文献速递慢性静脉疾病

小腿肌肉泵功能降低不能用手握力测量解释

Reduced calf muscle pump function is not explained by handgrip strength measurements.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2024-03-07

研究纳入115例转诊行无创静脉检查的患者,采用静脉空气体积描记法测量小腿肌肉泵功能(射血分数<45%定义为降低),并用握力计测量最大握力。左右手与对应小腿配对分析显示握力与小腿肌肉泵功能无显著相关(右侧Spearman相关系数0.16,左侧0.10),握力不能作为小腿肌肉泵功能降低的替代指标。

要点

  • 小腿肌肉泵功能降低在右腿53例(46%)、左腿67例(58%)中观察到。
  • 握力与小腿肌肉泵功能之间无显著相关,右侧Spearman相关系数0.16、左侧0.10。
  • 握力测量不能作为小腿肌肉泵功能降低的替代指标。

核心结论

  • 握力与小腿肌肉泵功能之间无显著相关,握力测量不是小腿肌肉泵功能降低的可接受替代指标,提示两者病理生理机制不同。

研究设计与样本

  • 研究纳入转诊至Gonda血管实验室行无创静脉检查并签署知情同意的患者,共115例,平均年龄59.2±17.4岁,女性67例,平均体重指数30.83±6.46。

主要发现

  • 小腿肌肉泵功能降低定义为射血分数<45%,右腿53例(46%)、左腿67例(58%)存在降低。
  • 小腿肌肉泵功能双侧降低45例(39%)、单侧降低30例(26%)。
  • 握力双侧降低74例(64.3%)、单侧降低23例(20%)、正常18例(15.7%)。
  • 每侧手与对应小腿配对比较,握力与小腿肌肉泵功能均无显著相关,Spearman秩相关系数右侧为0.16、左侧为0.10。

关键数值与推荐

  • 小腿肌肉泵功能降低的截断值为射血分数<45%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Reduced calf muscle pump function (CPF) is an independent risk factor for venous thromboembolism and mortality. We aimed to evaluate the relationship between handgrip strength (HGS) and CPF. METHODS: Patients referred to the Gonda Vascular Laboratory for noninvasive venous studies were identified and consented. Patients underwent standard venous air plethysmography protocol. CPF (ejection fraction) was measured in each lower extremity of ambulatory patients by comparing refill volume after ankle flexes and passive refill volumes. The cutoff for reduced CPF (rCPF) was defined as an ejection fraction of <45%. Maximum HGS bilaterally was obtained (three trials per hand) using a dynamometer. HGS and CPF were compared (right hand to calf, left hand to calf) and the correlation between the measures was evaluated. RESULTS: 115 patients (mean age, 59.2 ± 17.4 years; 67 females, mean body mass index, 30.83 ± 6.46) were consented and assessed for HGS and CPF. rCPF was observed in 53 right legs (46%) and 67 left legs (58%). CPF was reduced bilaterally in 45 (39%) and unilaterally in 30 (26%) patients. HGS was reduced bilaterally in 74 (64.3%), unilaterally in 23 (20%), and normal in 18 (15.7%) patients. Comparing each hand/calf pair, no significant correlations were seen between HGS and CPF. The Spearman's rank correlation coefficients test yielded values of 0.16 for the right side and 0.10 for the left side. CONCLUSIONS: There is no significant correlation between HGS and CPF, demonstrating that HGS measurements are not an acceptable surrogate for rCPF, indicating different pathophysiological mechanisms for each process.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Ghorbanzadeh A, Abud A, Liedl D, et al. Reduced calf muscle pump function is not explained by handgrip strength measurements. J Vasc Surg Venous Lymphat Disord. 2024. PMID: 38460817. doi:10.1016/j.jvsv.2024.101869

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。