本研究回顾性分析了2009年2月至2018年10月期间300例接受胸主动脉腔内修复术(TEVAR)并术中监测运动诱发电位(MEP)的患者,以MEP波幅下降≥50%为阈值界定脊髓缺血(SCI)风险组。结果显示仅1.0%出现即刻截瘫,无迟发性截瘫;多因素分析显示高脂血症、支架移植物覆盖长度≥8个椎体及血液透析是SCI的独立危险因素。作者认为MEP可能是预测TEVAR术中SCI的有用监测工具。

要点

  • 300例TEVAR术中MEP监测,以波幅下降<50%为阈值,17例归为SCI风险组,仅1.0%出现即刻截瘫。
  • 多因素分析显示血液透析(OR 27.78)、高脂血症(OR 3.55)、支架覆盖≥8椎体(OR 1.35)为SCI危险因素。
  • MEP波幅下降时术中平均动脉压约升高20 mmHg,常规控制约80 mmHg。

核心结论

  • MEP可能是预测TEVAR术中脊髓缺血的有用监测工具。
  • 高脂血症、支架移植物覆盖长度≥8个椎体及血液透析是TEVAR术中SCI的关键危险因素。

研究设计与样本

  • 回顾性分析2009年2月至2018年10月期间330例TEVAR中的300例接受术中MEP监测的患者。
  • 以MEP波幅下降至术前值的50%以下为阈值提取SCI风险组,并分析TEVAR中SCI的危险因素。

主要发现

  • MEP监测共提取283例非SCI风险患者和17例SCI风险患者。
  • 仅1.0%出现即刻截瘫,无迟发性截瘫发生。
  • 双变量分析显示慢性肾脏病、血液透析、Adamkiewicz动脉闭塞及支架移植物覆盖长度≥8个椎体差异有统计学意义。
  • 逻辑回归分析显示高脂血症(OR 3.55,95%CI 1.08-11.67;p=.037)、支架移植物覆盖长度≥8个椎体(OR 1.35,95%CI 1.02-1.78;p=.034)及血液透析(OR 27.78,95%CI 6.02-128.22;p<.001)是TEVAR中SCI最有影响的危险因素。

关键数值与推荐

  • MEP波幅下降至术前值的50%以下时,术中平均动脉压通过去甲肾上腺素升高约20 mmHg。
  • 术中平均动脉压通常控制于约80 mmHg。
  • 通过增加心输出量、纠正贫血及尽快结束手术等其他措施提高MEP波幅。

临床怎么用

  • 作者认为MEP可能是预测TEVAR术中SCI的有用监测工具。
  • 作者指出高脂血症、支架移植物覆盖长度≥8个椎体及血液透析是TEVAR术中SCI的关键危险因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study investigated the usefulness of motor evoked potentials (MEPs) for intra-operative monitoring to detect the risk of spinal cord ischaemia (SCI) during thoracic endovascular aortic repair (TEVAR). Risk factors for SCI in TEVAR were also analysed. METHODS: Among 330 TEVARs performed from February 2009 to October 2018, 300 patients underwent intra-operative MEP monitoring. SCI risk groups were extracted based on MEP amplitude changes using a cutoff value of 50%. When the amplitude decreased to < 50% of the pre-operative value, intra-operative mean arterial pressure (MAP) was increased by about 20 mmHg using noradrenaline, whereas MAP was usually controlled to about 80 mmHg during surgery. Other efforts were also made to increase MEP amplitude by increasing cardiac output, correcting anaemia, and finishing the surgery promptly. Based on MEP amplitude data, SCI risk groups were extracted and risk factors for SCI in TEVAR were analysed. RESULTS: A total of 283 non-SCI risk patients and 17 SCI risk patients by MEP monitoring were extracted; only 1.0% developed immediate paraplegia and none developed delayed paraplegia. Bivariable analysis showed significant differences in chronic kidney disease, haemodialysis, artery of Adamkiewicz closure, and stent graft (SG) covered length ≥ 8 vertebral bodies. Logistic regression analysis showed hyperlipidaemia (odds ratio [OR] 3.55, 95% confidence interval [CI] 1.08 - 11.67; p = .037), SG covered length ≥ 8 vertebral bodies (OR 1.35, 95% CI 1.02 - 1.78; p = .034), and haemodialysis (OR 27.78, 95% CI 6.02 - 128.22; p < .001) were the most influential risk factors for SCI in TEVAR. CONCLUSION: MEPs might be a useful monitoring tool to predict SCI in TEVAR. In addition, hyperlipidaemia, SG covered length ≥ 8 vertebral bodies, and haemodialysis represent key risk factors for SCI during TEVAR.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。