应用Anaconda覆膜支架行开窗主动脉瘤修复术后第一年随访中肾动脉与内脏动脉的构型:一项基于心电图门控CTA的前瞻性纵向多中心研究
这项前瞻性多中心观察性队列研究纳入21例复杂腹主动脉瘤患者,接受开窗Anaconda支架及Advanta V12桥接支架的FEVAR,术前行心电图门控CTA并在出院、7周和12个月随访。结果显示肾动脉分支角度在FEVAR后显著增大趋向垂直于主动脉,而内脏分支角度无显著变化;左肾动脉平均动态曲率从术前3.0 m-1降至12个月随访1.9 m-1。其余研究变量在本队列中未见随时间变化,结论认为除肾分支角度增大外构型稳定至12个月随访,且本队列中无 apparent 临床后果。
要点
- 肾动脉分支角度在FEVAR后显著增大趋向垂直于主动脉,右肾动脉从术前中位60.9°增至12个月随访94.4°(p=0.001)。
- 左肾动脉分支角度从术前中位63.7°增至12个月随访94.3°(p<0.001),而内脏分支角度无显著变化。
- 左肾动脉平均动态曲率从术前3.0 m-1降至12个月随访1.9 m-1(p=0.027),其余变量未见随时间变化。
核心结论
- 使用开窗Anaconda支架和球囊扩张式Advanta V12桥接支架对复杂腹主动脉瘤行FEVAR,除肾分支角度增大趋向垂直于主动脉外,构型稳定至12个月随访,且本队列中无 apparent 临床后果。
研究设计与样本
- 前瞻性多中心观察性队列研究,纳入21例复杂腹主动脉瘤患者(9例近肾型/6例肾旁型/3例内脏旁型/1例IV型胸腹主动脉瘤),接受开窗Anaconda支架及Advanta V12桥接支架治疗,术前行心电图门控CTA并在出院、7周和12个月随访。
主要发现
- 右肾动脉分支角度从术前中位60.9°(IQR=44.2-84.9°)增至12个月随访94.4°(IQR=72.6-99.8°),p=0.001。
- 左肾动脉分支角度从术前中位63.7°(IQR=55.0-73.0°)增至12个月随访94.3°(IQR=68.2-105.6°),p<0.001。
- 内脏分支角度无显著变化。
- 左肾动脉平均动态曲率从术前3.0 m-1(IQR=2.2-3.8 m-1)降至12个月随访1.9 m-1(IQR=1.4-2.6 m-1),p=0.027。
- 其余研究变量在本队列中未见随时间变化。
临床怎么用
- 作者建议仔细考虑肾分支角度增大和显著的几何形态改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability. DESIGN: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups. METHODS: Fenestrated endovascular aortic aneurysm repair stability was assessed considering the following variables: branch angle as the angle between the aorta and the target artery, end-stent angle as the angle between the end of the bridging stent and the native artery downstream from it, curvature and tortuosity index (TI) to describe the bending of the target artery. Body-bridging stent stability was assessed considering bridging stent flare lengths, the distances between the proximal sealing stent-ring and fenestrations and the distance between the fenestration and first apposition in the target artery. RESULTS: Renal branch angles significantly increased after FEVAR toward a perpendicular position (right renal artery from median 60.9°, inter quartile range [IQR]=44.2-84.9° preoperatively to 94.4°, IQR=72.6-99.8°, p=0.001 at 12-month follow-up; left renal artery [LRA], from 63.7°, IQR=55.0-73.0° to 94.3°, IQR=68.2-105.6°, p<0.001), while visceral branch angles did not. The mean dynamic curvature only decreased for the LRA from preoperative (3.0, IQR=2.2-3.8 m-1) to 12-month follow-up (1.9, IQR=1.4-2.6 m-1, p=0.027). The remaining investigated variables did not seem to show any changes over time in this cohort. CONCLUSIONS: Fenestrated endovascular aortic aneurysm repair for complex AAAs using the Anaconda fenestrated stent-graft and balloon-expandable Advanta V12 bridging stents demonstrated stable configurations up to 12-month follow-up, except for increasing renal branch angles toward perpendicular orientation to the aorta, yet without apparent clinical consequences in this cohort.Clinical ImpactThis study provides detailed information on the cardiac-pulsatility-induced (dynamic) and longitudinal geometry deformations of the target arteries and bridging stents after fenestrated endovascular aortic aneurysm repair (FEVAR) up to 12-month follow-up. The configuration demonstrated limited dynamic and longitudinal deformations in terms of branch angle, end-stent angle, curvature, and tortuosity index (TI), except for the increasing renal branch angles that go toward a perpendicular orientation to the aorta. Overall, the results suggest that the investigated FEVAR configurations are stable and durable, though careful consideration of increasing renal branch angles and significant geometry alterations is advised.
引用
- Simmering JA, Koenrades MA, Slump CH, et al. Renal and Visceral Artery Configuration During the First Year of Follow-Up After Fenestrated Aortic Aneurysm Repair Using the Anaconda Stent-graft: A Prospective Longitudinal Multicenter Study With ECG-Gated CTA Scans. J Endovasc Ther. 2023. PMID: 37933525. doi:10.1177/15266028231209929
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。