开发用于血管腔内腹主动脉瘤修复术中引导的人工智能工具
本研究训练并测试深度学习模型,用于在血管腔内动脉瘤修复(EVAR)术中识别覆盖最低肾动脉的「禁入」锚定区。模型使用来自单中心择期EVAR手术及开放获取来源的369张透视图像进行训练,采用10折交叉验证评估。模型交并比为0.43(±0.29),F1为0.53(±0.32),像素准确率0.97(±0.002),敏感度0.51(±0.34),特异度0.99(±0.001)。结论认为AI能有效识别支架释放的次优区域,需在其他机构数据集上验证并评估其预测最佳支架放置和临床结局的能力。
要点
- 深度学习模型可识别EVAR术中覆盖最低肾动脉的「禁入」锚定区。
- 模型交并比0.43(±0.29),F1为0.53(±0.32)。
- 像素准确率0.97(±0.002),敏感度0.51(±0.34),特异度0.99(±0.001)。
核心结论
- 人工智能可有效识别EVAR术中支架释放的次优区域。
- 进一步方向包括在其他机构数据集上验证模型,并评估其预测最佳支架放置和临床结局的能力。
研究设计与样本
- 研究训练并测试深度学习模型,以识别EVAR术中覆盖最低肾动脉的「禁入」锚定区。
- 图像来自单中心择期EVAR手术的透视图像及开放获取来源,由受训标注者标注「禁入」区。
- 采用10折交叉验证评估模型与人工标注的表现。
- 模型训练使用369张图像,来自110名不同患者/视频,其中18名患者/视频(44张图像)来自开放获取来源。
主要发现
- 主要结局交并比为0.43(标准差±0.29),F1为0.53(±0.32)。
- 次要结局像素准确率为0.97(±0.002),敏感度为0.51(±0.34),特异度为0.99(±0.001),阴性预测值为0.99(±0.002),阳性预测值为0.62(±0.34)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Adverse events during surgery can occur in part due to errors in visual perception and judgment. Deep learning is a branch of artificial intelligence (AI) that has shown promise in providing real-time intraoperative guidance. This study aims to train and test the performance of a deep learning model that can identify inappropriate landing zones during endovascular aneurysm repair (EVAR). METHODS: A deep learning model was trained to identify a "No-Go" landing zone during EVAR, defined by coverage of the lowest renal artery by the stent graft. Fluoroscopic images from elective EVAR procedures performed at a single institution and from open-access sources were selected. Annotations of the "No-Go" zone were performed by trained annotators. A 10-fold cross-validation technique was used to evaluate the performance of the model against human annotations. Primary outcomes were intersection-over-union (IoU) and F1 score and secondary outcomes were pixel-wise accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: The AI model was trained using 369 images procured from 110 different patients/videos, including 18 patients/videos (44 images) from open-access sources. For the primary outcomes, IoU and F1 were 0.43 (standard deviation ± 0.29) and 0.53 (±0.32), respectively. For the secondary outcomes, accuracy, sensitivity, specificity, NPV, and PPV were 0.97 (±0.002), 0.51 (±0.34), 0.99 (±0.001). 0.99 (±0.002), and 0.62 (±0.34), respectively. CONCLUSIONS: AI can effectively identify suboptimal areas of stent deployment during EVAR. Further directions include validating the model on datasets from other institutions and assessing its ability to predict optimal stent graft placement and clinical outcomes.
引用
- Li A, Javidan AP, Namazi B, et al. Development of an Artificial Intelligence Tool for Intraoperative Guidance During Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg. 2023. PMID: 37914075. doi:10.1016/j.avsg.2023.08.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。