文献速递主动脉疾病

韩国腹主动脉瘤患者中超出与符合使用说明的血管内修复长期结局

Long-Term Outcomes of Endovascular Repair Within and Outside the Instructions for Use in Korean Patients With Abdominal Aortic Aneurysm.
PubMed 文献 · J Endovasc Ther · 2024-02-27

该研究纳入1997至2021年韩国2个医疗中心546例因肾下腹主动脉瘤行血管内动脉瘤修复(EVAR)的患者,比较符合与超出使用说明(IFU)的长期结局。超出IFU者287例(52.6%),其移植物相关不良事件(GRAE)发生率高于符合IFU者(HR 1.879;95%CI 1.045-2.386)。颈角>60°是GRAE、1或3型内漏及再干预的独立危险因素。

要点

  • 超出IFU行EVAR者GRAE发生率高于符合IFU者(HR 1.879;95%CI 1.045-2.386)。
  • 颈角>60°是GRAE的独立危险因素(校正HR 2.229;95%CI 1.418-3.503)。
  • 颈角>60°亦与1或3型内漏及再干预独立相关。

核心结论

  • 超出IFU行EVAR与GRAE增加相关,主要归因于内漏和动脉瘤相关死亡;严重颈角是GRAE、1或3型内漏和再干预的独立危险因素。

研究设计与样本

  • 研究纳入1997至2021年韩国2个医疗中心因肾下腹主动脉瘤行EVAR的546例患者,比较符合与超出IFU的长期结局。

主要发现

  • 超出IFU者287例(52.6%),其中颈角>60°最常见(n=146,50.9%)。
  • 超出IFU者GRAE发生率高于符合IFU者(HR 1.879;95%CI 1.045-2.386)。
  • 颈角>60°是GRAE的危险因素(校正HR 2.229;95%CI 1.418-3.503)。
  • 颈角>60°是1或3型内漏的危险因素(校正HR 2.640;95%CI 1.343-5.189)。
  • 颈角>60°是再干预的危险因素(校正HR 1.891;95%CI 1.055-3.388)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular aneurysm repair (EVAR) has been used worldwide to treat abdominal aortic aneurysms (AAAs). Outcomes after EVAR within and outside the instruction for use (IFU) remain controversial. We analyzed long-term outcomes of EVAR within-the-IFU compared with that outside-the-IFU and baseline clinical/anatomical characteristics that influence outcomes of EVAR. METHODS: The study included 546 patients who underwent EVAR for infrarenal AAA from 1997 to 2021 at 2 Korean medical centers. The primary endpoint was graft-related adverse events (GRAEs), including type 1 or 3 endoleak, reintervention (included open conversion), aneurysm sac enlargement, aneurysm-related mortality (ARM), rupture, stent-graft migration, and stent thrombotic occlusion. RESULTS: The patients who underwent EVAR outside the IFU were 287 (52.6%). A neck angle of >60° was most common outside the IFU criteria (n=146, 50.9%). This study revealed that patients outside the IFU had a higher rate of GRAEs compared with patients within the IFU (hazard ratio [HR]: 1.879; 95% confidence interval [CI]: 1.045-2.386). A neck angle of >60° was a significant risk factor for GRAEs (adjusted HR: 2.229; 95% CI: 1.418-3.503), type 1 or 3 endoleak (adjusted HR: 2.640; 95% CI: 1.343-5.189), and reintervention (adjusted HR: 1.891; 95% CI: 1.055-3.388). CONCLUSIONS: Our study revealed EVAR with outside the IFU was associated with increased GRAEs, mainly attributed to endoleak and ARM, compared with EVAR with within the IFU. In addition, severe neck angulation was an independent risk factor for GRAEs, type 1 or 3 endoleak, and reintervention.Clinical ImpactOur study revealed endovascular aneurysm repair (EVAR) with outside-the-instruction for use (IFU) was associated with increased graft-related adverse events (GRAEs) compared with EVAR with within-the-IFU. In the low-risk population, the incidence of GRAEs and Aneurysm related mortality were higher in the outside-the-IFU group rather than within-the-IFU group. In addition, severe neck angulation was an independent risk factor for GRAEs, type 1 or 3 endoleak and reintervention.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Lee J, Oh PC, Jang AY, et al. Long-Term Outcomes of Endovascular Repair Within and Outside the Instructions for Use in Korean Patients With Abdominal Aortic Aneurysm. J Endovasc Ther. 2024. PMID: 38414229. doi:10.1177/15266028241232915

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。