预先行假腔栓塞预防开窗分支腔内修复术后夹层后胸腹主动脉瘤持续性II型内漏
描述一种在开窗/分支腔内修复(F/B-EVAR)治疗夹层后胸腹主动脉瘤(PD-TAAA)时促进假腔血栓化的技术。2019至2023年应用于11例,中位弹簧圈数73枚(四分位距12)。8例(72%)有1年影像随访,其中7例完全假腔血栓化。作者认为该技术可行、安全、有效。
要点
- 经最远端破口将5/6Fr鞘从真腔送入假腔并置于胸主动脉假腔最头侧。
- 释放主动脉内移植物隔绝内脏旁/远端破口并桥接支架后,经鞘行选择性假腔造影。
- 用M-reye可推送弹簧圈自上而下栓塞假腔,2019至2023年11例中位73枚(IQR=12)。
核心结论
- 在F/B-EVAR治疗的PD-TAAA中行假腔弹簧圈栓塞促进完全假腔血栓化是可行、安全且有效的。
研究设计与样本
- 技术描述类研究,2019至2023年该技术应用于11例PD-TAAA患者。
主要发现
- 11例应用该技术,中位弹簧圈数为73枚(四分位距12)。
- 8例(72%)患者有1年影像随访,其中7例表现为完全假腔血栓化。
关键数值与推荐
- 5/6Fr-90 cm长鞘经肾下主动脉或髂动脉最远端破口从真腔进入假腔,并置于胸主动脉假腔最头侧。
- 释放主动脉内移植物于真腔以隔绝所有内脏旁/远端破口,并行目标内脏血管桥接支架。
- 经5/6Fr鞘行选择性假腔造影以识别所有段动脉起源。
- 使用M-reye可推送弹簧圈自上而下栓塞假腔,实现假腔填塞。
临床怎么用
- 作者认为该技术可常规推荐用于促进PD-TAAA行F/B-EVAR后的假腔血栓化和主动脉重塑,从而减少随访期间再干预的发生率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose was to describe a technique to promote false lumen (FL) thrombosis in post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs) managed by fenestrated/branched endografting (F/B-EVAR). TECHNIQUE: A 5/6Fr-90 cm length sheath is advanced from the true lumen (TL) to FL through the most distal entry tear of the infrarenal aorta or iliac arteries. It is parked in the most cranial portion of the FL in the thoracic aorta. Aortic endografts are deployed in the TL excluding all the para-visceral/distal entry tears and target visceral vessels bridging stenting is performed. A selective FL angiography is performed through the 5/6Fr sheath to detect the origin of all segmentary arteries. Embolization of FL is performed from above to below by M-reye pushable coils, obtaining the packaging of FL. After completion angiography, the 5/6Fr sheath is retrieved in external iliac artery and molding ballooning of the distal segment of the aortic/iliac endograft is performed. Between 2019 and 2023, this technique was applied in 11cases with a median number of 73 (interquartile range [IQR=12) coils. Out of 8 (72%) patients with available radiological follow-up at 1 year, 7 exhibited complete FL thrombosis. CONCLUSIONS: The FL coiling in PD-TAAAs managed by F/B-EVAR is feasible, safe, and effective to promote the complete FL thrombosis.Clinical ImpactPreemptive false lumen embolization is a feasible, safe, and effective technique for preventing persistent type II endoleaks after fenestrated-branched endovascular repair of post-dissection thoracoabdominal aortic aneurysms. This technique may be routinely recommended to promote FL thrombosis and aortic remodeling after FB-EVAR in PD-TAAAs, thereby reducing the incidence of reinterventions during follow-up.
引用
- Gallitto E, Faggioli G, Poliseno C, et al. Pre-emptive False Lumen Embolization to Prevent Persistent Type II Endoleak in Fenestrated-Branched Endovascular Repair of Post-Dissection Thoracoabdominal Aortic Aneurysms. J Endovasc Ther. 2024. PMID: 38659327. doi:10.1177/15266028241246656