文献速递主动脉疾病

编辑精选——光纤实时形状技术在血管腔内动脉瘤修复术中对侧肢体插管时的辐射剂量降低

Editor's Choice - Radiation Dose Reduction During Contralateral Limb Cannulation Using Fiber Optic RealShape Technology in Endovascular Aneurysm Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2023-11-03

该单中心、非随机回顾性比较研究将27例FORS引导的EVAR与27例常规透视引导的EVAR按性别、年龄和BMI 1:1匹配,比较对侧肢体插管的技术成功率、导航时间与辐射剂量。FORS组对侧肢体插管成功率为81%(22/27),在导航时间相等(p=.95)的情况下,累积空气比释动能、空气比释动能面积乘积和透视时间均显著低于常规组;完整手术的各项结局无显著差异。

要点

  • 27例FORS引导EVAR中22例(81%)使用FORS成功完成对侧肢体插管。
  • FORS组对侧肢体插管辐射剂量参数显著低于常规组:CAK p<.001、KAP p=.009、FT p<.001。
  • 两组导航时间相等(p=.95),完整EVAR手术结局无显著差异。

核心结论

  • 在标准EVAR中,使用FORS技术可显著降低对侧肢体插管期间的辐射剂量。

研究设计与样本

  • 非随机、回顾性比较研究,比较前瞻性收集的单中心FORS引导EVAR数据与常规透视引导EVAR队列数据。
  • 共27例FORS引导病例按性别、年龄和BMI与27例常规(仅透视)EVAR进行1:1匹配。
  • 主要关注FORS技术成功率以及对侧肢体插管期间的导航时间和辐射剂量(累积空气比释动能CAK、空气比释动能面积乘积KAP、透视时间FT),并研究完整EVAR手术的总手术时间和辐射剂量。

主要发现

  • 27例FORS引导病例中22例(81%)使用FORS成功完成对侧肢体插管。
  • FORS组所有辐射剂量参数均显著低于常规组:CAK p<.001、KAP p=.009、FT p<.001,且导航时间相等(p=.95)。
  • 完整手术结局比较未发现显著差异。

临床怎么用

  • 原文结论为在标准EVAR中对侧肢体插管时使用FORS技术可显著降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The increasing number of endovascular procedures has resulted in an increasing radiation burden, particularly for the treatment team. Fiber Optic RealShape (FORS) technology uses laser light instead of fluoroscopy to visualise the endovascular guidewire and catheters. These devices can be used during the navigational part of procedures, such as cannulation of the contralateral limb (CL) in endovascular aneurysm repair (EVAR). The aim of this study was to describe the effect of using FORS on radiation dose during CL cannulation in standard EVAR. METHODS: This was a non-randomised, retrospective comparison study of prospectively collected, single centre data from FORS guided EVAR compared with a conventional fluoroscopy only guided EVAR cohort. A total of 27 FORS guided cases were matched 1:1 based on sex, age, and body mass index (BMI) with 27 regular (fluoroscopy only) EVARs. This study primarily focused on (1) technical success of FORS and (2) navigation time and radiation dose (cumulative air kerma [CAK], air kerma area product [KAP], and fluoroscopy time [FT]) during cannulation of the CL. In addition, overall procedure time and radiation dose of the complete EVAR procedure were studied. RESULTS: In 22 (81%) of the 27 FORS guided cases the CL was successfully cannulated using FORS. All radiation dose parameters were significantly lower in the FORS group (CAK, p < .001; KAP, p = .009; and FT, p < .001) for an equal navigation time (p = .95). No significant differences were found when comparing outcomes of the complete procedure. CONCLUSION: Use of FORS technology significantly reduces radiation doses during cannulation of the CL in standard EVAR.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Klaassen J, Hazenberg CEVB, Bloemert-Tuin T, et al. Editor's Choice - Radiation Dose Reduction During Contralateral Limb Cannulation Using Fiber Optic RealShape Technology in Endovascular Aneurysm Repair. Eur J Vasc Endovasc Surg. 2023. PMID: 37925100. doi:10.1016/j.ejvs.2023.10.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。