文献速递外周动脉疾病

自动示波法踝臂指数测量诊断外周动脉疾病的准确性与可靠性

The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease.
PubMed 文献 · Ann Vasc Surg · 2023-10-31

研究纳入122例外周动脉疾病患者,随机顺序用示波法与多普勒法测量踝臂指数,评估示波法诊断的准确性与可靠性。以多普勒踝臂指数<0.9为诊断阈值时,示波法灵敏度57.81%、特异度95.18%,ICC为0.626(95%CI: 0.536-0.701)。作者认为示波法踝臂指数准确性及可靠性不满意,不宜作为临床疾病评估的替代方法,以1.00为阈值可提高诊断价值。

要点

  • 以多普勒踝臂指数<0.9为阈值,示波法灵敏度57.81%、特异度95.18%,ICC为0.626(95%CI: 0.536-0.701)。
  • 以1.00为阈值并将示波法误差结果视为异常时,高多普勒踝臂指数组灵敏度提高至88.05%,低组为81.42%。
  • 作者认为示波法踝臂指数准确性及可靠性不满意,不宜作为临床疾病评估的替代方法。

核心结论

  • 在动脉疾病患者中,示波法踝臂指数的准确性与可靠性不满意,不宜作为临床疾病评估的替代方法。
  • 以1.0作为示波法踝臂指数诊断外周动脉疾病的阈值可提高诊断价值。

研究设计与样本

  • 纳入介入放射科收治的122例外周动脉疾病患者,随机顺序用示波法与多普勒法测量踝臂指数。
  • 排除不确定结果后,对每条肢体比较多普勒与示波法踝臂指数。
  • 用组内相关系数评价可靠性,用受试者工作特征曲线与Bland-Altman法评价准确性与一致性。

主要发现

  • 122例患者共244条腿中,27条腿示波法结果不确定,4条腿示波法与足背动脉多普勒结果均不确定,2条腿无法耐受示波法袖带加压。
  • 以多普勒踝臂指数<0.9为诊断阈值,与高多普勒踝臂指数相比,示波法灵敏度57.81%、特异度95.18%,ICC为0.626(95%CI: 0.536-0.701),Bland-Altman法显示11/211(5.21%)个差值点位于95%一致性界限外。
  • 与低多普勒踝臂指数相比,示波法灵敏度50.66%、特异度98.31%,ICC为0.541(95%CI: 0.483-0.630),Bland-Altman法显示11/211(5.21%)个差值点位于95%一致性界限外。
  • 以1.00为诊断阈值并将示波法误差结果视为异常踝臂指数时,高多普勒踝臂指数组灵敏度提高至88.05%,低组为81.42%。

关键数值与推荐

  • 以多普勒踝臂指数<0.9为诊断阈值,与高多普勒踝臂指数相比,示波法灵敏度57.81%、特异度95.18%。
  • 以多普勒踝臂指数<0.9为诊断阈值,与低多普勒踝臂指数相比,示波法灵敏度50.66%、特异度98.31%。
  • 高多普勒踝臂指数组ICC为0.626(95%CI: 0.536-0.701),低多普勒踝臂指数组ICC为0.541(95%CI: 0.483-0.630)。
  • 以1.00为诊断阈值并将示波法误差结果视为异常时,高多普勒踝臂指数组灵敏度88.05%,低组81.42%。

临床怎么用

  • 作者认为示波法踝臂指数不宜作为临床疾病评估的替代方法。
  • 作者提出以1.0作为示波法踝臂指数诊断外周动脉疾病的阈值可提高诊断价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Comparing the accuracy and reliability of ankle-brachial index (ABI) measured by an oscillometric device with the Doppler method in peripheral arterial disease (PAD). METHODS: 122 patients admitted to the department of interventional radiology with PAD were studied. ABI was measured with the 2 methods in random order. After excluding the inconclusive results, Doppler ABIs were compared with the oscillometric ABIs in each limb, the reliability was evaluated by intraclass correlation coefficient (ICC), and the accuracy and consistency were assessed by receiver operating characteristic curves and Bland-Altman method. RESULTS: In 122 patients (244 legs), 27 legs got inconclusive oscillometric results, 4 legs got inconclusive oscillometric and inconclusive dorsalis pedis artery Doppler results, 2 legs had oscillometric cuff pressure intolerance. Using Doppler ABI <0.9 as a diagnostic threshold, compared with the high Doppler ABI, oscillometric method had a sensitivity of 57.81%, a specificity of 95.18%, the ICC was 0.626 (95% confidence interval [CI]: 0.536-0.701), Bland-Altman method showed 11/211 (5.21%) difference points outside the 95% limits of agreement. Compared with the low Doppler ABI, oscillometric method had a sensitivity of 50.66%, a specificity of 98.31%, the ICC was 0.541(95% CI: 0.483-0.630), Bland-Altman method showed 11/211 (5.21%) difference points outside the 95% limits of agreement. Using 1.00 as the diagnostic threshold and considering error oscillometric results as abnormal ABIs, the sensitivity improved to 88.05% with high Doppler ABI and 81.42% with the low. CONCLUSIONS: The accuracy and reliability of oscillometric ABI in patients with PAD is unsatisfied, which makes it not suitable as an alternative method in clinic disease assessment. Using 1.0 as the ABI oscillometric threshold for PAD diagnosis can improve the diagnostic value.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Fu G, Jiang R, Qian C, et al. The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease. Ann Vasc Surg. 2023. PMID: 37918661. doi:10.1016/j.avsg.2023.09.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。