基于计算机断层扫描的全自动深度神经网络用于主动脉最大直径和体积测量的多中心临床评估
本研究在两家医院216例患者的350份主动脉CTA扫描上,评估全自动深度学习方法ARVA分割主动脉并测量各节段最大直径和体积的能力,与6位专家(金标准)和13位临床医生的手动测量比较。ARVA与金标准的直径中位绝对差为1.6毫米,在临床可接受范围内的比例为85.5%,与临床医生手动测量结果相当。
要点
- ARVA与专家金标准直径中位绝对差1.6毫米,与临床医生手动测量结果相当。
- ARVA测量在临床可接受范围内的比例为85.5%,临床医生手动测量为86.0%。
- ARVA在主动脉主干体积相似性误差为0.93至0.95,髂动脉为0.88。
核心结论
- 本研究证明全自动人工智能解决方案可靠,能快速分割主动脉并分析各节段的直径和体积。
研究设计与样本
- 临床验证数据集来自两家医院216例患者的术前和术后主动脉CTA扫描,共350份扫描。
- ARVA将主动脉分割为七个基于形态的节段,测量各节段最大外壁至外壁横径并计算体积,与6位专家(金标准)和13位临床医生的测量比较。
主要发现
- 金标准与ARVA的直径中位绝对差为1.6毫米(95%CI 1.5-1.7),金标准与临床医生的直径中位绝对差为1.6毫米(95%CI 1.6-1.7)。
- ARVA测量在临床可接受范围内的比例为85.5%(95%CI 83.5-86.3),临床医生为86.0%(95%CI 83.9-86.0)。
- 主要主动脉干体积相似性误差为0.93至0.95,髂动脉达到0.88。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aims to evaluate a fully automatic deep learning-based method (augmented radiology for vascular aneurysm [ARVA]) for aortic segmentation and simultaneous diameter and volume measurements. METHODS: A clinical validation dataset was constructed from preoperative and postoperative aortic computed tomography angiography (CTA) scans for assessing these functions. The dataset totaled 350 computed tomography angiography scans from 216 patients treated at two different hospitals. ARVA's ability to segment the aorta into seven morphologically based aortic segments and measure maximum outer-to-outer wall transverse diameters and compute volumes for each was compared with the measurements of six experts (ground truth) and thirteen clinicians. RESULTS: Ground truth (experts') measurements of diameters and volumes were manually performed for all aortic segments. The median absolute diameter difference between ground truth and ARVA was 1.6 mm (95% confidence interval [CI], 1.5-1.7; and 1.6 mm [95% CI, 1.6-1.7]) between ground truth and clinicians. ARVA produced measurements within the clinical acceptable range with a proportion of 85.5% (95% CI, 83.5-86.3) compared with the clinicians' 86.0% (95% CI, 83.9-86.0). The median volume similarity error ranged from 0.93 to 0.95 in the main trunk and achieved 0.88 in the iliac arteries. CONCLUSIONS: This study demonstrates the reliability of a fully automated artificial intelligence-driven solution capable of quick aortic segmentation and analysis of both diameter and volume for each segment.
引用
- Postiglione TJ, Guillo E, Heraud A, et al. Multicentric clinical evaluation of a computed tomography-based fully automated deep neural network for aortic maximum diameter and volumetric measurements. J Vasc Surg. 2024. PMID: 38325564. doi:10.1016/j.jvs.2024.01.214