文献速递主动脉疾病

半分支:治疗复杂主动脉病变的新工具

The Semibranch: A New Tool for Complex Aortic Pathologies.
PubMed 文献 · J Endovasc Ther · 2023-12-22

本文介绍半分支作为治疗胸腹主动脉、近肾及肾旁主动脉病变的新工具,并在2例患者中演示该技术。两例患者分别因腹主动脉瘤腔内修复术后Ia型内漏和近肾动脉瘤接受治疗,共4个半分支均成功封堵动脉瘤。作者认为半分支可扩大腔内治疗的患者范围,尤其适用于主动脉直径小或靶血管间距短且分支角度相同的患者。

要点

  • 半分支是一种治疗胸腹主动脉及近肾、肾旁主动脉病变的新工具。
  • 在2例患者中,共4个半分支均成功封堵动脉瘤,置入、插管、桥接支架输送及密封均顺利。
  • 作者认为主动脉直径小或靶血管间距短且分支角度相同的患者可能从半分支设计中获益。

核心结论

  • 半分支是腔内介入医生工具库中的又一工具,可扩大可治疗的患者范围。
  • 作者认为主动脉直径小或靶血管间距短且分支角度相同的患者可能从半分支设计中获益。

研究设计与样本

  • 技术报告,在2例主动脉病变患者中演示半分支技术。
  • 第一例为76岁女性,腹主动脉瘤腔内修复(EVAR)术后Ia型内漏。
  • 第二例为75岁男性,近肾动脉瘤。

主要发现

  • 第一例因EVAR主体短且病变向肾上延伸,选用带整合分叉的4分支装置,为肠系膜上动脉(SMA)和腹腔干(CT)规划2个半分支。
  • 第二例因主动脉直径小,为SMA和CT规划半分支。
  • 两例均采用全经股动脉入路并使用可调弯鞘。
  • 所有4个半分支均成功封堵动脉瘤,置入、半分支插管、桥接支架输送及密封均顺利。

关键数值与推荐

  • 半分支长度缩短,可提高包装密度并增大支架移植物直径。
  • 半分支填补了开窗不适合(主动脉扭曲)且标准内分支空间不足(直径小)的病变治疗空白。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe the semibranch as new tool to treat patients with thoracoabdominal, para- and juxtarenal aortic pathologies. TECHNIQUE: The technique is demonstrated in 2 patients with aortic pathologies. First, a 76-year-old woman with a type Ia endoleak after endovascular repair of abdominal aneurysm (EVAR). Due to the short mainbody of the EVAR and suprarenal extension of the pathology, a 4-branched device with integrated bifurcation was chosen. To realize a branched device in small diameters of the suprarenal aorta, 2 semibranches, for the superior mesenteric artery (SMA) and the celiac trunc (CT), were planned. The second patient, a 75-year-old man, had a juxtarenal aneurysm. Due to small diameters of the aorta, semibranches for the SMA and the CT were planned. In both cases, a total transfemoral approach was used with a steerable sheath. Placement, cannulation of the semibranch, forwarding of the bridging stentgraft, and sealing was uneventful. All 4 semibranches were successful in sealing the aneurysm. CONCLUSION: The semibranch is another tool in the armamentarium of the endovascular interventionalist, which can expand the range of patients that can be treated. Especially patients with small aortic diameter or short distances between target vessels with the same offspring angle can profit from the semibranch design.Clinical ImpactThe semibranch is a new tool to treat thoracoabdominal as well para- and juxtarenal aortic pathologies. Due to its reduced length, packaging density can be higher and diameter of the stentgraft can be larger. It closes the gap in pathologies where fenestration are not suitable (kinked aortas) and there is not enough space for standard inner branches (small diameters).

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Oberhuber A, Simonte G, Isernia G, et al. The Semibranch: A New Tool for Complex Aortic Pathologies. J Endovasc Ther. 2023. PMID: 38140760. doi:10.1177/15266028231219661

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。