开窗与烟囱/ snorkel 技术血管内修复近肾腹主动脉瘤的系统综述与Meta分析
该系统综述与Meta分析纳入9项回顾性队列研究,比较开窗血管内动脉瘤修复(FEVAR)与烟囱移植物血管内动脉瘤修复(ChEVAR)治疗近肾腹主动脉瘤的效果。FEVAR组726例,ChEVAR组518例。FEVAR在技术成功(OR 3.24,95%CI 1.24-8.42)和避免1型内漏(OR 5.76,95%CI 1.94-17.08)方面有显著优势,但脊髓缺血风险更高(OR 10.21,95%CI 1.21-86.11),事件数很少。结论认为两种技术安全性均良好,证据不支持任一技术优越。
要点
- FEVAR技术成功优势显著(OR 3.24,95%CI 1.24-8.42)。
- FEVAR避免1型内漏优势显著(OR 5.76,95%CI 1.94-17.08)。
- FEVAR脊髓缺血风险更高(OR 10.21,95%CI 1.21-86.11),事件数很少。
核心结论
- 两种血管内技术安全性均良好,证据不支持FEVAR或ChEVAR任一技术对近肾腹主动脉瘤的优越性。
研究设计与样本
- 系统综述与Meta分析,检索MEDLINE、EMBASE和Cochrane对照试验注册库自1990年1月1日起的随机和非随机研究,比较FEVAR与ChEVAR用于近肾腹主动脉瘤修复。
- 纳入9项回顾性队列研究进行Meta分析,FEVAR组726例,ChEVAR组518例;男性分别为598例(86.8%)和332例(81.6%)。
- ChEVAR组平均直径更大(59 mm vs 52.5 mm)。
主要发现
- 术后30天死亡率:FEVAR组3.38%(8/237) vs ChEVAR组3.52%(8/227),无显著差异。
- 急性肾损伤:FEVAR组16.76%(31/185) vs ChEVAR组17.31%(18/104),无显著差异。
- 主要不良心脏事件:FEVAR组7.30%(46/630) vs ChEVAR组6.60%(22/333),无显著差异。
- 技术成功:FEVAR较ChEVAR有显著优势(OR 3.24,95%CI 1.24-8.42)。
- 避免1型内漏:FEVAR较ChEVAR有显著优势(OR 5.76,95%CI 1.94-17.08);脊髓缺血:FEVAR风险更高(OR 10.21,95%CI 1.21-86.11),事件数很少。
关键数值与推荐
- FEVAR与ChEVAR术后30天死亡率分别为3.38%(8/237)和3.52%(8/227)。
- 急性肾损伤发生率分别为16.76%(31/185)和17.31%(18/104)。
- 主要不良心脏事件发生率分别为7.30%(46/630)和6.60%(22/333)。
- 技术成功OR 3.24(95%CI 1.24-8.42),避免1型内漏OR 5.76(95%CI 1.94-17.08),脊髓缺血OR 10.21(95%CI 1.21-86.11)。
- 大多数结局的证据质量评为「中等」。
临床怎么用
- 数据提示两种技术在适应证明确时均安全适用。
- 由于各研究组基线风险存在差异,无法确立任一干预的优越性。
局限性
- 纳入的9项研究均为回顾性队列研究。
- 各研究组参与者基线风险存在差异,导致无法确立任一干预的优越性。
- 脊髓缺血结局的事件数很少。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Comparative effectiveness of fenestrated endovascular aneurysm repair (FEVAR) and chimney graft endovascular aneurysm repair (ChEVAR) for juxtarenal aortic aneurysms (JAAs) remains unclear. Our objective was to identify and analyze the current body of evidence comparing the effectiveness of both techniques for JAA. METHODS: We performed a systematic review and meta-analysis comparing the effectiveness of FEVAR and ChEVAR for JAA repair. We searched MEDLINE, EMBASE, and Cochrane Register for Controlled Trials from January 1, 1990, for randomized and non-randomized studies assessing outcomes of FEVAR and ChEVAR for JAA repair. Screening, data extraction, risk of bias assessment, and GRADE (Grading of Recommendations, Assessments, Development, and Evaluations) certainty of evidence were performed in duplicate. Data were pooled statistically where possible. RESULTS: Nine retrospective cohort studies comparing the use of FEVAR and ChEVAR for juxtarenal aneurysm were included for meta-analysis. The FEVAR and ChEVAR arms of the meta-analysis consisted of 726 participants and 518 participants, respectively. There were 598 (86.8%) and 332 (81.6%) men in each arm. The mean diameter was larger in the ChEVAR arm (59 mm vs 52.5 mm). Both techniques had similar rates of postoperative 30-day mortality, 3.38% (8/237) versus 3.52% (8/227), acute kidney injury, 16.76% (31/185) versus 17.31% (18/104), and major adverse cardiac events, 7.30% (46/630) versus 6.60% (22/333). The meta-analysis supported the use of FEVAR for most outcomes, with significant advantage for technical success (odds ratio [OR]: 3.24, 95% CI: 1.24-8.42) and avoidance of type 1 endoleak (OR: 5.76, 95% CI: 1.94-17.08), but a disadvantage for spinal cord ischemia (OR: 10.21, 95% CI: 1.21-86.11), which had a very low number of events. The quality of evidence was "moderate" for most outcomes. CONCLUSION: Both endovascular techniques had good safety profiles. The evidence does not support superiority of either FEVAR or ChEVAR for JAA. CLINICAL IMPACT: While lack of equipoise has hampered the design of randomised trials of open versus endovascular repair of juxtarenal aortic aneurysms, concern about the durability of endovascular repair highlights the need for stronger evidence of the comparative efficacy of endovascular techniques. This review performed meta-analysis and evidence appraisal of recent data from large observational studies comparing fenestrated and chimney techniques, using a comprehensive outcome set. Superiority of either intervention could not be established due to differences in participants' baseline risk in each study arm. However, data suggests that both techniques are safe and suitable for use when indicated.
引用
- Baldeh T, Reilly T, Mansoor T, et al. Systematic Review and Meta-analysis of Fenestrated and Chimney/Snorkel Techniques for Endovascular Repair of Juxtarenal Aortic Aneurysms. J Endovasc Ther. 2024. PMID: 38388373. doi:10.1177/15266028241231171
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。