVAR手术,其中53.0%在复合手术室中完成。
- 全国诊断参考水平定义为各参与中心中位值的第三四分位数。
主要发现
- 提出的全国诊断参考水平:移动X线系统KAP为113.81 Gy·cm2,复合手术室为282.59 Gy·cm2。
- 提出的全国诊断参考水平:患者入口参考点累积空气比释动能(CAK)移动系统为228.38 mGy,复合手术室为910.64 mGy。
- 复合手术室较移动C臂系统的诊断参考水平倍数:KAP增加2.48倍,CAK增加3.98倍。
关键数值与推荐
- 移动X线系统KAP诊断参考水平:113.81 Gy·cm2。
- 复合手术室KAP诊断参考水平:282.59 Gy·cm2。
- 移动X线系统CAK诊断参考水平:228.38 mGy。
- 复合手术室CAK诊断参考水平:910.64 mGy。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The International Commission on Radiological Protection has highlighted the large number of medical specialties that use fluoroscopy outside diagnostic imaging departments without radiation protection programmes for patients and staff. Vascular surgery is one of these specialties. Thoracic endovascular aortic repair (TEVAR) is a complicated procedure requiring radiation protection guidance and optimisation. The recent EU Basic Safety Standards Directive requires the use and periodic updating of diagnostic reference levels (DRLs) for interventional procedures. The aim of this study was to determine doses for patients undergoing TEVAR with mobile Xray systems and hybrid rooms (fixed Xray systems) to obtain national DRLs and to suggest optimisation actions. METHODS: This was a retrospective cross sectional study. The Spanish Chapter of Endovascular Surgery conducted a national survey in 11 autonomous communities representing around 77.6% of the Spanish population (47.33 million inhabitants). A total of 266 TEVAR procedures from 17 Spanish centres were analysed, of which 53.0% were performed in hybrid operating rooms. National DRLs were obtained and defined as the third quartile of the median values from the different participating centres. RESULTS: The proposed national DRLs are: for kerma area product (KAP), 113.81 Gy·cm2 for mobile Xray systems and 282.59 Gy·cm2 for hybrid rooms; and for cumulative air kerma (CAK) at the patient entry reference point, 228.38 mGy for mobile systems and 910.64 mGy for hybrid rooms. CONCLUSION: Based on the requirement to know radiation doses for standard endovascular procedures, this study of TEVARs demonstrated that there is an increased factor of 2.48 in DRLs for KAP when the procedure is performed in a hybrid room compared with mobile C-arm systems, and an increased factor of 3.98 in DRLs for CAK when the procedure is performed with hybrid equipment. These results will help to optimise strategies to reduce radiation doses during TEVAR procedures.