如何规避远端桡动脉入路的潜在陷阱:来自尸体与CTA分析的启示
研究通过26例福尔马林固定上肢和168例连续患者的上肢CTA,评估远端桡动脉(dRA)解剖基础、理想穿刺点及dTRA潜在陷阱。结果显示穿刺点1和3成功率较高(191/302,63.2%),并提出DISFAVOR理论总结8类潜在陷阱。
要点
- 穿刺点1和3可能更适于dTRA,可能成功率63.2%(191/302)。
- DISFAVOR理论归纳8类可能中断穿刺或导致手术失败的陷阱。
- 尸体解剖dRA平均直径2.53(SD=0.73)mm,CTA为2.63(SD=0.69)mm。
核心结论
- 穿刺点1和3更适于dTRA,作者提出DISFAVOR理论总结dTRA使用中8类潜在陷阱。
研究设计与样本
- 研究26例福尔马林固定上肢和168例连续患者的上肢CTA,采用尸体解剖和dRA三维重建评估dTRA路径,并在患者和尸体中测量穿刺点、dRA直径及dRA与拇短伸肌腱角度。
主要发现
- 尸体解剖较dRA三维重建提供更多信息,但术前评估诊断准确性更好(p=0.024)。
- 穿刺点1和3成功率较高,可能成功率63.2%(191/302)。
- 尸体解剖和CTA测得dRA平均直径分别为2.53(SD=0.73)mm和2.63(SD=0.69)mm。
- 基于CTA,dRA外层至皮肤的最小距离为5.71(SD=2.0)mm。
- 尸体解剖和CTA测得dRA与拇短伸肌腱(TEPB)夹角分别为58.0°(SD=21.5°)和51.8°(SD=16.6°)。
关键数值与推荐
- DISFAVOR理论包括8类潜在陷阱:闭塞、狭窄、迂曲、动静脉瘘、血管瘤、桡动脉(RA)分支变异、桡静脉和头静脉。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To verify the anatomical basis, ideal puncture sites, and potential pitfalls of the distal radial artery (dRA) in the anatomical snuffbox region for distal radial access (dTRA). MATERIALS AND METHODS: Overall, 26 formalin-fixed upper limbs and computed tomography angiography (CTA) of the upper limbs of 168 consecutive patients were studied. Cadaveric dissection and dRA 3D reconstruction were used to evaluate the dRA route for dTRA. The puncture sites, dRA diameter, and angle of the dRA and tendons of the extensor pollicis brevis were also measured in the patients and cadavers. RESULTS: The cadaver dissection provided more insights than did the dRA 3D reconstruction. However, preoperative evaluation had better diagnostic accuracy (p=0.024). Puncture sites 1 and 3 had a high success rate (63.2% possible success rate, 191/302). The DISFAVOR theory was put forward, in which 8 types of potential pitfalls that may interrupt puncture procedure or lead to a surgical failure were observed, including occlusion, stenosis, tortuosity, arteriovenous fistula, angioma, different radial artery (RA) ramifications, radial veins, and cephalic veins. The mean diameter of dRA based on cadaver dissection and CTA was 2.53 (SD=0.73) and 2.63 (SD=0.69) mm, respectively. Furthermore, the minimum distance from the outer layer of dRA to the skin was 5.71 (SD=2.0) mm based on CTA. The angle between the dRA and tendons of extensor pollicis brevis (TEPB) based on cadaver dissection and CTA was 58.0° (SD=21.5°) and 51.8° (SD=16.6°), respectively. CONCLUSIONS: Puncture sites 1 and 3 were more suitable for the dTRA, and we put forward the DISFAVOR theory to summarize the 8 types of potential pitfalls during the use of dTRA.
引用
- Wang P, Shan Y, Xiao B, et al. How to Omit the Potential Pitfalls in Distal Radial Access: Lessons From Cadaveric and CTA Analysis. J Endovasc Ther. 2024. PMID: 38326308. doi:10.1177/15266028241229062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。