文献速递主动脉疾病

主动脉腔内修复术后超声造影:在早期和长期随访中补充并可能替代CT

Contrast-Enhanced Ultrasound after Endovascular Aortic Repair: Supplement and Potential Substitute for CT in Early- and Long-Term Follow-Up.
PubMed 文献 · Ann Vasc Surg · 2024-01-30

该单中心回顾性分析纳入101例EVAR术后常规随访中接受CEUS的患者,比较CEUS与CTA/MRA对内漏的检出率和分型。首次CEUS检出内漏的敏感度91.2%、特异度100%、阳性预测值100%、阴性预测值84.6%,未发现影响正确分型的协变量。作者认为CEUS是CTA的有效补充方法,建议早期联合CEUS随访。

要点

  • 首次CEUS检出内漏敏感度91.2%、特异度100%、阳性预测值100%、阴性预测值84.6%。
  • 44例(43.5%)检出内漏,以II型为主(占纳入患者的37.6%)。
  • 未发现年龄、BMI、最大主动脉瘤直径、内漏方向或距表面距离影响CEUS或CT的正确分型。

核心结论

  • CEUS应被视为EVAR术后终身随访中CTA的有效补充方法。
  • II型内漏似乎是常见的早期并发症,有时可自行消退,且可能被CTA漏检,作者建议在术后早期评估中采用包含CEUS的联合随访方案。

研究设计与样本

  • 单中心回顾性分析,纳入在本中心EVAR术后常规随访中接受CEUS的患者,共101例。
  • 比较可获得的术后CTA/磁共振血管造影与随访CEUS对内漏的检出率和分型。
  • 以EVAR术前最后一次CTA为基线,分析年龄、体重指数、最大主动脉瘤直径、内漏方向及距表面距离等潜在协变量对检出率和分型的影响。

主要发现

  • 101例患者中,首次CEUS或CTA共检出44例内漏(占43.5%),以II型为主(占纳入患者的37.6%)。
  • 首次CEUS检出内漏的敏感度为91.2%,特异度为100%,阳性预测值为100%,阴性预测值为84.6%。
  • 未发现任何协变量对CEUS或CT的正确分型有影响。

临床怎么用

  • 作者认为CEUS应被视为EVAR术后终身随访中CTA的有效补充方法。
  • 作者建议在术后早期评估中采用包含CEUS的联合随访方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Endoleaks are the most common complication after endovascular aneurysm repair (EVAR). Computed tomography angiography (CTA) is presently the golden standard for lifelong surveillance after EVAR. Several studies and meta-analyses have shown contrast-enhanced ultrasound (CEUS) to be a good alternative. The main goal of our study was to further validate the inclusion of CEUS in follow-up examination protocols for the systematic surveillance after EVAR. METHODS: A retrospective analysis of patients who had received CEUS as part of their routine surveillance after EVAR at our center was conducted. Detection rate and classification of endoleak types were compared between available postinterventional CTA/magnetic resonance angiography and follow-up CEUS examinations. Last preinterventional CTAs before EVAR served as baselines with focus on potential cofactors such as age, body mass index, maximum aortic aneurysm diameters, endoleak orientation, and distance-to-surface influencing detection rates and classification. RESULTS: In total, 101 patients were included in the analysis. Forty-four endoleaks (43.5% of cases) were detected by either initial CEUS or CTA, mostly type II (37.6% of the included patients). Initial CEUS showed an endoleak sensitivity of 91.2%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 84.6%. No covariate with an influence on the correct classification could be identified either for CEUS or CT. CONCLUSIONS: CEUS should be considered a valid complementary method to CTA in the lifelong surveillance after EVAR. As type II endoleaks seem to be a common early-term, sometimes spontaneously resolving complication that can potentially be missed by CTA, we suggest combined follow-up protocols including CEUS in the early on postinterventional assessment.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Morell-Hofert D, Gruber L, Gruber H, et al. Contrast-Enhanced Ultrasound after Endovascular Aortic Repair: Supplement and Potential Substitute for CT in Early- and Long-Term Follow-Up. Ann Vasc Surg. 2024. PMID: 38301847. doi:10.1016/j.avsg.2023.11.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。