最大收缩期加速度检测外周动脉疾病的诊断准确性
本回顾性队列研究在三级转诊医院纳入340例疑似外周动脉疾病患者(618条肢体),评估最大收缩期加速度(ACCmax)以计算机断层血管造影为参考标准的诊断性能。结果显示ACCmax在胫后动脉、胫前动脉和腓动脉的曲线下面积分别为0.953、0.984和0.893,在糖尿病或慢性肾脏病患者亚组分析中诊断准确性未下降。
要点
- ACCmax检测外周动脉疾病在胫前动脉的灵敏度94%、特异度97%,曲线下面积0.984。
- 胫后动脉灵敏度90%、特异度93%,曲线下面积0.953;腓动脉灵敏度86%、特异度89%,曲线下面积0.893。
- 在糖尿病或慢性肾脏病患者亚组分析中,ACCmax的诊断准确性未下降。
核心结论
- ACCmax检测外周动脉疾病表现出极好的诊断性能,且不受易发生中膜动脉钙化患者的影响。
研究设计与样本
- 回顾性队列研究,在三级转诊医院纳入年龄≥18岁、疑似外周动脉疾病且接受ACCmax测量以及腹主动脉和下肢计算机断层血管造影(参考标准)的患者。
- 共纳入340例患者(618条肢体),约40%患有糖尿病,30%患有慢性肾脏病。
- 收集胫后动脉、胫前动脉和腓动脉的ACCmax测量值,采用灵敏度、特异度、阳性似然比、阴性似然比和曲线下面积评估诊断性能。
主要发现
- 胫后动脉ACCmax检测外周动脉疾病的灵敏度为90%,特异度为93%,阳性似然比为12.83,阴性似然比为0.11,曲线下面积为0.953。
- 胫前动脉ACCmax的灵敏度为94%,特异度为97%,阳性似然比为32.06,阴性似然比为0.06,曲线下面积为0.984。
- 腓动脉ACCmax的灵敏度为86%,特异度为89%,阳性似然比为7.51,阴性似然比为0.16,曲线下面积为0.893。
- 在糖尿病或慢性肾脏病患者亚组分析中,ACCmax的诊断准确性未下降。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Diagnosing peripheral arterial disease (PAD) can be challenging owing to medial arterial calcification (MAC) in patients with diabetes mellitus (DM) and chronic kidney disease (CKD). Current bedside tests, such as the ankle-brachial index and toe-brachial index, are often insufficient. The maximal systolic acceleration (ACCmax) is a velocimetric Doppler-derived parameter and could be a new promising test in the diagnostic workup of these patients. The primary aim of this study was to evaluate the diagnostic performance of the ACCmax to detect PAD. METHODS: A retrospective cohort study was performed in a tertiary referral hospital. Patients ≥18 years old with suspected PAD who underwent ACCmax measurement(s) along with computed tomography angiography of the abdominal aorta and lower extremities (reference test) were eligible for inclusion. ACCmax measurements of the posterior tibial artery, anterior tibial artery and peroneal artery were collected. Diagnostic performance was assessed by using sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve (AUC). RESULTS: In total, 340 patients (618 limbs) were included. Approximately 40% suffered from DM and 30% had CKD. Diagnostic performance of the ACCmax to detect PAD for the posterior tibial artery showed a sensitivity of 90%, specificity of 93%, positive likelihood ratio of 12.83, and negative likelihood ratio of 0.11 (AUC, 0.953). For the anterior tibial artery, these results were 94%, 97%, 32.06, and 0.06 (same sequence as presented before) with an AUC of 0.984. The peroneal artery had a performance of 86%, 89%, 7.51, and 0.16, respectively (AUC, 0.893). Diagnostic accuracy of the ACCmax did not diminish in subgroup analysis for patients with DM or CKD. CONCLUSIONS: The ACCmax showed excellent diagnostic performance to detect PAD, independent of patients prone to medial arterial calcification.
引用
- Willems SA, Dolfing SG, van Wissen RC, et al. Diagnostic accuracy of the maximal systolic acceleration to detect peripheral arterial disease. J Vasc Surg. 2023. PMID: 37913945. doi:10.1016/j.jvs.2023.10.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。