医师改良单开窗腔内缝合主动脉瘤修复术(FESAR)用于急诊近肾腹主动脉瘤修复
本文描述一例85岁不适合开放手术的症状性近肾腹主动脉瘤患者,采用EndoAnchor锚定联合医师改良单开窗支架完成腔内修复。术后30天和9个月CT血管造影确认支架位置正确且动脉瘤完全隔绝。作者认为在极高度选择的病例中,该技术可利用现成器械急诊处理复杂主动脉瘤。
要点
- 85岁症状性近肾腹主动脉瘤患者,不适合开放修复,采用医师改良单开窗Endurant支架联合EndoAnchor完成腔内修复。
- 术后30天和9个月CT血管造影确认支架位置正确、动脉瘤完全隔绝。
- 作者认为在极高度选择的病例中,该联合技术可利用现成器械急诊处理复杂主动脉瘤。
核心结论
- 在极高度选择的病例中,EndoAnchor与医师改良单开窗支架联合可能有助于利用现成器械治疗复杂急诊主动脉瘤。
研究设计与样本
- 技术报告,描述一例85岁症状性近肾腹主动脉瘤患者的腔内治疗。
主要发现
- 患者肾下颈长0.6 cm、直径23 mm;使用28 mm直径Endurant主动脉袖套改良为左肾动脉单开窗并加直径缩小束带,重新装入鞘管后释放。
- 左肾动脉以7F鞘管插管并撤出约束导丝;因袖套右侧颈长最短,在该侧用2枚EndoAnchor将支架锚定于主动脉壁。
- 左肾动脉置入支架并扩口;远端医师改良(无自由流)分叉型Endurant支架与近端袖套重叠,并用6枚EndoAnchor稳定。
- 术后30天和9个月CT血管造影确认支架位置正确且动脉瘤完全隔绝。
临床怎么用
- 作者认为在极高度选择的病例中,EndoAnchor与医师改良单开窗支架联合可能有助于利用现成器械急诊治疗复杂主动脉瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To describe the endovascular treatment of a symptomatic juxtarenal abdominal aortic aneurysm (JAAA) using a combination of endoanchors (Heli-FX EndoAnchor, Medtronic, Minneapolis, Minnesota) and a physician-modified single-fenestrated endograft. TECHNIQUE: An 85 year-old patient unfit for open aortic repair presented for a symptomatic JAAA, characterized by an infrarenal neck with 0.6 cm in length and 23 mm in diameter. A 28 mm-diameter Endurant aortic cuff (Medtronic, Minneapolis, Minnesota) was modified with a single fenestration for the left renal artery (LRA) and diameter-reducing tie, then re-sheathed and deployed. The LRA was cannulated with a 7F sheath and the constraining wire was withdrawn. Being the shortest neck length on the right side of the cuff, the endograft was anchored to the aortic wall on this side with 2 endoanchors. The LRA was stented and flared, then a distal physician-modified (without free-flow) bifurcated Endurant graft (Medtronic, Minneapolis, Minnesota) was overlapped with the proximal cuff and stabilized with 6 endoanchors. Correct positioning with complete aneurysm exclusion was confirmed with a 30 day and 9 month computed tomography angiograms. CONCLUSIONS: In extremely selected cases, association of endoanchors and single-fenestrated physician-modified graft may be useful to treat complex urgent aortic aneurysm using readily available devices.Clinical ImpactThis technical note demonstrates the feasibility of a single-fenestrated physician-modified Endurant endograft deployed in combination with endosuture fixation (FESAR), to urgently treat a juxtarenal aortic aneurysm unfit for open repair and not suitable for standard endovascular repair nor off-the-shelf endografts.
引用
- Piazza M, Squizzato F, James Bilato M, et al. Physician-Modified Single-Fenestrated EndoSuture Aneurysm Repair (FESAR) for Urgent Juxtarenal AAA Repair. J Endovasc Ther. 2023. PMID: 37990854. doi:10.1177/15266028231212131
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。