升主动脉鼻锥环技术作为分支主动脉弓腔内移植物精准输送的补救措施且无需跨瓣
本文描述了一种右颈动脉-股动脉贯通导丝技术在分支胸主动脉弓腔内修复(B-TEVAR)中的应用,用于在极度迂曲的主动脉解剖中促进移植物输送,处理既往主动脉腔内移植物植入后的Ia型内漏。该技术在升主动脉形成环以保持导丝张力,使移植物鼻尖沿环指向头臂动脉而无需跨瓣,术后1个月CT血管造影确认部署正确。
要点
- 右颈动脉-股动脉贯通导丝结合升主动脉成环技术可辅助B-TEVAR中移植物通过迂曲解剖。
- 该技术使移植物鼻尖沿环指向头臂动脉而不跨越主动脉瓣。
- 术后完成造影及1个月CT血管造影确认移植物部署正确且无I/III型内漏。
核心结论
- 颈动脉-股动脉贯通导丝促进困难解剖中移植物输送在B-TEVAR中可行。
- 若移植物释放后需跨越主动脉瓣,存在可用的补救措施。
研究设计与样本
- 技术描述:在右颈总动脉与右股总动脉之间建立贯通导丝以促进困难的移植物输送。
- 在主动脉弓内于升主动脉形成环,使移植物到达目标位置而不失去导丝张力。
- 移植物释放后释放贯通导丝,分支按标准方式桥接。
主要发现
- 完成造影记录移植物正确部署且无I/III型内漏征象。
- 1个月CT血管造影确认正确部署。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To describe a right carotid-femoral through-and-through (T&T) guidewire technique during branched thoracic endovascular aortic arch repair (B-TEVAR) to facilitate endograft delivery in a very tortuous aortic anatomy for a type Ia endoleak (EL) of a previous aortic endograft implantation. TECHNIQUE: AT&T guidewire was established between the right common carotid artery and the right common femoral artery to facilitate a difficult endograft delivery. Once in the aortic arch, a loop in the ascending aorta was formed to allow the endograft to reach the desired position without losing tension on the guidewire. This maneuver allowed the T&T guidewire to be kept in place until the desired position was reached. The nose-tip of the endograft was curved over the looped guidewire pointing toward the innominate artery without crossing the valve. After endograft deployment, the T&T guidewire was released, and the branches were bridged in a standard fashion. Completion angiography documented correct deployment of the endograft and no sign of type I/III EL. The 1-month computed tomography angiography confirmed the correct deployment. CONCLUSION: Carotid-femoral T&T guidewire to facilitate endograft delivery in difficult anatomies can be feasible even in B-TEVAR. Possible bailout maneuvers are available if the aortic valve needs to be crossed after endograft delivery.Clinical ImpactEndovascular arch repair gains popularity as a valuable alternative, especially in patients considered unfit for open repair. A through-and-through (T&T) guidewire for endovascular arch repair with a landing zone in zone 0 according to Ishimaru is usually performed through the externalization of the femoral guidewire through a transapical access, but this may not always be feasible in frail patients. A right carotid-femoral though-and-through guidewire with a loop formation in the ascending aorta is proposed to achieve the support of a T&T wire to pass tortuous aortoiliac anatomies and access the ascending aorta without the need for aortic valve crossing.
引用
- Grandi A, Kölbel T, Rohlffs F, et al. Ascending Aorta Nose-Cone Loop Technique as Bail Out for Precise Branched Endovascular Aortic Arch Endograft Delivery Without Valve Re-Crossing. J Endovasc Ther. 2023. PMID: 37822242. doi:10.1177/15266028231201532
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。