术中超声稀释法血流测量可预测桡动脉-头静脉动静脉内瘘的成熟
该回顾性队列研究纳入55例患者,比较术中超声稀释法(TTFM)测定的血流量与术后6周动静脉内瘘成熟情况。桡动脉-头静脉内瘘术中平均血流量为156 mL/min,以160 mL/min为界值,等于或低于该值的患者术后6周内瘘成熟失败风险是高于该值者的3.03倍(P < .001),推荐将160 mL/min作为预测桡动脉-头静脉内瘘成熟失败的最佳界值。
要点
- 桡动脉-头静脉内瘘术中平均血流量为156 mL/min。
- 术中血流量≤160 mL/min者术后6周内瘘成熟失败风险为>160 mL/min者的3.03倍(P < .001)。
- 推荐以160 mL/min作为预测桡动脉-头静脉内瘘术后6周成熟失败的界值。
核心结论
- 术中TTFM测定的桡动脉-头静脉内瘘血流量可充分预测术后6周内瘘成熟失败。
- 推荐将160 mL/min作为桡动脉-头静脉内瘘预测术后6周成熟失败的界值,以获得最大敏感度和特异度。
研究设计与样本
- 回顾性队列研究,纳入55例患者,比较术中TTFM测定的血流量与术后6周动静脉内瘘成熟情况。
- 因桡动脉-头静脉内瘘患病率及非成熟风险显著更高,本研究以该类型内瘘为主要研究对象。
- 采用受试者工作特征曲线确定桡动脉-头静脉内瘘术中高血流量与低血流量的推荐界值。
主要发现
- 桡动脉-头静脉内瘘术中平均血流量为156 mL/min。
- 术中血流量等于或低于界值160 mL/min的患者,术后6周内瘘成熟失败风险为术中血流量高于160 mL/min者的3.03倍(P < .001)。
关键数值与推荐
- 桡动脉-头静脉内瘘术中血流量界值为160 mL/min,用于区分高血流量与低血流量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The arteriovenous fistula (AVF) is the first choice for gaining vascular access for hemodialysis. However, 20% to 50% of AVFs fail within 4 months after creation. Although demographic risk factors have been described, there is little evidence on the intraoperative predictors of AVF maturation failure. The aim of this study was to assess the predictive value of intraoperative transit time flow measurements (TTFMs) on AVF maturation failure. METHODS: In this retrospective cohort study, intraoperative blood flow, measured using TTFM, was compared with AVF maturation after 6 weeks in 55 patients. Owing to its significantly higher prevalence and risk of nonmaturation, the radiocephalic AVF (RCAVF) was the main focus of this study. A recommended cutoff point for high vs low intraoperative blood flow was determined for RCAVFs, using a receiver operating characteristic curve. RESULTS: The average intraoperative blood flow in RCAVFs was 156 mL/min. Patients with an intraoperative blood flow equal or lower than the determined cutoff point of 160 mL/min, showed a 3.03 times increased risk of AVF maturation failure after 6 weeks, compared with patients with a higher intraoperative blood flow (P < .001). CONCLUSIONS: The intraoperative blood flow in RCAVFs measured by TTFM provides an adequate means of predicting AVF nonmaturation 6 weeks after surgery. For RCAVFs, a cutoff point for intraoperative blood flow of 160 mL/min is recommended for maximum sensitivity and specificity to predict AVF maturation failure after 6 weeks.
引用
- de Winter EP, Wilschut D, Plasmans K, et al. Intraoperative transit time flow measurement predicts maturation of radiocephalic arteriovenous fistulas. J Vasc Surg. 2024. PMID: 38432488. doi:10.1016/j.jvs.2024.02.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。