文献速递主动脉疾病内脏/肾动脉与血管畸形

烟囱与开窗腔内动脉瘤修复术后血流动力学特性的评估

Evaluation of Hemodynamic Properties After Chimney and Fenestrated Endovascular Aneurysm Repair.
PubMed 文献 · Ann Vasc Surg · 2024-03-16

本研究利用3例患者(每种术式各3例)的术前术后CT血管造影重建个体化模型,通过计算流体动力学模拟比较开窗(FEVAR)与烟囱(ChEVAR)腔内主动脉修复术后血流动力学特性。结果显示两种术式均使血流动力学趋于正常,ChEVAR在内脏动脉入口处再循环区域较少,而FEVAR在内脏支架内反流强度较低。

要点

  • 两种术式术后均可见血流动力学整体改善,壁面剪切应力紊乱改善,振荡剪切指数下降。
  • ChEVAR内脏动脉血流更趋于流线型,但与FEVAR在肾动脉和肠系膜上动脉开窗处再循环区域的差异未达统计学显著(P=0.06)。
  • FEVAR在内脏支架内显示较低强度的血流反流。

核心结论

  • ChEVAR与FEVAR似乎均能使血流动力学向正常值改善,减少主体移植物和主动脉分支内的再循环区域。
  • 内脏动脉血流比较显示,ChEVAR在平行移植物入口处再循环区域 tended to 较少,而FEVAR在内脏支架内反流强度较低。

研究设计与样本

  • 本研究为计算流体动力学模拟研究,利用术前和术后CT血管造影重建基于患者的模型。
  • 每种术式各分析3例患者的数据。
  • 几何重建后,采用计算流体动力学模拟提取近壁和血管内血流动力学指标。

主要发现

  • 两种术式术后均检测到血流动力学整体改善。
  • 术前在瘤囊多个区域记录到紊乱的促血栓形成壁面剪切应力轮廓。
  • 局部归一化螺旋度结果显示术后螺旋结构组织更好,两种术式均减少血栓形成。
  • 术后时间平均壁面剪切应力增加、振荡剪切指数降低,提示血流非紊乱。
  • 相对停留时间局部降低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Malatos S, Fazzini L, Raptis A, et al. Evaluation of Hemodynamic Properties After Chimney and Fenestrated Endovascular Aneurysm Repair. Ann Vasc Surg. 2024. PMID: 38492732. doi:10.1016/j.avsg.2023.12.084

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。